In recent years , the world-wide multiple chain failure resulting grid blackouts , This is a wake - up call for the safe and stable operation of the power system . To ensure the security of the power system , stable , reliable operation is the inevitable requirement of social development , the trend of large-scale interconnected power system and electricity market of the research chain failure prevention and control strategies has important theoretical and practical significance . In this paper, the improved N-1 single- cast safety algorithm based on the network topology , the algorithm considering the whole system in the case of the network topology changes and PMU device failure completely observability , through the initial configuration , and redundant configuration and further optimize the allocation of three steps , to achieve the optimal allocation of the PMU measuring device . Second on the definition and classification of the sensitivity analysis . DC power flow model based on the derived node injected power line active power static active sensitivity mathematical model . Verified by simulation , data comparison , the results showed that the sensitivity of the accuracy of the mathematical model of the static active . Finally, a the chain fault prevention and control strategies based on sensitivity analysis , and the control strategy can be divided into three steps . Step 1 : Using DC power flow model based on the PMU improved prevention and control strategies the desired fault before and after initial power flow data , the formation of the high-risk branch active power flow data set , looking to set out the most serious slip . Step 2 : Using the static the active sensitivity mathematical model to calculate the static meritorious sensitivity of each generator and load the overload slip . Static the meritorious sensitivity data of the generator and load control point grading . Third step: select the control points for the initial control amount calculating the initial control amount , then by the related constraints to be optimized to obtain the optimum control amount , this optimum control amount to control the system to achieve the elimination of branch circuit overload purposes. The algorithm can deal with a single line too contained more lines overload both the example simulation analysis , the results verify the effectiveness of the proposed control strategy to achieve the prevention branch passing contained triggered cascading failures of purpose , and thus prevent the grid large area blackout occurred .

Related Dissertations

  1. Study of Distributed Power System Phasor Measurement Uit,TM935
  2. I2C bus , JTAG bus power management class chip test,TN407
  3. The Study of Under-Frequency Under-Voltage Load Shedding and Their Coordinated Approach,TM712
  4. PMU Application Prospect in the Distribution and the Optimized Allocation of Research,TM769
  5. Research on A New Method of Synchronized Phasor Measurement and Unit Design,TM76
  6. The Innovation Graph Parameter Estimation in the Observability System of PMU Measurement,TM76
  7. Technology and Tool Desgin of Performance Tuning for Parallel Programing on Multi-core Platform,TP332
  8. Research on the Internal Control of the Operational Risk of Commercial Banks in China,F832.2
  9. Research on Grid Intelligent Alarming,TM76
  10. Guizhou of 220KV Power Grid PMU device the most advantages configuration design,TM76
  11. PSS Parameters and PMU Placement Optimization Based on Taguchi Method,TM76
  12. Research on Fast Topology Identification Based on Graph Theory,TM711
  13. WAMS / PMU data processing and its application in load modeling,TM714
  14. Research on Optimal Configuring of Power Quality Monitors in Distribution Network,TM764
  15. High-power analog integrated circuits DC parametric test and Implementation,TN431.1
  16. Estimate Static Voltage Stability of Wind Power System Based on Phase Measurement Unit,TM712
  17. PMU -based analysis of network topology information fast,TM711
  18. Parameter Identification of Synchronous Machine Based on WAMS,TM341
  19. A New Approach to Coherency Identification of Generator Clusters and Transient Stability Prediction Based on Phasor Measurement Unit,TM712
  20. Study on the Power System State Estimation Algorithm Considering PMU,TM744

CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Power system scheduling, management, communication > The operation of the power system
© 2012 www.DissertationTopic.Net  Mobile