The Research on Thermal Field Calculation of Tightly-coupled Dry-type Air-core Split Reactor
Author: DengQiu
Tutor: LiZhenBiao
School: Huazhong University of Science and Technology
Course: High Voltage and Insulation Technology
Keywords: Tightly-coupled Dry-type Air-core Reactor Finite Difference Method Finite Element Simulation Temperature Field
CLC: TM47
Type: Master's thesis
Year: 2011
Downloads: 66
Quote: 0
Read: Download Dissertation
Abstract
|
The tightly-coupled dry-type air-core split reactor is the key equipment in parallel circuit breaker system, and used for two-slip current sharing and current limiting. The maximum temperature rise in the encapsulation of tightly-coupled dry-type air-core split reactor is an important technical indicator to measure its thermal stability. The research on temperature distribution law of dry-type air-core split reactor under its working condition helps to optimize reactor design and improves the quality of the reactor, so as to improve the security and stability of the whole power system.In this thesis, the physical structure of tightly-coupled dry-type air-core split reactor as well as its current sharing and current limiting operation mechanism is introduced, the inductance of tightly-coupled dry-type air-core split reactor when working under current limiting and current distribution condition is calculated respectively, the relationship between constructual parameters of encapsulation and inductance of reactor under current limiting condition is analyzed, the effect of number change of turns on current distribution of the encapsulations is also analyzed, so as to guide and optimize the thermal field design of the tightly-coupled dry-type air-core split reactor.The steady thermal field of reactor when working under natural convection and forced convection are simulated using finite element simulation software, and calculated using finite difference method respectively. The results of the two approaches are consistently the same: the maximum steady temperature rise of column-type air-core reactor happens approximately 10% to its top; In the 1/3 part of the reactor to its bottom, the temperature will rise rapidly to the increasing of height, yet the gradient rate is gradually decreasing; In the 10% part of the reactor to its top, the temperature will drop rapidly to the increasing of height; In the part between, the temperature will rise slowly to the increasing of height.Besides, The transient thermal field of column-type air-core reactor when working under forced convection is simulated using finite element simulation software, and calculated using finite difference method respectively. The result shows that: the transient thermal field of column-type air-core reactor’s encapsulation is mainly decided by the heat generation rates of each encapsulation, yet has little correlation with the wind velocity in airway of the both sides; The transient thermal field distribution law in every encapsulation of the reactor are the same, that is, the transient temperature rise from the bottom to the top of the encapsulation are the same; The maximum transient temperature rise of column-type air-core reactor rises linearly with the increasing of hearing time.In the last, the flow field distribution of dry-type air-core reactor when working under forced convection with different structure of air ducts and rain shelters are calculated respectively and then compared together. The overall thermal structure of the dry-type air-core reactor when working under forced convection is designed according to the final result.
|
Related Dissertations
- Study on Contact Fatigue Life Based on Grease Variation with Temperature,TH117.22
- Simulation Analysis on Temperature Stress of RCC Arch Dam and Its Construction Joints Design Research,TV642.2
- Analysis and Study of Abutment Stability in Concrete High Arch Dam by Three-Dimensional Nonlinear Finite Element Method,TV642.4
- Numerical Simulation and Strength Analysis in Plug-in and Jet-stream Hot-wind Furnace,TF578
- Analysis of Tunnel Heat-harm and Temperature Field Simulation in Coal Mine Area,TD727
- The Study on the Vestibular 3d Reconstruction of Guinea Pig and the Numerical Simulation of Temperature Field,R764
- Simulation and Analysis of Shield Tunneling Method Construction for Subway,U455.43
- Simulation Numerical Study of Thermosyphon Technology to Massive Concrete Temperature Control Application,TV431
- Research on Temperature Control Feedback of Concrete Dam Based on Distributed Optical Fiber,TV698.1
- Three-dimensional temperature field acoustic tomographic reconstruction System,TH811
- The Numerical Simulation of the Steel Slag Which is as a Large Volume of Foundation Filler in Panzhihua Iron and Steel Company,TU521.4
- Measure and Analyse on Thermal on Thermal Field of Asphalt Pavement,U416.217
- Study on Assembly Variation Analysis for Thin-Wall Composite Aerostructures,TB332
- The Large Concrete Hydration Heat Temperature Effects Research of the Cable Stayed Bridge,U441.5
- Study on the Seasonal Frozen Roadbed Temperature and Deformation of Kangding Section of Sichuan-Tibet Highway,U416.1
- The Research on Temperature Distribution of Asphalt Pavement in Gansu Province,U416.217
- Research on Mechanical Behavior of Combined Sections Used in Steel-Reinfouced Concrete Pillar Base,U441
- Varying analysis considering shear lag effects of variable cross-section PC cantilever box girder,U448.213
- High-speed rail mass concrete cable-stayed bridge Tazuo three-dimensional temperature - stress field analysis and construction control,U444
- Body Structure Security Simulation and Assessment of Operating Coach Frontal Impact,U467.14
- The Simulation Research and Safety Assessment of Operating Coach During Side Impact,U467.14
CLC: > Industrial Technology > Electrotechnical > Transformers, converters and reactors > Reactor
© 2012 www.DissertationTopic.Net Mobile
|