Dissertation > Excellent graduate degree dissertation topics show

Study on Measuring the Grounding Resistance by Adopting Multi Current Auxiliary Electrodes in CDEGS

Author: BianZhiWen
Tutor: WenYuanFang;XuTao
School: Huazhong University of Science and Technology
Course: High Voltage and Insulation Technology
Keywords: grounding grid grounding resistance three-electrode method multi-electrode method CDEGS
CLC: TM862
Type: Master's thesis
Year: 2011
Downloads: 76
Quote: 0
Read: Download Dissertation

Abstract


Grounding is a fundamental gurantee and crucial measure to the reliable operation of power system, the safety of electrical equipment and operating personnel. The value of grounding resistance is a very important parameter indicating the validity and safety of grounding system. Thus, it is very vital to measure the value of the grounding resistance accurately.Nowadays, three-electrode method is mainly used by State Grid of China. However, the current electrode must be located far from the grounding system using the three- electrode method in order to improve the accuracy of measuring the grounding resistance. Sometimes, the distance from the current electrode to the grounding system can’t be set long enough because of the topography, which results in that the distribution of the electrical field on the surface of the earth changes a lot and leads to error increase of measuring the grounding resistance. Due to the exsiting problem mentioned above, the predecessor proposes the multi-electrode method to measure the grounding resistance. The multi-electrode method which means that there are several current electrodes around the grounding system, makes the distribution of the electrical field close to true value.The details of the three-electrode method are introduced, and the distribution of the electrical field is theoretically deduced and studied respectively using three-electrode method and multi-electrode method. The general formula of the position of zero-potential points and compensation points are deduced when there are n electrodes around the grounding system.In order to study the differences between the measured values using three-electrode method and multi-electrode method, the comparison and analysis of the measured values and true value is made using three-electrode method, four-electrode method, five-electrode method and six-electrode method, after the simulation and calculation based on the CDEGS which is famous for measuring the grounding resistance in the world. The results indicates that the electrical-field distribution of multi- electrode method is closer to true fact than that of three-electrode method, and measured-value inaccuracy of multi-electrode method is smaller than that of three-pole method, when the distance from the current electrode to the grounding system is the same. Furthermore, the measured-value inaccuracy of three- electrode method is vey big, when the current pole is very close to the grounding system. On the contrary, the measured-value accuracy of multi-electrode method remains high under the same condition.

Related Dissertations

  1. Calculation of Grounding Systems,TM862
  2. Design and Application for Jiangxi 200kV Transmission Line Towers Grounding Device,TM862
  3. Study on the Novel Line Selection of Singel-Phase-Grounded in the Small Current Earth System,TM862
  4. Study on the Electrical Performance of the Grounding Grid Based on Computer Clusters,TM862
  5. Research of Lightning Protection and Grounding Technology about Mountain Area Microwave Station,TM862
  6. Research on the Substation Grounding System and Analysis of Fault Diagnosis,TM862
  7. Research on the Method To Measure Grounding Resistance of Substation with Short Lead Wire Current Electrode,TM934.15
  8. Research and Design on Grounding System of Huizhou Pumped-storage Power Station,TV743
  9. The Research and Design on the Measurement of Impact Grounding Resistance Based on DSP,TM934.15
  10. The Study and Calculation of Grounding Grid Surface Potential Distribution and the Gradient,TM862
  11. Panzhihua Iron and Steel Plant Measurement of Grounding Grid Impulse Grounding,TM862
  12. The Research on Lightning Protection of 110kV Transmission Lines in Guizhou,TM862
  13. Research on Reform Measures of Grounding Networ of Jinjiang Hydropower,TV734
  14. Selection of Resistance Reducing Schemes and Grounding Materials in Substation Grounding System,TM862
  15. The Research on Calculation of the Impact of Ground and Measurement of Impulse Grounding Resistance,TM862
  16. Calculation and Improvements of Large Grounding Grid Surface Potential Distribution,TM862
  17. Analysis of the Effect Factors of the Measurement of Grounding Resistance,TM862
  18. The Research on Lightning Protection of 110kV Transmission Lines in Chizhou,TM862
  19. Design of Apparatus for Measuring Grounding Impedance Based on the Impulse Current,TM934.7
  20. Dading Square 220KV substation grounding network transformation research of new technologies,TM862
  21. The Engineering Design of Substation Grounding System in Wuhai District,TM862

CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage protection devices
© 2012 www.DissertationTopic.Net  Mobile