Abstract
|
In this thesis, the author firstly introduces some concepts concerning time and frequency, then describes principle of the up-to-now most precise Laser Cooling - Cesium Atomic Fountain Clock and its running process, also the basic knowledge of semiconductor lasers and laser frequency stabilizations.According to the demands of the Laser Cooling - Cesium Atomic Fountain Clock and realizing the shortage, which needs to be improved, in the original laser frequency stabilization system, the author analyzes the basic technology that was used in the new system, and then presents a new frequency stabilization technique of External Cavity Diode Lasers (ECDL): AOM Frequency Jump Saturated Absorption - Digital Lock.In the third chapter, the author describes the design process of the new technique. The optical part uses a pump-probe and reference light configuration. The two beams are detected by two photodiodes. The outputs of the photodiodes pass two-way I/V converters and an analog subtract device to get the saturated absorption signal from which major part of the Doppler background is removed. The microcontroller then sets the frequency driving AOM to let the shifted optical frequency to jump alternatively to either side of the desired saturated absorption peak. The difference of the signals on two sides is fed into a digital PI controller, and the output of the controller serves the ECDL to lock its frequency to the desired central frequency of the saturated absorption.Beat experiments with two sets of stabilized ECDL systems demonstrated that a frequency stability of 1.1E-10/1s and a frequency reproducibility of 6.3E-11 have been achieved with this new stabilization technique. In addition this system can re-lock automatically in 3 seconds after unlocked by external disturbances, such as acoustic or mechanical, and has realized a sub-continuous lock of 3 weeks. This stabilized ECDL system has met the requirements of the Cs fountain clock under construction.
|
Related Dissertations
- A Study on the Metrology Knowledge in Wu Jing Zong Yao,TB9
- Research on Combined Large-scalemetrology System,TH711
- Research and Design on Distributed Metrology Management System of Aerospace Manufacturing Industry,TP311.52
- Study of Digital Speckle Photography and Spatial Modulation for Electronic Speckle Pattern,TN761
- Testing for the Relationships and Affecting Effects between Nominal and Real Variables,F224
- Study on Key Techniques of Precision Portable Vision Metrology,TP391.41
- Study of the Key Technologies for Temperature Measurement and Control in Large-Scale Metrology,TH811
- A Statistical Analysis of Core Papers Published and Papers Included by SCI(E) by the First Affiliated Hospital of Soochow University from 2004-2008,G353.1
- Research on and Measure of Transmyocardial Laser Revascularization,TP29-AI
- Technology Economy System Integration Research of Social Development Vulnerable,F062.4
- The New Method of Nano-Metrology and the Development of Dual Imaging Unit Atomic Force Microscope,TH742.9
- Metrological Analysis of Documents on Hospital Management in Anhui Province and Its Implication to Hospital Management Innovation Research,R197.3
- Study of Spatial Carrier Modulation and System for Electronic Speckle Pattern,O438
- Metrology Analysis of Track and Field Scientific Research Thesis in Sports Key Periodicals of Our Country,G353.1
- New Compilation of Historical Materials Science and Technology in Kangxi’s Chronicle the Research on Its Metrology,N092
- Equations of Propagation of Uncertinty on ITS-90 and on Radiation Interpolation Scales,O551.2
- The Research of Metrology in Tang Dynasty,TB9
- Spectroscopy of Several Kinds of Natural Chinese Traditional Medicine,R284
- Fabrication of AFM Carbon Nanotube Probe and Its Metrology Properties Study,TB383.1
- Chinese Medicine’s Patterns of Cirrhosis and Drug Clinical Application the Discussion of the Relevant Document of Metrology,R259
CLC: > Industrial Technology > Radio electronics, telecommunications technology > Photonics technology,laser technology > Laser technology, the maser > Laser
© 2012 www.DissertationTopic.Net Mobile
|