Dissertation > Excellent graduate degree dissertation topics show

The Model and Internal Fixator Design of the Schatzker Ⅵ Tibial Plateau Fractures with Posteromedial Condyle Spliting and Its Biomechanical Comparision Study

Author: DengBing
Tutor: ZhuYong
School: Central South University
Course: Surgery
Keywords: Tibial plateau Fracture Inner condyle Internal fixation Biomechanics
CLC: R687.3
Type: Master's thesis
Year: 2010
Downloads: 81
Quote: 0
Read: Download Dissertation

Abstract


The purpose design partners within the posterior condylar splitting to Schatzker Ⅵ tibial plateau fracture model and new internal fixation devices, and the biomechanical comparative study guide clinical application. Method 1. 8 adult cadaver knees were Schatzker Ⅵ be made the posterior condylar within accompanied splitting fracture model. 2 the distal humerus Y Plates, pre-bent to fit the proximal tibia medial condyle shape, within the flank and rear flank each of three nail holes. Three different internal fixation methods were used according to the sequential order: group A: outside of LISS plate fixation group; group B: LISS osteosynthesis plate of the outside of the rear side of the Y-shaped plate fixation group; C Group: lateral, LISS The inside of the bone plate reconstruction plate fixation group. Displacements and anti-load performance testing of the biomechanics of different fixation group, respectively. Results. 1000N load within the front side of the displacement of the fracture fragments, B, C group of anti-load compression mechanical properties superior to Group A, the statistics show that the difference was statistically significant between group A, B, A, C group of The significant difference between the B and C groups showed no significant difference. 1000N load within the rear side of the displacement of the fracture fragments, B group anti-load compression displacement mechanical properties superior to group C, the C group was better than in group A, the statistics show that A, there was significant difference between group B, B, C group difference was statistically significant between the A, C group difference was statistically significant. Within the front side of the fracture fragments the failure load, B, C group biomechanical properties superior to Group A, the statistics show that the difference was statistically significant between group A, B, A, C between group difference was statistically significant , B, C groups showed no significant difference between 4. Including posterior fracture fragment the failure load and biomechanical properties of the group B is better than C group better than group A, group C, group A worst statistical significant difference between group A, B, B, C group difference was statistically significant between the A, C group difference was statistically significant. Conclusion 1. Was first established partners within the posterior condylar splitting to Schatzker Ⅵ tibial plateau fracture model. 2. Designed a new kind of applies to partners within the posterior condylar splitting Schatzker Ⅵ tibial plateau fractures within the rear side of the Y-shaped bone plate. Accompanied within the condyle after splitting Schatzker Ⅵ tibial plateau fractures using the LISS Plates combination of their own design within the rear side of the Y-shaped bone plate support with good biomechanical properties. 4 Schatzker Ⅵ tibial plateau fractures even with the outside of LISS Plates still need medial support.

Related Dissertations

  1. Clinical Study of the Extremely Low-frequency Pulsed Electromagnetic Fields on Accelerating Fracture Healing,R683
  2. The Establishment and Preliminary Application of the Three-dimensional Finite Element Model of Ankle Joint,R687.3
  3. Clinical and Radiologic Study of Percutaneous Pillar for Vertebral Compression Fracture,R687.3
  4. Study on the Characteristic Luling Coal Mine 10th Coal Seam Overlying Strata and Desruction during the Process of Stoping,TD327.2
  5. The Application of Stoppa Approach in Anterior Pelvic Ring and Acetabular Fractures,R687.3
  6. Simulated lunar ambient temperature magnesium alloy microstructure and mechanical properties of,TG146.22
  7. Al-Si-Cu-Nd cast aluminum alloy microstructure and fatigue properties,TG136.1
  8. Hot extruded Al-Mg-Si-Er alloys cyclic deformation and fracture behavior,TG379
  9. GH4169G alloy creep behavior of the organizational structure and,TG146
  10. MW-class wind turbine hub ductile iron QT350-22LT high- cycle fatigue properties of,TG255
  11. Acoustic emission signals laser detection and analysis,TB52
  12. Construction and screening of S1 fracture intein sentinel marker for protein,Q51
  13. Cracks in asphalt pavement structure with finite element analysis,U416.217
  14. Study and Evaluate of Stability and Water Gushing of Surrounding Rockmass in Karst Area Tunnel in Leguang Freeway,U453.61
  15. Stability Analysis of the Wall Rock in Fault Fracture Zone of Luya Mountain Along the Xinbao Highway,U451.2
  16. Research on Durability Evaluation Method of Cement Concrete Pavement,U416.216
  17. Studies on MGF-Ct24E for Bone Fracture Healing and the Bioactive Materials,R318.08
  18. The Risk Factors Analysis and Prevention Research During the Perioperation with Hip Arthroplsaty in the Eldly Femoral Neck Fracture Patient,R687.4
  19. Study on the Numerical Simulation for the Propagation Process of 3D Built-In Fractureand of Rock,TU452
  20. Kinetic Analysis of Trans-Splicing of Novel Split-Inteins in Vitro,Q51
  21. Hopkinson rod test optimization and oxygen-free high conductivity and tensile fracture of constitutive,TG115.52

CLC: > Medicine, health > Surgery > Orthopaedic Surgery ( movement system diseases,orthopedic surgery ) > Orthopedic surgery and surgery > Bone surgery