Dissertation > Excellent graduate degree dissertation topics show

Calibration Method of characteristic parameters of the light-scattering particulate matter concentration measuring instrument

Author: YuXiao
Tutor: BianBaoMin
School: Nanjing University of Technology and Engineering
Course: Optical Engineering
Keywords: concentration measuring instrument parameter voltage channel calibration
CLC: O439
Type: Master's thesis
Year: 2007
Downloads: 217
Quote: 3
Read: Download Dissertation

Abstract


In order to realize measurement of aerosol mass concentration in real time byconcentration measuring instrument, the calibration of two characteristic parametersin the method is studied firstly. Through the measurement of suspended particulatematter sample, two characteristic parameters(equivalent parameter and sensitivitycoefficient) is obtained by the non-linear regression to Gauss-Newton method, therelation of the stability of characteristic parameter and concentration measuringinstrument range is further analyzed. The variety law of characteristic parameter isalso analyzed by minimization method, a method of equivalent parameter andsensitivity coefficient calibration is put forward, and it is used to calibrate theparameter of theory sample. It has been shown by experimentation that themeasurement relative error is lower than 10% between concentration measuringinstrument and SIDEPAK AM510 within lower than 5 mg/m~3. The propose ofcharacteristic parameter calibration method is also of great significance for onlinemeasurement realization of concentration measuring instrument.Secondly, the cost of concentration measuring instrument which contains 2048voltage channels is too high, so the voltage channel optimization problem is discussed.First the influence that the number of voltage channel exerts on measurementaccuracy and stability under uniformity partition is studied. Then the optimization ofvoltage channel division way is realized according to the characteristic of particlescattering signal voltage scope distribution, geometric proportion interval voltagechannel division way is used, the channel voltage interval is small in the low voltagetip, and remarkably increases in the high voltage tip. The result indicates thatnumerical value of mass concentration can attain measurement precision which is tall,and the relatively error of concentration measuring instrument and SIDEPAK AM510is less than percent of ten using four voltage channels. The conclusion offersacademic guidance for the design of particle counter’s circuit.

Related Dissertations

  1. Quantitative Analysis of Pyrolysis Component of Typical Low Volatile Coal of Chinese,TQ530.2
  2. Development of the On-Line Electronic Gauge for Crackshaft’s Axial Length Parameters,TH822
  3. The Technological Parameter Analysis and Influencing Factor Research on RUV4 Automobile Ignition Coils,U463.64
  4. Research on Testing and Analyzing Technology for Time Parameter of Aerospace Relay,TM58
  5. Research on Vector Control System of Induction Motor Based on DSP,TM346
  6. Research on Disease Related miRNA Mining Based on Protein-Protein Interaction Network,R341
  7. Research on the Optimization of Laser Triangulation Device,TH744.5
  8. Research on Direct Sequence Spread Spectrum Signal Detection and Parameter Estimation,TN914.42
  9. Modulation Pattern Recognition and Parameter Estimation for Ground Wave Radiation Sources,TN957.51
  10. Research on Structure Transition Technology for SMT,TP391.2
  11. The Research of 3D Human Motion Capture Based on Reference Points,TP391.41
  12. Camera Calibration and Position and Pose Detecting on Vision Measurement System of PCB,TP391.41
  13. Research on Predictive Control and Simulation of pH Value Based on the Confection Process of Sodium Nitrate,TP273
  14. Key Control Technique of Wafer Handling Robot,TP242.2
  15. Hot air drying characteristics of lettuce osmotic dehydration mass transfer kinetics and permeability,TS255.52
  16. Research on Puff Sleeve Model and Pattern Design of Women’s Clothes,TS941.2
  17. Study on Small Bank-based Constructed Wetland for Remediation of Polluted Water in City Stream,X703
  18. Study on Modeling Effects of Genotype and Sowing Date on Rice Prductivity,S511
  19. Study on the Relationship among Root System and the Shoot Dry Matter Accumulation and Yield from Winter Wheat Under Different Cultivation and Management Modes,S512.11
  20. Modeling Genotype by Climate Effect on Wheat Prductivity,S512.1
  21. The Research and Application of Software Reliability Test for User Right Management System,TP311.53

CLC: > Mathematical sciences and chemical > Physics > Optics > Applied Optics