Abstract


Countries UHV power grid , intelligent substation construction , electrical equipment , intelligent degree of digitization has become increasingly high , the new electronic power transformer has begun to replace the traditional electromagnetic power transformer , power system measurement and an important cornerstone of the measurement . Reliable operation of the power system , the digital output of the electronic transformer check is a very important part . Domestic and foreign research institutions and enterprises gradually introduced a the experimental calibration system . Monitoring the check online monitoring system , in this article in accordance with IEC61850-9-2LE Statute , to build an electronic transformer , electronic transformer digital output can be used in the production of large quantities checksum and run online . The system runs on the parity check mode , the standard analog signals of field data acquisition unit for the digital signal , the the collected digital signal combining unit , to send to the system host computer via Ethernet broadcast together ; software modules through the network listens to receiving data packets, the calculated ratio on the two -way signal to complete the calibration process . When equipped this checksum and monitoring systems host access site Ethernet , the system can be based on the numeric value and quality parameters of sampled values ??, online monitoring tasks to complete on-site transformer equipment . The system entirely in C, C # language development , to avoid dependence on foreign commercial software ; introduction of the FFT the bimodal spectral correction algorithm effectively reduces the non- synchronous sampling and Fourier transform due to measurement error . Finally, through the simulation experiment to prove the reliability and accuracy of the system .

Related Dissertations

  1. Research of Embedded Merging Unit Based on IEC61850,TM45
  2. Design of Merging Unit Based on Embedded FPGA,TM45
  3. Digital substation relay protection system reliability design technology,TM76
  4. Buck type AC chopper regulator of,TM46
  5. Rogowski coil electronic transformer design digital integrator,TP321.2
  6. Conventional substation intelligent transformation project implementation plan of,TM76
  7. SEPIC transformer three-level intelligence research,TM42
  8. Digital substation down power electronic transformer in applied research,TM76
  9. Intelligent Substation number of key technology research and application,TM63
  10. Study on Electrical Transformer Calibrator,TM45
  11. The On-Line Monitoring System of Electronic Transformer,TM45
  12. Impact Study of Electronic Transformer Application on the Relay Protection,TM45
  13. Research and Application of Smart Substation Related Technology,TM63
  14. Research of Merging Unit Based on IEC61850,TM73
  15. Research and Implementation of Safety Valve On-line Test System,TH134
  16. Program Design and Implementation on the Digital Substation for Harbin District,TM63
  17. Digital substation in Jinan grid,TM632
  18. Maneuvering Target Detection of OTH Radar,TN953
  19. Research on the Key Technologies of Digital Substation,TM63
  20. Design and Relization of Lightning Location System Based on CPLD,P427.32

CLC: > Industrial Technology > Electrotechnical > Transformers, converters and reactors > Transformer
© 2012 www.DissertationTopic.Net  Mobile