Dissertation > Excellent graduate degree dissertation topics show
Study on Dynamic Electrocardiogram Monitoring System and Electrocardiosignal Processing Method
Author: KongFanXue
Tutor: LiShiGuang
School: Shandong University of Science and Technology
Course: Detection Technology and Automation
Keywords: Dynamic electrocardiogram USB telemonitoring baseline drift waveform detection
CLC: TH772.2
Type: Master's thesis
Year: 2011
Downloads: 22
Quote: 0
Read: Download Dissertation
Abstract
The incidence of heart disease is increasing annually and there is a lowering age trend with the quickened circadian rhythm and intensifying competition. The heart disease is seriously imperiling human health and life. The dynamic electrocardiogram monitoring system can make continuous records of the 24-hour electrocardiosignals and provide real-time monitoring. And, patients can be timely diagnosed and treated based on the heart abnormalities that are automatically analyzed. This system is playing very important roles, especially in diagnoses of the sudden, transient arrhythmia, ischemia myocardial and so on.This paper represented a perfect dynamic electrocardiogram monitoring system capable of electrocardiosignal record, data storage, dynamic display, automatic analysis, and telemonitoring. It adopted the low-power-consumption, high-performance microcontroller STM32F103ZE based on the Cortex-M3 ARM core. Ample peripherals of the chip helped to reduce hardware costs. During the data acquisition, electrocardiosignals were collected by 10 electrodes fixed on body surface and 12 combined leads, and then were converted into digital signals by the analog-to-digital converter of STM32F103ZE after two-stage amplification. The 8G-byte NAND flash memory K9NCG08U5M served to the storage of 24-hour electrocardiogram data. Afterwards, electrocardiogram data were transferred to the upper monitor by the USB high-speed data transmission. Then, the waves were dynamically display, and the diagnostic information was acquired. The analyses of electrocardiogram data and diagnoses of abnormities were automatically completed. The wireless communication module based on GPRS realized the telemonitoring so that the user could be supplied with real-time monitoring, routine examination, daily health care and other services. At the same time, the user could be timely rescued in emergencies.This paper detailed on the electrocardiosignal processing method around two aspects:the electrocardiosignal preprocessing and waveform detection. The improved Levkov was chosen to filter out the 50Hz power-line interference. An algorithm based on PID adjustment for dynamic electrocardiosignal baseline drift removal was put forward, and had played an excellent part in practice. As for the electrocardiosignal waveform detection, it adopted the improved differential threshold method for localization of R-waves, and the improved Tompkins differential method for detection of QRS complex. The MATLAB simulation results using records from MIT-BIH arrhythmia database account for the simplicity, practicability and high accuracy of both above methods so that requirements of the real-time analysis of electrocardiosignal could be met.Several model machines with leads that reserved for our special use had been developed. Simulation and clinical trial results indicated the dynamic electrocardiogram monitoring system had high reliability and stability. And the analysis and diagnose of abnormities could be automatically completed according to the accurate electrocardiosignal diagnostic information.
|
Related Dissertations
- Design of Electronicalcontrol System for Electronic Jacquard Knitting Machine,TS183
- Research on the Integrated Grating Subdividing Digital Display Device Based on DSP,TH822
- Development of 3-Dimensional Scanning Probe Data Acquisition System Based on DSP,TP274.2
- Development of Inductance Sensor Data Acquisition System Based on FPGA,TP274.2
- Research and Design of Multi-Functional Wireless Mouse,TP334.2
- Multi-frequence Weak Signal Acquisition and Processing System Research and Design,TN911.23
- The Usb-based Virtual Storage on the mini6410,TP333
- FPGA-based USB data encryption and decryption system,TP309.7
- Infrared focal plane arrays based on USB2.0 data acquisition system,TP274.2
- Flash chip data recombinant technology research,TP333
- PBOC2.0 specification based smart card reader design and application development,TN409
- Comparative Analysis of Dynamic Electrocardiogram and Coronaryarteriography in Diagnosing CHD,R541.4
- USB2.0 device controller design,TP336
- USB Interface Circuit Based on Single Chip and Its Application in Data Communication,TP273
- Miniature mobile storage for desktop Linux System Research and Implementation,TP333.2
- PXI-based communications chip low - cost test solutions,TN407
- Development of the Test System,O572.212
- Hydraulic Turbine Governing System Testing Device Research and Implementation,TV734.1
- A Distributed Routing Algorithm for L-PLC Network and the Design of Management Platform Based on LonWorks,TM73
- The Development of Automobile Braking Performance Test System Based on CAN Bus,U467.4
CLC: > Industrial Technology > Machinery and Instrument Industry > Instruments, meters > Medical and health devices > Medical electrical machinery > Electronic equipment
© 2012 www.DissertationTopic.Net Mobile
|