The Algorithms Research of Hypoperfusion for Pulse Oximeter
Author: AiZhiGuang
Tutor: ZhangZhi
School: Huazhong University of Science and Technology
Course: Biomedical Engineering
Keywords: Oxygen Saturation Hypoperfusion Autocorrelation Modeling FFT
CLC: R318.0
Type: Master's thesis
Year: 2012
Downloads: 12
Quote: 0
Read: Download Dissertation
Abstract
|
The algorithm of hypoperfusion for pulse oximeter is discussed in this thesis. Oxygensaturation is an important parameter of respiratory system and reflects the blood oxygencontent.Pulse oximeter is a usefull clinical mean to monitor SpO2、perfusion index(PI) andpulserate(PR)for its noninvasive、continuous and real-time. When the PI of users isextremely low,the pulsewaves detected will be so weak that useful signal is almost drawnby noise.It’s difficult to calculate the parameters.We designed a pulse oximeter based on STM32and PC.And then presented two newSpO2algorithms for hypoperfusion.The first is based on FFT and autocorrelation. Usingautocorrelation inhibit the noise and obtain the fundamental frequency of the originalsignal through the autocorrelation signal.According to the amplitude frequencycharacteristics of pulsewave, take the fundamental and second harmonic, three harmoniccomponent of original signal to rebuild signals which used to calculate the parameters.Thesecond is autocorrelation modeling method.According to the analytical relationshipbetween autocorrelation signal and original signal,directly calculate the parametersthrough the high SNR autocorrelation signal.We verified the feasibility of the above two algorithms through theory and simulationresults.Also we tested the accuracy and stability of above two algorithms in the conditionof low perfusion. The experimental results show that the two algorithms could calculateSpO2、PI、PR exactly on the condition that the perfusion is above0.2%.At last the secondalgrithom was integrated into our prototype system that improved the accuracy ofparameter calculation greatly to the pulse oximeter.
|
Related Dissertations
- Beer bottles online testing related technology research,TS262.5
- Design of Radio Interface Based on FPGA,TN791
- Research on the Analysis of Power System Harmonics,TM711
- Design and Realization of Signal Distortion Measurement System Based on Virtual Instruments,TP274
- Animals developed pulse oximetry components,S854.9
- Research on Technology and Application of Hand-held Low-frequency Vibration Signals Acquisition System,TP274.2
- DSP and FPGA System Based on Harmonic Analysis,TM711
- The Design of HF ALE Signal Detection Devices,TN911.23
- Research on Image Matching Based Target Detection Technology and Algorithm Design,TP391.41
- An Improved Method for Short-term Load Forecasting Based on FFT and Chaos,TM715
- Radial Shearing Interferometry Test Technology,TH744.3
- Millimeter wave detector signal analysis and processor design,TN911.6
- MSP430-based human signal detection and alarm system,TN911.23
- Research of Key Signal Processing Algorithms in Modern Spectral Analyzer and Its FPGA Implementation,TN791
- Development of Intelligent Vortex Flowmeter Based on HART Field Bus,TH814
- Research on the Testing of Analog-to-Digital Conventer,TN792
- Study and Design of Online Insulation Monitoring System for Hv Capacitive Equipment,TM934.3
- Study on the Analysis Methods of Harmonics in Power System,TM711
- Research of Adaptive Array Signal Processing Technology Based on OFDM Systems,TN911.7
- Design of Protective Relay System Based on Arm+μc/os-ⅱ,TM774
- Research and Design on the Harmonic Detector of Power System Based on ARM,TM935.2
CLC: > Medicine, health > Basic Medical > Medical science in general > Biomedical Engineering > General issues
© 2012 www.DissertationTopic.Net Mobile
|