Dissertation > Excellent graduate degree dissertation topics show
Research on Equivalent Method for Large-scale Power System
Author: YangJinGang
Tutor: FangDaZhong
School: Tianjin University
Course: Proceedings of the
Keywords: Inter-connected Power System Coherent Equivalence Generator Unit Aggregation Sparse Matrix
CLC: TM744
Type: Master's thesis
Year: 2010
Downloads: 149
Quote: 0
Read: Download Dissertation
Abstract
|
With the trend of inter-connection and deregulation among the power systems, the relationship among the different areas is intensified. When fault occurs in one area, it is likely to lead to other areas’instability. So, the impact from the external power systems has to be taken into consideration when conducting security assessment on its own. This results in two aspects, one is improving the precision and the accuracy of the analysis, the other is slowing the calculating speed, which is unbearable in the recent aspiration of real-time security analysis.Network reduction is the process of reducing the dimension of the power system, while keep the researched area unchanged and preserve the external networks’influence on the researched area. The large-scale power system equivalence is very important for the steady state power flow analysis, transient stability analysis, and the real-time security analysis.Coherent equivalent algorithm is a classical equivalent method in the large-scale power system off-line transient stability analysis. It is typically done in the next three steps: identification of the groups of coherent generators, reduction of the external network, and aggregation of the coherent generators. In the first step, coherent generators are identified using linear simulation or manual identification; in the second step, the network reduction is based on the constant megavolt ampere (MVA) technology, in this process we often use Ward equivalent method or REI equivalent method to reduce the nodes in the external network; in the last step, we keep the equivalent generator’s transfer function identical with the set function of the single generator’s transfer function in the frequency domain.The effectiveness of the dynamic equivalent method is based on the model of the equivalent generators and its’parameters. For generators we try to select the model with most possible high order, such as transient model and sub-transient model. For exciter model, in the practical application, we only need to classify the major aspect (such as E- model and F- model in the BPA software), and the result is mostly acceptable. For primer mover and its controller, they can be neglected because the equivalent generator’s moment of inertia is always great.In the process of the network reduction and the generators’transient simulation, we have to solve great amount of matrix calculation. Besides, the dimension of the matrix of the power system is always high, it is important to use the sparse matrix technique. When solving the sparse matrix, we conduct LU decomposition to form L, D, U matrix. Finally we can use the L, D, U matrix to solve the linear function and the inverse matrix, even the sensitivity calculation.The simulation results on the inter-connected power system (the data given by the Tianjin power grid in the winter, 2005) validate the efficiency of the coherent equivalence.
|
Related Dissertations
- Interaction between the HVDC and FACTS controllers,TM761
- Optimal Reserve Modelling in Regional Interconnected Power System,TM743
- Algorithm Study of Steady-State Controlpower Flow Based on Tie-Line Power Constraints on Medimu Term and Long-Term Voltage Stability,TM712
- To tuning Studies based dynamic identification of power system stabilizer parameters,TM712
- Research on Oranically-Structured of Expanding Large Scale Systems Based on Parameter Optimization,TP273
- Research on Technology Platform for Fast Forming Simulation of Auto Body Part and Key Algorithms,TP311.52
- Research on the EMTP-TSP Hybrid Simulation of Complex AC/DC Interconnected Power System and the Relative Problems,TM743
- Matrix Valued Rational Approximation and Applications in Control Theory,O151.2
- Simulation and Application of Three-Phase Sparse Matrix Converter,TM46
- Support vector machine learning algorithm sequential minimal optimization,O242.23
- THE GRADIENT PROJECTION METHOD FOR LARGE SPARSE PROBLEM,O224
- Sparse Matrix Factorization Based on FPGA,TN791
- The Research of the Accuracy Reflected by CPS Indicator in the FM of Regional Control,TM732
- Optimization and Realization for Sparse Matrix-Vector Multiplication on FPGA,TP332
- Study of Parallel Computing System for Model Predictive Control,TP273
- Fast Analysis for Complicated Electromagnetic Problems and the Software Implementation,TP311.52
- The Decentralized Coordinated Control for AC/DC Hybrid Interconnected Power Systems,TM762
- Solution of Large Sparse Matrix in Network Research and Influence of Traffic Model on Worm Tracing,TP393.08
- Some Problems of Matrix Computing and Applications in Image Recognition,TP391.41
- Research on Some Key Problems of On-Line Pre-Decision System for Large Scale Interconnected Power System,TM76
CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Power system simulation and calculation > The calculation of the power system
© 2012 www.DissertationTopic.Net Mobile
|