Dissertation > Excellent graduate degree dissertation topics show
Conductive polymer synthesis and biological sensors
Author: JiangYan
Tutor: ZuoJinQing
School: Yangzhou University
Course: Physical and chemical
Keywords: Polyaniline film Response current Enzyme biosensor Conducting polymers Ionic liquids AC impedance Enzyme sensor Enzyme-catalyzed reactions Apparent Michaelis constant Sensor research
CLC: TP212.3
Type: Master's thesis
Year: 2007
Downloads: 153
Quote: 2
Read: Download Dissertation
Abstract
|
1. Studies on Synthesis and properties of uniform and Ordered Polyaniline Nanoparticles in the Magnetic FieldIn this paper, the uniform and ordered polyaniline nanoparticles with the average diameter about 95 nm were electropolymerized in solution containing 0.2 mol dm-3 aniline and 1.2 mol dm-3 HCl using the method of constant potential at 0.7 V in the presence of magnetic field (780 mT). Effects of the material of substrate and time on properties of polyaniline film were investigated. The experimental results show the magnetic field has orientation effect on aniline polymerization. Distinct scanning electron microscope (SEM) morphologies show polyaniline nanoparticles can be formed in the presence of the magnetic field. The CV and AC impedance results indicate the magnetic field makes the polymer film redox current larger and the charge transfer resistance (Rct) smaller. The nanoparticles were characterized by FTIR spectra, UV-Vis spectra.2. Selective Uricase Biosensor Based on Polyaniline Synthesized in Ionic LiquidThe selective uricase biosensor prepared with electroactive polyaniline (PANI) at high pH is firstly reported in this paper. Effects of electroactive interferents, such as acetaminophen, glutathione, l-cysteine and ascorbic acid on the current response of PANI-uricase biosensor were examined in the presence of their physiological normal levels with uric acid concentration at 0.5 mmol dm-3. These well-known interferents have been shown to have no measurable effect on the biosensor’s current response. In the range from 0.20 to 0.50 V, the current response increased with increasing potential. In the wide pH range from 2 to 12, current response increased with increasing pH, and the optimum pH was not appearing. We suggested the reason why the optimum pH of the PANI-uricase biosensor does not appear. The relationship between current response and uric acid concentration is good linear in the range from 1.0×10-3 to 1.0 mmol dm-3. The Michaelis–Menten constant Km’ is 7.83 mmol dm-3 and the maximum current response imax is 58.07μA. The current response of this biosensor increased with increasing temperature and Ea is 40.18 kJ mol-1 in the B–R buffer. The biosensor was characterized with FTIR, UV-Vis spectra and AC impedance.3. Glucose Biosensor Based on Electroactive Polyaniline at High pHThe use of highly conducting and electroactive polyaniline (PANI) at high pH as substrate to immobilize glucose oxidase is firstly reported in this paper. It is found the biosensor has a larger response current compared with biosensors prepared with control PANI synthesized in proton acid solution. In the range from 0.35 to 0.70 V, the response current increased with the increasing potential. In the wide pH range from 3.0 to 11.0, the response current first increased with the increasing pH, then decreased, and the maximum response current occurred at about pH 8.0. The relationship between response current and the glucose concentration is good linear in the range from 0.005 to 10.0 mmol dm-3. The Michaelis–Menten constant Km’ is 31.59 mmol dm-3 and the maximum response current imax is 21.28μA. The response current of this biosensor increased with the increasing temperature, and Ea is 32.58 kJ mol-1 in the B–R buffer. The biosensor was characterized with FTIR, UV-Vis spectra and AC impedance.
|
Related Dissertations
- Synthesis of Benzimidazolium Ionic Liquids and Their Application in Extraction Separation,O626.23
- Electropolymerization and Electrochromic Properties of Conducting Polymers,O631.3
- Study on Dehydration of tert-Butyl Alcohol Catalyzed by Functionalized Ionic Liquid,O643.32
- Studies on the Aggregation and Microstructure of Imidazolium Ionic Liquids in Solutions,O645.1
- Imidazolium ionic liquids selective electrode and its research activity coefficient,O646
- Benzothiazole - pyrimidine nucleoside hybrid body and pyrone and pyrimidine synthesis of bicyclic nucleoside,O626
- An ionic liquid to red carp immunotoxicity,S917.4
- Imidazolium ionic liquids Thermal Analysis,O626.23
- Synthesis of t- butyl alcohol using tert-butylbenzene, the catalyst selection and research,TQ241.1
- Synthesis, Electrical Properties and Applications of (La1-xSrx)2(Mo1-yGay)2O9-α,TM911.4
- Study on the Surface and Interface Properties of Room Temperature Ionic Liquids,O647.1
- Functional Br (?) Nsted acidic ionic liquid catalytic synthesis of cyclic carbonate reactivity,O643.32
- The Study on the Electrical and Optical Properties of Sm3+ Doped CeO2 Ion Conductor with Different Dopant Concentration,TM911.4
- Synthesis and Morphology Control of Tin Oxide,O614.432
- The Application of Ionic Liquids in Petroleum Products Processing,TE624.55
- Investigation of Ionic Liquids as Solvent for Extractive Separation of Benzene and Cyclohexane,TQ202
- Studies on the Heterogeneous Catalysts for the Cycloaddtion of Carbon Dioxide and Epoxides,O643.32
- The Applications and Prospect of Ionic Liquids in Electrochemistry Field as Electrolyte,O646
- Compatibility Study of Interface between Na~+ Conductive Ceramic and Na,TQ174.1
- Screening Ionic Liquid as Solvents for Capturing CO2 Based on Molecule Simulation,X701
- Synthesis and Surface-active Properties of Novel Quaternary Ammonium Salt Gemini Surfactants,TQ423
CLC: > Industrial Technology > Automation technology,computer technology > Automation technology and equipment > Automation components,parts > Transmitter ( converter),the sensor > Biological sensors,medical sensors
© 2012 www.DissertationTopic.Net Mobile
|