Dissertation > Excellent graduate degree dissertation topics show
Experimental Research on Overvoltage in Switching off Shunt Reactor and Capacitor of Vacuum Circuit Breaker
Author: FuWenGuang
Tutor: ChangXianRong
School: North China Electric Power University
Course: Electrical Engineering
Keywords: Vacuum breaker Overvoltage Closure Rekindle
CLC: TM866
Type: Master's thesis
Year: 2011
Downloads: 99
Quote: 0
Read: Download Dissertation
Abstract
|
Operating over-voltage vacuum circuit breakers at home and abroad , Research overview and analysis from the theoretical aspects of the mechanism of the vacuum circuit breaker over-voltage power reactors and capacitors , the vacuum breaker breaking capacity inductive load , due to the closure phenomenon sometimes produce higher amplitude and steepness of the overvoltage and reignition of harm to the equipment insulation breaking 35kV reactors and capacitor test site . Taken to replace the circuit breaker vacuum bubbles , using ordinary metal oxide surge arresters , band gap and without gap the modular metal oxide surge arresters, RC absorber such the voltage suppression measures were operating tests measured voltage data and analysis the effectiveness of several protection measures taken , drawn open power reactor over voltage protection program that is installed on the 35kV busbar set RC in situ in the reactor , the installation of a group of RC in order to achieve a better realization protection of the circuit breaker and white , installed in the switch load side group HY5WZ-51/150 * 134 three-phase combined metal oxide surge arresters without gaps . Vacuum breaker breaking of the capacitor voltage to take protective Feasibility field validation tests showed off RC protection device off over the capacitor voltage can be effectively suppressed . Finally, the need to pay attention to the problem of the pros and cons of several protection device performance and use were discussed RC protection device relative superiority of [ the performance of other devices . The conclusions and analysis can be off the broken the 35kV system reactors and capacitor overvoltage protection program to provide a reference on over -voltage protection device design and selection , and at the same time can provide a reference . The overvoltage protection of power system stability and economic operation has important practical significance . Finally , the prospect of in-depth study of high-performance over-voltage protection device .
|
Related Dissertations
- Research on High Frequency Transient Overvoltage of Tightly-coupled Split Reactor Using in Parallel High-Voltage Circuit Breaker,TM864
- Fuzzy topological Some Issues,O189.11
- Clinic Study about Protraction of Mandibular Second Molars into First Molar Edentulous Site in Sliding Mechanics with Miniscrew Anchorage,R783.5
- Risk Factors of Shallow Anterior Chamber after Trabeculectomy in Primary Angle Closure Glaucoma,R779.6
- Research and Realization on New Type Intelligent Controller of Permanent Magnetic Actuator Vacuum Circuit Breaker,TM561.2
- Research on the Modeling of the Online Over-voltage Monitoring System and the Numerical Inversion Calculation Methods,TM866
- The Application Research on Round Extruosion Round Technology in the Middle of Hot Sealing Bag-Making Machine,TB486
- Study on the Synchronous Controller of Permanent Magnetic Actuator Used in Vacuum Circuit Breaker,TM561.2
- Development and performance study of controlled expansion plugging agent,TE28
- Leadership and ideology - on Laclau 's theory of ideology,B089
- The Research of the Function of Vacuum-assisted Closure in the Progress of the Chronic Wound Healing,R64
- A hybrid fuzzy clustering algorithm and its application,O159
- Study on the Adjustment Methods of Water Flooding Well Pattern of the Class Ⅱ Reservior in Polymer Injection Blocks,TE324
- Research on Permanent Magnet Linear Motor Operating Mechanism for Vacuum Circuit Breaker,TM359.4
- Research of the Influence of the Residual Charge on the VFTO in the GIS,TM86
- Finite Element Intensity Analysis of Heat Exchanger with Coupling of Closure Plate and Tube Plate,TQ051.5
- The Trituration of a Seawater Plunger Reciprocating Pump,TH322
- Study and Application of a Power Factor Correction Chip without Multiplier,TM46
- No. Ⅳ Tongqiao eyesight of primary angle-closure glaucoma optic nerve of different interventions under the protection of Efficacy,R276.7
- The Clinical Observation of the Nerve Growth Factor’s Neuroprotection for Glaucoma,R775
CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage measurement and test
© 2012 www.DissertationTopic.Net Mobile
|