Magnetic resonance imaging technology is a non - destructive diagnostic techniques based on nuclear magnetic resonance principle . By performing the cross-sectional imaging or three - dimensional imaging , it can be obtained the anatomical structure and functional structure of tissues and organs , in order to provide diagnostic information on the lesion . Magnetic resonance imaging technology has been widely used in clinical diagnosis and basic scientific research is an important tool of the 21st century medical and biological research . T2 relaxation time measurements is an important work in magnetic resonance imaging , T2 relaxation time is often used to identify tumors and distinguish its nature . Currently, most of the T2 relaxation time quantitative maps are superconducting MRI system , but due to the expensive superconducting system price and maintenance costs later domestic hospitals lower penetration of magnetic resonance imager . Low field permanent magnet MRI system due to its low price and maintenance costs later , and the many advantages of the open magnet increasingly wide range of applications , has become a the domestic routine clinical diagnosis mainstream models . System compared to the high-field , low field permanent magnet systems due to its shorter development time , the basis of the low-field measurement data is lacking, In addition , due to its own characteristics , such as low signal-to-noise ratio , field uniformity is poor , so suitable for high field measurement method may not be suitable for low field . So , to find a fast and accurate method suitable for low field T2 quantitative spectra measurement method for clinical and low - field system makes sense. Low signal to noise ratio for low-field magnetic resonance system , this paper proposes a new , more effective T2 quantitative map measuring post-processing curve fitting method : T2 signal-to-noise ratio optimized adaptive curve fitting algorithm . The method by estimation, adaptive optimization of the number of echoes , the curve fitting for the corresponding body element so as to achieve the purpose of optimizing T2 SNR improved , so that the accuracy of quantitative Spectrum T2 T2 values ??at each voxel . Computer simulation , phantom experiments and human experimental results show that the truncated curve fitting method , this method can get the signal-to-noise ratio higher measurement results more accurate T2 quantitative map .
|
Related Dissertations
- MRI Guoded Experimental Cryoablation of Rabbit’s Sciatic Nerve for MRI and Pathology Contrast Study,R445.2
- Research on Detecting Optical Fiber Geometric Parameter Based on Machine Vision,TN253
- The Clinic Value of Diffusion Weighted Whole Body Imaging with Background Body Signal Suppression (DWIBS) Compared with hPET/CT,R445.2
- A Study of Wallerian Degeneration in Cortico Spinal Tract after Cerebral Infarction by fMRI,R445.2
- A Volumetric Study of External Capsule, Extreme Capsule and Inferior Frontal Gyrus White Matter in First-Episode Paranoid Schizophrenia,R749.3
- 3.0T BOLD MR techniques on acute unilateral ureteral obstruction of renal damage,R693.2
- MR diffusion weighted imaging in Application Value of osteonecrosis,R681.8
- Preliminary Study of the MRI Diagnosis and Differential Diagnosis in Multiple System Atrophy , Progressive Supranuclear Palsy and IPD,R445.2
- The Application of STIR-FLAIR and T2W-SPIR for Diagnosing the Orbital Lesions: a Contrast Study,R777
- Application of Functional MR Imaging in Diagnose for Prostate Cancer,R737.25
- The Exploration and Application of MR Imaging in Patients with Lateral Epicondylitis of the Elbow,R681.8
- MR Imaging of Brain Glioma in Rat Model Using Transferrin-conjugated SPIONs as a Specific Contrast Agent,R739.4
- Pipeline magnetic flux leakage detection signal reconstruction technology within,TN911.23
- Lacustrine soft soil physical and mechanical properties and the creep characteristics of,U212.22
- Measurement of Liver Fatty Content by CT and MR Imaging Technology: An Experimental Study,R816.5
- A Comparative Study of the 256 -slice spiral CT and magnetic resonance imaging evaluation of left ventricular function,R816.2
- Imageological Evaluation on Knee Joint Injury and It’s Reconstructive Structures,R816.8
- Clinical Effects, Imaging Study and Treatment of TOT Procedure Combined with Modified Pelvic Floor Reconstruction on Female Stress Urinary Incontinence,R699.7
- The Study of MRU Finding in Urinary Tract Obstruction,R691.2
- Autopilot system for vision-guided AGV,TP391.41
- Curve Fitting of Time Series with Equidistant Sampling Points,O211.61
CLC: > Medicine, health > Clinical > Diagnostics > Diagnostic Imaging > Magnetic resonance imaging
© 2012 www.DissertationTopic.Net Mobile
|