Dissertation > Excellent graduate degree dissertation topics show
Three-level Static Synchronous Compensator Integrated with Distribution Transformer
Author: ZhangZuo
Tutor: WenMingHao
School: Huazhong University of Science and Technology
Course: Proceedings of the
Keywords: static synchronous compensator distribution transformer tap-inserted Controller control algorithm Modulation Mode dynamic simulation test
CLC: TM761.12
Type: Master's thesis
Year: 2013
Downloads: 8
Quote: 0
Read: Download Dissertation
Abstract
|
With the great development of the power electronics and the digital control technology,the theory, method and achieve means of the static reactive power compensation technologyhave made great progress. Besides, the application of the Static Synchronous Compensator(STATCOM) is more and more wide. It has played an important part in the aspects ofdynamic reactive power compensation, harmonics restraint and improving the systemstability in power system. For the present, the application of the STATCOM in thedistribution network is mature. However, there are many questions in the aspects of thetopology of the main circuit, the join up method and the control technology in STATCOMthat are worth studying.The three-level DT-STATCOM joined up from the distributiontransformer tap and its control panel proposed in this paper has got some achievement inthe aspects of lowering the access voltage of the STATCOM, improving the compensationratio and increasing the expansibility of the complicate control function.The basic theory of the reactive power compensation of DT-STATCOM is studied first.According to the distribution transformer of Yyn type and Dyn type, integration structuresof single-tap and multi-tap are designed respectively. he problem of the how to choose thevoltage of the transformer tap that connecting the STATCOM to make a more satisfactoryreactive power compensation ability without the overload in the high-voltage winding isstudied.On the basis of the analysis of the main circuit of DT-STATCOM and its workingprinciple, the efficient controller based on DSP and FPGA is designed. The total designscheme is introduced. The design principle, function configuration and the design schemeof the hardware and software are explained systematically.The reactive current detectionalgorithm, common control strategy and SPWM modulation method in DT-STATCOM areanalyzed in this paper. On that basis, the program achievement and software design of thecontrol strategy and modulation method that adopted by the scheme is illustrated accordingto the actual development of the controller of D-STATCOM.The dynamic simulation test platform of DT-STATCOM system is designed and developed. The dynamic simulation test scheme of tap-inserted DT-STATCOM system isdesigned. The tap-inserted compensation ability of the distribution transformer-STATCOMintegrated compensation system is tested by the dynamic simulation. The results verifiedthat DT-STATCOM has a good performance in reactive power compensation.
|
Related Dissertations
- Study on Theory and Technique of STATCOM Integrated with Distribution Transformer,TM761
- Study on the Control System and Experiments on Voltage Compensation Type Active Superconducting Fault Current Limiter,TM56
- Distribution Transformer Monitoring System Based on ZigBee Communications Network Platform,TM76
- Research on Technology of Data Acquisition in On-load Automatic Voltage Regulating Distribution Transformer,TM421
- Design of Distribution Transformer Monitoring Terminal (TTU) Based on ARM,TM764
- Research on Intelligent Control Strategy of D-STATCOM,TM76
- Study on Harmonic Additional Loss Monitoring Method and Experiment of Distribution Transformer,TM421
- Research on the On-line Detection Method for the Loss and Capacity of Distribution Transformer,TM421
- Design and implementation of GPRS distribution transformer monitoring management system based on,TM76
- Study on Single and Three-Phase Power Combined Distribution Technology in Urban and Rural Grid,TM72
- The Design of an Intelligent Transformer Terminal Unit,TM764
- Research on the Integrated Compensation of Reactive and Negative Currents for Unbalanced Load,TM714.3
- Power load management master system based on GPRS technology,TM73
- Research of the Key Technologies for the Distribution Automation System and Development of Transformer Terminal Unit,TM76
- The Design and Implement of the Power Load and Distribution Monitoring Terminal Based on ARM,TM933.4
- Application of 3G network distribution transformer monitoring system design and development,TN929.5
- The Design of GPRS-based Monitoring System of Distribution Transformer,TN929.5
- Research on Main Circuit of STATCOM Based on IGCT,TM761
- Multiwavelength Erbium-doped Fiber Laser Based on Phase Modulation and Polarization Hole Burning,TN248
- Distribution Transformer Running State Remote Monitoring System Disquisition,TM421
- The Software System Design of the Remote Power Distribution Transformer Monitoring Terminal, Based on μC/OS-II,TP311.52
CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Power system automation > Automatically adjusts > Automatic adjustment of voltage and reactive power > Test and simulation of automatic adjustment of voltage and reactive power