Abstract


Lock-in effect laser gyro accuracy is an important factor , to reduce the lock area, you need to use a variety of methods to improve the gyroscope integrated backscatter . Optical Jitter is a lens through backscatter modulation to achieve improved gyro lock-in method , optical jitter thesis theoretical studies and experimental verification, to a certain conclusion. First introduced to improve the lock- optical dithering principle . Right stick on the lens in the laser gyro PZT additional optical jitter voltage signal, the lens will be based on the frequency of the signal light shaking amplitude according to certain rules sliding jitter, jitter amplitude when the lenses meet the specific relationship, in theory, can make the gyro back to minimize scattering , so as to achieve the purpose of improving the lock-in . Followed by the establishment of the quadrilateral changes in the optical path of laser gyro model , using the model to obtain a phase change of backscatter sliding the lens quantitative relationship between the amplitude . According to the cavity mirror translation of the amplitude-frequency curve for different frequencies to improve shake optically backscattered signal reaches the ideal optimum voltage value of the sensitivity of the optical cavity mirror shift jitter. Build an experimental platform , the frequency with the same amplitude , the phase difference of π constant two-way sinusoidal voltage signal loading to stick on the top two lenses implemented on a piezoelectric ceramic sliding jitter. Loading optical gyro dither signal lock area after test results show that the optical signal is actually improved lock- shaking trend in the jitter voltage amplitude is not large when basically consistent with the theory . Finally, the mechanical jitter plus noise , mechanical noise and jitter without mechanical jitter without additional optical jitter noise but three cases were compared gyro stability experiments , obtained optical jitter can play a similar mechanical gyro dither adding noise to improve conclusions performance . Additional optical jitter , the laser gyro dynamic lock reduced further validate the conclusions.

Related Dissertations

  1. The Inductive Load Based Vehicle Body Network Control System,U463.6
  2. The Research of Digital Lock-In Technology,TN911.8
  3. Ultrasound of new technologies on hyperthyroidism cause heart and liver damage evaluation,R581.1
  4. Preliminary development of cancellous bone trabecular separation algorithm estimates and ultrasound diagnostic system,R580
  5. The Study on Anti Power-stealing System,TM73
  6. Denoising Research of Underwater Images Backscatter Based on the Theory of Wavelet,TP391.41
  7. Variable Structure Control with Sliding Mode for Automobile Anti-lock Braking Systems,U463.526
  8. Research on the Vibration Reduction of Dithered Laser Gyro Strapdown Attitude & Heading Measurement System,TN966
  9. The Develop of High Performance Microwave Frequency Synthesizer Based on DDS+PLL,TN74
  10. Study on New Lock-in Amplifier Technology about the Signal of Practical THz Spectrometer,TN722
  11. Research on Lock Capacity on the Minjiang River Downstream,U641.7
  12. Losses Signal Simulation of Laser Gyroscope Cavity,TN966
  13. Research and Implementation of Baseband Signal Processing Algorithm for GPS Software Receiver Based on FPGA,P228.4
  14. Study on the Structure Property of CuSn Alloy Contact Wire for 350Km/h,U264
  15. Research and Design of FPGA Delay Locked Loop Architecture,TN791
  16. Research and design of the reader access control system based on the UHF band,TP273.5
  17. A Study on Lock-up Rule and Slip Control of 4AT Torque Converter,U463.221
  18. Prestressed chamber structure on elastic foundation with foundation interaction,TV223
  19. A Non-invasive Detection of Pulse Oxygen Saturation Based on NIRS,TP274.52
  20. Design the Antenna for Passive UHF RFID Tag and Analysis the Characteristics of Antenna-in-Package,TN820

CLC: > Aviation, aerospace > Aviation > Aircraft instrumentation,avionics, flight control and navigation > Aircraft instrumentation,aerospace equipment > Gyro instrument
© 2012 www.DissertationTopic.Net  Mobile