The Analysis and Evaluation of Guangzhou Metro HVAC Cooling Tower Performance

Author: GuoYing
Tutor: LiuJinPing;XiaShaoDan
School: South China University of Technology
Course: Power Engineering
Keywords: Noise pollution thermal pollution thermal performance correlation analysis
CLC: TU831.8
Type: Master's thesis
Year: 2011
Downloads: 66
Quote: 0
Read: Download Dissertation

Abstract


Since the construction of Guangzhou Metro Line No. 1 June 28, 1999 officially opened since 2010, has been owned by 8 lines, with a total length of more than 200 kilometers of rail line network. In addition to line 2 Haizhu square station using the Pearl River water as cooling, the rest are cooling tower cooling. Mainly low-noise cross-flow cooling towers, sub-station cooling station to use more parallel operation of two cooling towers, concentrated cold station with multiple units operating in parallel. To meet the requirements of urban planning, combined with the specific circumstances of the station, Guangzhou Metro Line has been operating mainly in the cooling Tabu set the following form: 1, together with the construction of subway air pavilion; 2, sunken arrangement; 3, together with the construction of the property; 4, the ground layout. Layout due to different cooling tower on the surrounding environment caused by noise pollution, thermal pollution, and their thermal performance varies.The noise of a typical cooling tower, water temperature, cooling tower water temperature, the cooling tower inlet air temperature, relative humidity, inlet cooling tower, cooling tower outlet temperature, relative humidity, the wind cooling tower, cooling water flow, then water cooling tower plate temperature distribution, temperature and humidity, atmospheric pressure and other operating parameters for field testing, for a typical cooling tower noise control site to discuss the situation, and different noise reduction measures under the conditions of the cooling tower thermal performance analysis.Through the data analysis and evaluation, research noise pollution, thermal pollution and the correlation between the thermal performance, ways of improving the cooling tower cooling capacity, reduce noise pollution and thermal pollution of the method for optimization of cooling tower design and energy-saving operation to improve reference .

Related Dissertations

  1. Recovery Boiler Inspection energy efficiency research and testing technology,X793
  2. The Analysis of Taste in Cigarette Mainstream Smoke and Establishment of Forecasting Model,TS411
  3. Study on the Thermal Performance of Residential Walls in Intermittent Air Conditioning Run Mode,TU111.4
  4. Research on Rapid Corrosion Meter Based on Electrochemical Impedance Principle,TG174.3
  5. CNC lathe spindle thermal characterization,TG519.1
  6. Aluminum die-casting thermal module design research,TG249.2
  7. The Research of the Circumference Standard of the Female in Jiangsu and Zhejiang Areas Based on 3-D Measurement,TS941.17
  8. Study on Solidification Process of Super-huge Steel Ingot,TG244.3
  9. Study on the Wearing Performance of Pearl Fiber Knitted Fabric and Its Functions,TS18
  10. The Distribution Characteristics of Osmiophilic Granules in Tobacco Leaves at Different Altitudes and the Relationship with the Quality of Flue-cured Tobacco Leaves of Huili,S572
  11. Processing Technique on Fog Random Error and Its Application,V241.5
  12. Research on Corporate Governance Structure and Changes in Accounting Estimates,F275.2
  13. The Infection Research of Transactive Memory Systeams to Team Performance in Top Management Team,F272
  14. Study on Scale and Driving Forces of Construction Land of Tacheng,F224
  15. Research on the Relationships between Financial Competitiveness and Corporate Governance,F276.6;F224
  16. Research on Intelligent Fault Diagnosis of Rolling Bearing Based on Non-stationary Signal Processing,TH165.3
  17. Study on Highway Transportation in Shanxi Province and the Correlaive Analysis of Economic Development Level with It,F127;F224
  18. The Pricing Strategy of Multi-client Segmentations by Revenue Management in a Competitive Shipping Industrial-by Illustrating the Asia-Europe Service of Yangming Line,F224
  19. Influence of Humic Acid on the Oxidation of Phenols by Permanganate,O611.3
  20. Study on the Quantitative Area Risk Assessment Model of Chemical Industrial Park,F426.7
  21. Study on Modification and Fiber Formation of Poly(3-Hydroxybutyrate-Co-3-Hydroxyvalerate) (PHBV),TQ342

CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning > A variety of housing air-conditioning
© 2012 www.DissertationTopic.Net  Mobile