Abstract


Power transformer is an important electrical power system equipment, especially330~500kV large transformer, which directly affect the operational status of the entire power network security and stability of the trunk. When a transformer fails, you need timely and accurate transformer removal of faults, so to protect the reliability of operation is directly related to the safe operation of the transformer. A large number of ABB’s REL511device used in the East China Power Grid, as a back-up distance of transformer protection. Actual operation of the device is often abnormal exit the operation, even false to export the accident leading to the transformer trip, resulting in a serious impact on the safe operation of the grid. It is necessary to the health of the device and defects hidden pooled analysis, and propose targeted to improve the design program. In order to study the current REL511protection devices operating conditions, the paper first configuration features of the large-scale transformer protection Background, detailed analysis of the main transformer has been the main protection, it also configure the backup distance protection. This article describes the REL511device characteristics, as well as the distance of the main transformer backup protection features. As in the dual-bus Connection mode, the voltage switching circuit is essential REL511devices collect voltage and voltage lockout circuit, transformer protection is different from the line intervals, generally not equipped with operative box, provided by the REL511protection device itself. This article draw on the research results of the secondary voltage switch circuit in the dual-bus Connection mode and the use of voltage REL511device to switch back to the road. This paper analyzes the East China Power Grid loss of pressure in different types of running REL511device locking manner, Found that the device due to the different stages of secondary voltage break blocking circuit design flaws, resulting in instability of the device running. During the analysis, combined with design features found in the actual operation of accident cases and different types of REL511devices, this article presents the targeted improvements and design practice has proven to be effective to avoid grid accidents.

Related Dissertations

  1. Research on a New Principle of the Distance Relay,TM773
  2. Analysis and Research on Impact of TCSC on the Protection of Transmission Lines,TM773
  3. The Characteristics of a New Type of Fault Current Limiter and Its Effect on Power System,TM471
  4. Research on Distance Protection of Series Compensated Lines,TM773
  5. The Research of HVDC Impact on the Relay Protection of ac Network and the Solution Measure,TM77
  6. Adaptive Distance Protection of UHV/EHV Transmission Line,TM773
  7. Research 110kv line distance protection based on traveling wave theory,TM755
  8. Develop the Experimental System of Relay Protection Based on Virtual Instrument Technology,TM774
  9. Analysis of Distance Protection for Asymmetrical Transmission Line,TM773
  10. A Research on Protection System of Distribution Network Including Inverter-based Distributed Generation,TM773
  11. The TCSC on the Impact of the Adjacent Line Distance Protection,TM773
  12. Research on Improved Apparent Impedance Algorithm Considering Influence of STATCOM on Distance Protection,TM773
  13. Radiation Dose Monitor and Protection of Close Contacts from Radiators after Implantation of Radioactive125I Seeds,R818.74
  14. Research of Protection Schemes and Their Application in the Quadruple Circuit Transmission Line,TM773
  15. Fault Position Identification and New Principle of Protection for Series Compensated Transmission Lines with SSSC,TM773
  16. Research on Application of Integrated Relay Protection in Low and Medium Voltage Substation,TM774
  17. Dual CPU architecture line protection research and development,TM774
  18. The Distance Protection Filtering Algorithm Studies of Ultrahigh Voltage Electrical Network,TM773
  19. Empirical Research on Chinese IPO Underpricing: with Respect to Systems, Market Conditions and Firms’ Registering Places,F224
  20. Research on the Pilot Protection and the Fault Phase Selection for Double Circuit Lines on the Same Tower,TM773

CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Power system protection > Protection of components
© 2012 www.DissertationTopic.Net  Mobile