Dissertation > Excellent graduate degree dissertation topics show
Studies on Microfluidic Chip Analysis Systems with Gas Diffusion Separation and Reflected Photometric Detection
Author: DangGuo
Tutor: XuZhangRun
School: Northeastern University
Course: Analytical Chemistry
Keywords: microfluidic chip PTFE membrane gas diffusion separation reflected photometric detection ammonium ion
CLC: O657.3
Type: Master's thesis
Year: 2009
Downloads: 27
Quote: 0
Read: Download Dissertation
Abstract
|
The research of microfluidic chip-based sample pretreatment has emerged as an active area in the field of micro total analysis systems (μTAS). Although gas diffusion separation is a powerful and popular method for sample pretreatment in conventional flow injection systems, there were relatively few studies about it applied in gas diffusion separation in microfluidic chip systems. A microfluidic chip based on gas diffusion separation of small size, high diffusion efficiency, simple structure and low cost was developed in this work. Poly(tetrafluoroethylene) (PTFE) membrane was used as gas-permeable membrane. A piece of pH paper covalently bounded acid-base indicator was fixed into the micro acceptor channel. The bounded acid-base indicator demonstrated several advantages, such as repetitive utilization of reagents and reduced reagent dilution. Therefore, a microfluidic chip analysis system integrated with gas diffusion separation and reflected photometric detection was built.In the first chapter, the related techniques of membrane separation in flow injection analysis systems, the types of microfluidic chips based on gas diffusion separation and the techniques of optical detection for micofluidic systems were reviewed. The purpose and design of this work were presented.In the second chapter, a three-layer microfluidic chip analysis system integrated with gas diffusion separation and reflected photometric detection was presented. In this three-layer structure, PTFE membrane was used as the gas-permeable, which was bonded in the middle of poly(dimethylsiloxane) (PDMS) layers—reaction channel and acceptor channel. Reflected photometric detection was achieved by fixing a piece of pH paper bounded acid-base indicator into the micro acceptor channel as the reflected photometric detection module. A micro-syringe pump was used for driving fluids. The slotted-vial array sample introduction system was employed for sampling, and automated sample introduction and change were achieved. NH4+ was used as a model analyte, and the related parameters were optimized. A precision of 1.0% RSD (n=7) was achieved with a detection limit of 0.30 mmol/L NH4+(3a) and sample consumption of 0.67μL for each assay. The system was applied for the detection of ammonium ion in industral wastewater, lake water and urine sample.The microfluidic chip integrated with gas diffusion separation and reflected photometric detection reduced both the bulk of the analysis system and the consumption of the samples and the reagents. The system can be applied for analysing biochemistry samples which are expensive and rare. If the sensitivity can be improved, the system is promisingly adequate to detect ammonium ion in blood with high speed and low consumption.
|
Related Dissertations
- Study on Removal-Effect of Domastic Sewage Containing Typical PPCPs in Membrane Bioreactors and Influencies on MBR,X703
- Droplet Microfluidic Chip for Investigation of Enzyme Activity and Encapsulation of Human Cells,Q503
- Investigation on Cell Synchronous Calcium Oscillations Based on Microfluidic Chip,Q25
- Microfluidic Chip-Based Cell Deformability Analysis System Using Scattering Light Detection,R319
- Study on a Method Based on Microfluidic Chip for Cell Metabolic Fingerprinting Visualization,Q2-3
- A Microfluidic Chip-based Spatial Temperature Gradient Capillary Electrophoresis System for DNA Mutation Detection,Q523-3
- Establishment and Characterization of Chip Free Flow Electrophoresis System,O657.8
- Studies on Sequential Injection Spectrophotometry for the Determination of TOC and Molybdenum in Environmental Water,X832
- Hydrated ammonium ions and sulfate ions systems theory,O641.1
- On-chip Cell Migration Assay for Quantifying the Effect of Ethanol on MCF-7 Human Breast Cancer Cells,R737.9
- Wetting effect on dielectric manipulation of microdroplets,TN492
- Study of the Combination of Microfluidic Chip and Raman Tweezers,Q6-33
- Fabrication of Opto-microfluidic Chips for Cell Counting,TH776
- Human thrombin microfluidic chip electrochemical detection,Q55-3
- Injection Compression Molding and Visualization Research of Microfluidic Chips,TQ320.662
- Design and Application of Integrated Microfluidic Chip for Phase Change Detection in Microscale,TN492
- The Research of Fabrication Process of PMMA Electrospray Chip,TN405
- Pump-free Negative Pressure Sampling Device for Rapid Sample Loading and Nonaqueous Electrophoresis-chemiluminescence on a Microchip,O657.3
- Studies on the Fabrication of Integrated PS Microfluidic Chips for ESI-MS,TN492
- The paper microfluidic chip electrophoresis - direct chemiluminescent imaging technology combined with human serum protein,R446.1
- Functionalization and Application of Microfluidic Chips of Cyclic Olefin Copolymer,TN492
CLC: > Mathematical sciences and chemical > Chemistry > Analytical Chemistry > Instrument analysis ( physics and physical chemistry ) > Photochemical analysis ( spectral analysis method)