Dissertation > Excellent graduate degree dissertation topics show
The Influence of Multi-phase Medium to the Capacitance Detection of Micro-gyroscope with Liquid Levitated Rotor
Author: ZuoWen
Tutor: LiuXiaoWei
School: Harbin Institute of Technology
Course: Microelectronics and Solid State Electronics
Keywords: Levitated Rotor Mirco-gyroscope Weak Capacitance Detection Two-phase Flow Void-fraction
CLC: TM934.23
Type: Master's thesis
Year: 2013
Downloads: 4
Quote: 0
Read: Download Dissertation
Abstract
|
With the development and improvement of microelectronics and MEMStechnology, MEMS transducers have a qualitative improvement in volume, mass,power, precision and many other aspects of performance. The improvement ofintegration has made inertial sensors widely used in military and civilian,especially the silicon accelerometer and gyroscope has been the focus of theresearchers at home and abroad.This paper presented a detection scheme of weak differential capacitive signalfor liquid levitated rotor micro-gyroscope and analyzed the problem of the two-phase or multi-phase flow existing there and the impact of them to the capacitancedetection. The paper mainly includes two aspects, one is the design of weakdifferential capacitance detection circuit, the other one is to analyze the two-phaseflow problem existing in the levitated rotor micro-gyroscope system.For weak capacitance detection circuit, this paper first analysed severalprinciple of weak signal detection, propose the appropriate differential capacitancedetection scheme which is based on the principle of phase-sensitive demodulation,and completed the Hspice simulation of every part of the circuit:the charge circuitamplifier, AC locked amplifier, phase sensitive demoudulation circuit and filtercircuit.The equivalent input noise of simulation is9.8641nV/Hz1/2at100kHz.These proved the correctness of the circuit and then completed the PCB design ofdetection circuit, the equivalent input noise is125nV/Hz1/2and it can achieve theresolution about5107.For the analysis of two-phase flow problem, this paper built a parallel platecapacitor, and put forward a theoretical model of two-phase flow in parallel platecapacitor, and the simulation and experimental results were consistent with thetheoretical model, found that the capacitance and two-phase flow void fractionshowed a linear relationship; also through the experimental test of four kinds ofliquid medium, analyzed the influence of velocity, temperature, excitationfrequency to single-phase liquid medium, all of these helpd to analyze errors ofdetection and guide the choose of liquid media for the levitated rotor gyroscope.
|
Related Dissertations
- Study of the High Temperature Gas-Liquid Two Phase Flow Rate Proportional Conrtol Valve,V233.2
- Study of Effect of High Temperature Seperator on Hydrodynamices in CFB Boiler Furance,TK229.66
- Study on Gas-Solid Two-Phase Flow in Spouted Beds,TK173
- Flow Behavior Description of Two-Phase Flow Based on Image Processing Techniques,TP391.41
- Study on Bubble Behaviors in Anode Channel of a Passive Direct Methanol Fuel Cell,TM911.4
- The Design and Research of the Superheated Steam Saturator,TK17
- An Investigation of the Frictional Pressure Drop of Air-Water Two-Phase Flow in Vertical Helicoidal Coiled Tube,TK172
- Optimal Chioce of the Technical Parameters of the Bag-type Dust Collector System in Mu Gua-jie Coal Preparation Plant,X701.2
- Numerical Simulation of Fluid Field and Temperature Field Within the Breaking Rotary Dryer,TK173
- Study on Regularity of Dust Transport Based Upon Induced Wind,X513
- Numerical Simulation of Fluid Field and Temperature Field Within the Rotary Vane Dryer,TK173
- Study on Modeling and Optimal Design of Capacitively Coupled Electrical Resistance Tomography System,TP212
- Electrothermal chemical gun interior ballistic meshless method numerical simulation,TJ012.1
- Study on Phase Fraction Measurement of Two-phase Flow with High Water Cut Based on Coaxial Conductance Sensor,TE81
- Cleaning phase flow method using complexation - ultrafiltration membrane module of pollution,X703
- CFD Simulation on Two-phase Flow Field of Combined Directed Floating Valve Trays,TQ053.5
- Study on the Exhaust Cooling Absorption System of the Closed Cycle Diesel Engine,U664.121
- Thermal Characteristics Research on High Speed Motorized Spindle Based on the Finite Volume Method,TH133.2
- Coal dust movement rule and Critical Control Technology,X701.2
- High-speed imaging system based on small pipe gas-liquid flow parameter measurement method,O359.1
- Numerical Simulation and Experimental Study on the Fluidization and Abrasion in a CFB Boiler,TK229.6
CLC: > Industrial Technology > Electrotechnical > Electrical measurement techniques and instruments > Lumped parameter,the distribution parameter measurement and instrumentation > Capacitance measurements and instruments > Capacitance Measuring