Dissertation > Excellent graduate degree dissertation topics show
Detect Principle Analysis for the Line-to-ground Fault Indicator Base on Signal Injection
Author: ChengHaiBin
Tutor: ChangXianRong;WangDongHai
School: North China Electric Power University (Hebei)
Course: Electrical Engineering
Keywords: Grounding line Fault Indicator Zero-sequence current 5th harmonic Signal injection method
CLC: TM862
Type: Master's thesis
Year: 2009
Downloads: 124
Quote: 0
Read: Download Dissertation
Abstract
|
The single-phase ground fault line selection and positioning principle for single-phase distribution network fault line selection and positioning difficulties , while analysis of the advantages and disadvantages of commonly used single-phase ground fault detection device . Small current grounding system , single- phase ground fault , the fault signal itself is weak , vulnerable to electromagnetic interference and harmonic pollution , resulting in signal distortion , these have a direct impact on the selectivity of the line selection and accurate even cause the selecting device malfunction . Combined with the actual situation of the work with reference to the actual characteristics of the various devices , line selection and positioning device selection signal injection method as with grid single-phase ground fault detection device , the more successful solution to the single-phase ground in distribution network fault location difficult problem.
|
Related Dissertations
- Research on Noise Reduction for Zero Sequence Current in Compensated Neutral Grounded Systems,TM862
- Research of the Fault Detection and Recovery System of Puyang Power Distribution Network,TM862
- Discussion of Incorrect Action of Zero-sequence Current Protection in Low Resistance Grounding System in Dongguan 10kV Power Grid,TM862
- Study on the Transient Zero Sequence Characteristic and Fault Line Detection of Single Phase-to-ground Fault in Small Current Neutral Grounding System,TM862
- Design of Distributed System of Fault Line Selection and Power Quality Monitoring in Non-effective Grounded Network,TM862
- Research and Implementation of the ADE7758-Based Power System Monitoring-Meter,TM933.4
- Study of Multipulse Rectification Based on Tapped Inter-Phase Reactor,TM461
- The Research on Harmonics Characteristics of Single-phase Nonlinear Loads in Low Voltage Distribution System Base on Experiments,TM711
- The Research and Realization on Fault Location Based on Pulse Signal Injection Method for Distribution Networks with Single Grounding Phase,TM862
- Studies on Complicated Distribution Network Fault Location Method,TM727
- The Study and Application of Automatic Fault Location System in the Distribution Network,TM76
- The Experiment Study of Different Grouding Based on Cable Network,TM862
- The Research on Arc Suppression Coil and Line Selection Control Technology in Distribution Network,TM862
- Research on the Fault Line Selection Device for Neutral Indirectly Grounded System Based on Transient Signal,TM862
- Research of the Signal Generator for Fault Location in Non-solidly Earthed Network,TM862
- The Theory Improvement of the Earth Fault Detectors in Non-Effectively Grounding Neutral System,TM862
- The Study of Fault Detection before Switching on,TM762.2
- Research on Combine Arc Suppression Coil with Shunt Reactor,TM475
- Study of Making Zero Sequence Current in Distribution Networks with Two Phases’ Current Transformers,TM862
- Study on Fault Location Method for Single-Phase-to-Ground Fault of Small Current Grounding System,TM862
- New Line-selection Methods for Single Phase Grounding Fault in Distribution Networks with Two Phase’s Current Transformers,TM862
CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage protection devices
© 2012 www.DissertationTopic.Net Mobile
|