Study on Dose Verification of IMRT with Film Dosimetry

Author: HanJun
Tutor: WuChaoXia;LiQin
School: Tsinghua University
Course: Biomedical Engineering
Keywords: intensity modulated radiation therapy(IMRT) quality assurance(QA) quality control(QC) γindex NAT index
CLC: R815
Type: Master's thesis
Year: 2010
Downloads: 6
Quote: 0
Read: Download Dissertation

Abstract


Due to the application of intensity modulated radiation therapy (IMRT) to clinic, dose verifications become important to ensure dose distribution gradient of IMRT to be delivered to patients. Radiographic films are widely used for relative dosimetry in IMRT. Film dosimetry shows a high spatial resolution image and high cost- performance ratio. Film dosimetry offers a convenient and quick method to obtain a two-dimensional dose distribution and store for a long term.Radiographic films of silver halide emulsions will be affected by many factors. In the procedure a little error will reduce the accuracy and even causes a large failure with dose evaluation. The object of this thesis is to explore the different effects in film dosimetry procedure and to set up an IMRT dose verification system on base of film dosimetry.In this thesis, method to definite and to calculate the optical density (OD) value by film dosimetry was explored. Three methods of calibration film of dose&OD responding curve were also explored. The optimization method was confirmed. In film flushing process, the different temperature setting to affect OD, difference between different batches of film, the effect of different batch’s developer and fixer solution, the change of dosage and responding curve of the same batch film under the same batch solution were analyzed. As a result, the best process temperature 29-31℃was determined . Different batches of film couldn’t be confounded. A new calibration film must be obtained when the film dosimetry to evaluate dose distribution was used. During analysis of influence of the scanning condition, the effect of light uniform, the stabilize work time and the noise of different scanning resolution were discussed. A 10-miniters -delay for stabilize work and the best setting resolution/depth lever were 72dpi/16bit for scanning films were determined .In order to analyze the clinical significance of this study, the passing ratio ofγindex and the NAT index were compared before and after the quality control .The result of dose evaluation showed our research had a strong clinical significance.In addition, the advantages and limits between the film dosimetry and a two-dimensional ion chambers matrix in IMRT dose verification were compared. Because the ion chambers matrix has a lot of interval for 0.76mm of small size ion chambers, it don’t suit for some IMRT cases, And the film dosimetry has an excellent resolution for best use in IMRT dose verification. So we can reference the film dosimetry characteristics better to use of the two-dimension ion chambers matrix.

Related Dissertations

  1. Quality Control and Quantitative Analysis in Positron Emission Tomography Imaging,R817
  2. Three-Dimensional Conformal and Intensity-Modulated Whole Pelvic Radiotherapy in Posthysterectomy Cervical Carcinoma,R737.33
  3. Studies on the Chemical Figerprinting of Qingkailing Injection,R286
  4. Accounting & Control of the Medical Service Quality Based on Patient Satisfaction,R197.3
  5. The Study on Radiobiological Effects of Prolonged Fraction Delivery Time in IMRT Model,R730.5
  6. Canine Spinal Conformal Intensity Modulated Radiation Therapy after the Dynamic Changes of MBP and Its Significance,R651.2
  7. Study of Construction Quality Management in "WUHAN YINGWU Flyover" Project,U445.1
  8. Dosimetric Characteristics of Photon Beam in the Medium Interface Region,R815
  9. A Feasibility Study of IMRT Dosimetric Verification Using Radiochromic Film,R815
  10. Study on the Image Registeration Integrated with the LQ Model,R815
  11. An Experimental Study on Material Properties of the Novel Embolic Microspheres,R815
  12. Trituration of the Non-adhesive Liquid CoHEMA Embolic Mixture,R815
  13. Dose Verification of Intensity Modulated Radiation Therapy,R815
  14. Modeling on Automatic Selecting Beam Arcs in X-Knife Radiation Therapy Planning System,R815
  15. Uterine artery embolization for uterine effects and Anisodus alkaline albumin microspheres experimental study of uterine artery embolization,R815
  16. Study on the X-ray Developable Microspheres,R815
  17. Silk segment partial splenic embolization Applied Research,R815
  18. Experimental study of bFGF artery perfused rabbit hind leg ischemia model,R815
  19. The basic and clinic study of AVM embolic agent-NBCA mixed liquid ration,R815
  20. Experimental Study On Embolization Of Superior Mesenteric Artery Branches,R815

CLC: > Medicine, health > Of Medical > Radiation Medicine > Radiotherapy
© 2012 www.DissertationTopic.Net  Mobile