Design of the Reflective Near Infraded Moisture Measurement Instrument Based on the Method of Three Wave Bands and Six Beams
Author: LiHuaXing
Tutor: LiXinGuang
School: Northeastern University
Course: Detection Technology and Automation
Keywords: near infracted spectrum moisture measurement near infraded detector three wave bands and six beams
CLC: TN214
Type: Master's thesis
Year: 2009
Downloads: 20
Quote: 0
Read: Download Dissertation
Abstract
|
Reflective near infraded moisture measurement instrument is an important application of near infraded spectrum. When near infraded beam is irradiated to the tested material, the attenuation of the reflection of beam can reflect the moisture content. The measurement method based on three wave bands and six beams can elimate the measurement error caused by the change of the lamp and the tested material.Based on the research of near infraded measurement theory, optimized design method of three wave bands and six beams is proposed in the paper to complete the overall design of the instrument and improve the stablity. Then according to the low noise analysis and reasearch of the confidential component Pbs detector, method of low noise moisture signal measurement system is detailed designed and implemented through system hardware circuit optimized design. The precised sampling and processing of the moisture signal is implemented by designing software procedure using reasonable data processing method, which improves the precision of the instrument. PC monitoring software is designed to store and manage the moisture data.Hardware circuit system mainly include the high precision power system circuit, low noise moisure signal measurement circuit, high precision temperature control system circuit and central processing circuit.The design of software data processing method mainly include the sample ratio algorithm, sample integration and digital average filter algorithm, PID control algorithm and stable frequency interference filter algorithm.Through a lot of measurement experiments and performance tests after calibration, the designed reflective near infraded moisture measurement instrument is proved to have a good stability and repeatability. Calibration data fitting method is analyzed and compared to do the moisture content measurement experiment. The experiment result indicates that the measurement error of the instrument is small, which can satisfy the need of practical application.
|
Related Dissertations
- Based on low-energy rays oil moisture measurement instrument of fast,TE622.1
- The Development of High Performance Eletrolytic Trace Water Analyzer,TH83
- Numerical Research of Wafer Cone Meter on Its Expansibility Factor and Characteristics of Wet Gas Metering,TH814
- Research on the Infrared Moisture Testing Method by Fiber Sensor,TN215
- Research and Development of the Near Infrared Moisture Measurement Device,TH83
- Capacitive Sensor Based on Active Bridge Circuit and Its Measurment System,TP212.1
- Researches and Applications of Information Fusion Technology on the Embedding Internet Grain Moisture Measuring Instrument,TH79
- On-line Testing of the Moisture Content of Veneer Based on Microwave Technique System,S781.33
- The Infrared Moisture Device of Paper by Fiber Sensor,TN214
- The Method of Measuring the Moisture in the Coal,TH83
- Researches on the Technology of Grain Moisture Measurement Based on Data Merging,TH83
- Study on Measurement Technology of Micro-moisture in Cold Spray Gases for Attitude Control,V467
- The Research of Capacitive Water Content Measuring System Based on Complex Impedance Separation,TP274
- Study on Design of Instrument for Soil Humidity Measurement Based on Dual-Spectrums,TH83
- Study of Wet Gas Metering Technology Based on Slotted Orifice and Swirlmeter,TH814
- Wet Gas Measurement Based on an Inner and Outer Ring Capacitance Sensor,TP274
- Sheet of high precision and low quantitative infrared moisture meter developed in the paper production,TH83
- Research on Spectral Imaging Using of Infrared Imaging System,TN214
- Study on the Preparation and Properties of Polyaniline Modified Electrode for IR-electrochromic Device,TN214
- Image Stabilizing Research of the Infrared Thermal Imaging System,TN214
CLC: > Industrial Technology > Radio electronics, telecommunications technology > Photonics technology,laser technology > Infrared technology and equipment > Infrared optics
© 2012 www.DissertationTopic.Net Mobile
|