Determination of Radiation Sterilization Dose of Central Venous Catheter and Systematic Study of Radiation Adaptability

Author: HuangZuo
Tutor: LiuQingFang
School: Suzhou University
Course: Public Health
Keywords: irradiation sterilization blood compatibility central venous catheter blood coagulation function platelet function
CLC: R187
Type: Master's thesis
Year: 2011
Downloads: 14
Quote: 0
Read: Download Dissertation

Abstract


PurposeTo determine the radiation sterilization dose of the central venous catheter and systematically evaluate the radiation adaptability after the radiation sterilization of the central venous catheter so as to provide a basis for the safe application of the central venous catheter after radiation sterilization.MethodTo use ISO11137 Standard to determine the radiation sterilization dose of the central venous catheter and conduct the following tests of the sample after the radiation sterilization: tests of the blood coagulation function (TT、PT、APTT、Fg) , the platelet function (TXB2、Platelet Count) and the hemolysis rate; chromosome aberration test (Ames Test), micronucleus test, accelerated aging test, seal peeling test, agar attack and vacuum leakage test. To evaluate the radiation adaptability of the central venous catheter in terms of biocompatibility as well as the physical and chemical properties of packaging and products.ResultAs for the sample after radiation sterilization, no influence is shown in the blood coagulation function and the platelet function both before and after the whole blood of healthy people flows through the central venous catheter box, with the hemolysis rate being 1.38% (less than 5%), which is up to the medical appliance hemolysis test requirements. Ames Test shows that there is no evident difference in the number of revertant colonies existing in the central venous catheter leaching liquor and in the negative control group under both active and non-active conditions. The micronucleus test indicates that in the three different-dose groups of the leaching liquor of central venous catheter system, there is no increase is found in the occurrence frequency of the micronucleus and in the ratio of polychromatic erythrocytes to normoblast. Statistic analysis shows that between the individual treatment groups and the negative control group, no significant difference is found in the occurrence of micronuclei, no and genetic toxicity is found (no chromosomal aberration is caused), no allergy nor intracutaneous irritation is caused and no change is found in the material quality and performance of the packing material of product, and the blood compatibility proves to be desirable.ConclusionAfter the radiation sterilization with determined dose, the central venous catheter is of good radiation adaptability, and thus radiation sterilization, as a means of sterilization for medical appliances, is worth popularizing.

Related Dissertations

  1. Synthesis and Biocompatibility of different types of hydrophilic surface - modified polyurethane,R318.08
  2. The application of nanotechnology in the field of anti - coagulation of biological materials,R318.08
  3. Synthesis and properties of new functionalized graphene oxide drug carriers,TQ460.4
  4. Synthesis and Properties of the new anti-clotting material in modified ammonium phosphate zwitterion,R318.08
  5. Polypyrrole coating cardiovascular devices for artificial surface modification of titanium-based experimental study,R318.08
  6. Central venous catheter closed thoracic drainage in spontaneous pneumothorax in the clinical application,R561.4
  7. The Clinical Application of Peripherally Inserted Central Catheter in Neonate,R472
  8. Surface Modification of Polycarbonateurethane Film to Improve Its Hemocompatibility by Covalent Linkage of Heparin,R318.08
  9. Preparation and Property Study of Electrospun PLA/Curcumin Composite Membranes,TQ340.64
  10. Effection of Continuous Negative Pressure Suction Drainage Associate with Fine Catheter in the Treatment of Spontaneous Pneumothorax,R561.4
  11. The Research of the Relation of the Post-Stroke Depression and the Platelet’ Function,R743.3
  12. Clinical Study of Catheter-related Bloodstream Infections of Critical Ill Patients in Intensive Care Unit,R446.5
  13. Treatment of Arthralgia Activating Blood Circulation Compatibility of Law,R255.6
  14. The Regulation of Nao Xin Tong to the Anti-platelet Effect of Clopidogrel on the CYP2C19~*2 Gene Mutation in Volunteers with Qi Deficiency and Blood Stasis Constitution,R259
  15. Studies on Synthesis and Modification of Biomedical Polyurethanes,TQ311
  16. Clinic Study and Analysis of Central Venous Cathetens Related Infection,R472
  17. Study on the Antibacterial Effect and Safety of Silver-containing Zirconium Phosphate Antibacterial Agents of Nanometer Level and the Made-up Central Venous Catheter in Vitro and in Vivo,R401
  18. The Research on the Risk Factors of Central Venous Catheter Related Infection in Hospital,R472
  19. The Research of Small-caliber Polytetrafluoroethylene Artificial Vessel with Sulfonated Silk Fibroin Film by Low Temperature Plasma Treatment,R318.11
  20. Radio Frequency Thermothermai with the Single Cavity Center Ductus Venosus Temperature Measurement of the Feasibility Study,R730.59
  21. Heat and activating blood compatibility on the diabetic ApoE gene knock in addition to the mouse coronary atherosclerosis,R285.5

CLC: > Medicine, health > Preventive Medicine,Health > Epidemiology and Prevention of Disease > Disinfection