Dissertation > Excellent graduate degree dissertation topics show

The Effective Factors on Measuring of BH3103B X-γ Dose Rate Meter and Evaluate Its Measurement Uncertainty

Author: WangYiXing
Tutor: Tu
School: Suzhou University
Course: Clinical
Keywords: uncertainty dose rate meters temperature voltage
CLC: R318.6
Type: Master's thesis
Year: 2013
Downloads: 8
Quote: 0
Read: Download Dissertation

Abstract


Objective:To explore the effective factors on measuring of BH3103B X-y dose rate meter and evaluate its measurement uncertainty.Methods:Choose a ambient temperature stable basement to test the influence of environmental temperature; Choose a open roof, with large temperature difference and few people, then use a stabilized voltage power to supply the instrument, to test the influence of battery voltage. Then use the experimental data to estimate the measurement uncertainty of BH3103B X-y dose rate meter. At last, use some examples to test the result.Results:1. At9.0V,BH3103B X-y dose rate instrument’s pointing error is (-1.5%~+3.1%).2. In the range of10to40℃,the counting error caused by environmental temperature is (-3.4%~+37.9%).3. In the range of8.0V-9.2V, the counting error caused by battery voltage is (-13.2%~+0.9%). 4. BH3103B X-y dose rate instrument’s expanded uncertainty is36.6%,(k=2).Conclusions:1. The BH3103B X-y dose rate instrument produced by Beijing Nuclear Instrument Factory is significantly affected by measurement conditions such as environmental temperature, battery voltage.2. Voltage test show that BH3103B X-y dose rate instrument with ordinary batteries can’t run continuously8hours.3. In the process of actual measurement, the influence of the temperature must be corrected from the data.4. BH3103B X-y dose rate instrument does not meet the provisions of Norm for the measurement of environmental terrestrial gamma-radiation dose rate (GB/T14583-93), but the measurement data conform to the scope of its expanded uncertainty.

Related Dissertations

  1. Preparation and Electrocaloric Effect of BaxSr1-xTiO3 Ferroelectric Thin Films,TB383.2
  2. Measurement of the Surface Impedance of the High Temperature Superconducting Thin Films with Coplanar Transmission Line,O484.5
  3. Study on Contact Fatigue Life Based on Grease Variation with Temperature,TH117.22
  4. Research on Temperature Measurement Technique Based on CCD Image Sensor,TH811
  5. Design and Application of Scope Anti-Shake System,TH743
  6. Development of Explosion Flame Temperature Measurement System Based on Multi-Spectral Thermometry,TH811
  7. Temperature Drift Modeling and Compensation of Fiber-Optic Gyroscopes,V241.5
  8. Analysis and Study of Abutment Stability in Concrete High Arch Dam by Three-Dimensional Nonlinear Finite Element Method,TV642.4
  9. Research on Nozzle Plume Temperature Distribution Measurement System,V434
  10. Power System Dynamic Voltage Stability Simulation Study Based on Precise Integration Method,TM712
  11. Numerical Analysis of Flow Process in a Molten Carbonate Fuel Cell,TM911.4
  12. Experimental Research on Concretion Characteristics of High Temperature Syngas in Integrated Gasification Combined Cycle System,TM611.3
  13. The Basic Research of Axial Flux Inductor Type High Temperature Superconducting Motor,TM37
  14. The Development of Electric Control System for Product Line of Cross-Linked Cable,TP273.5
  15. Research on Temperature Control System for High-Performance Oven-Control Crystal Oscillator (OCXO),TN752
  16. Fly Ash study of low temperature ceramic foam,TU52
  17. Photosynthetic Apparatus Response to Heat Stress and the Mechanisms in Two Different Cotton with Various Leaf Colours,Q945.11
  18. Cultivation and Effects of Environmental Factors on Carrying WSSV Virus of Litopenaeus Vannamei,S945
  19. Parent Culture and Early Individual Development of Perinereis Aibuhitensis under the Cultivation Condition with Gracilaria Tenuistipitata,S968.9
  20. Effects of Light, Temperature and Nitrogen on the Growth of Three Kinds of Aquatic Plants,Q945
  21. Research on the Effect of Electrodes and Electrolyte on H2O2 Open Circuit Potential,TM911.4

CLC: > Medicine, health > Basic Medical > Medical science in general > Biomedical Engineering > Apparatus, equipment