Dissertation > Excellent graduate degree dissertation topics show

Research on Three-Phase Three-Wire Shunt Active Power Filter Based on DSP

Author: BaiYang
Tutor: YangJiaQiang
School: Zhejiang University
Course: Motor and electrical
Keywords: Shunt Active Power Filter Harmonic Digital Signal Processing Digital Low-pass Filter LCL Filter Current Loop Control
CLC: TN713.8
Type: Master's thesis
Year: 2012
Downloads: 231
Quote: 0
Read: Download Dissertation

Abstract


In the process of industrialization and urbanization in China, electric power industry has achieved considerable development. However, due to the use of a variety of power electronic devices, numerous reactive power consumption and harmonic pollution sources have emerged in the parts of generating and transmitting of electricity and power utilization terminals. Problems of harmonic suppression and reactive power compensation have become the hotspot of current research. As a comprehensive control device, active power filter has received extensive attention and research. This paper do systemic and deep research on the harmonic detection method, main circuit design method and current closed loop control in the three-phase three-wire active power filter.The reasonable harmonic detection algorithm should be confirmed first in the use of active power filter. This paper analyzed the mechanism of the SRF method and PQ method decomposition harmonic currents, summed up the advantages and disadvantages of the SRF method and PQ method in harmonic detection. Meanwhile, to deal with the time domain harmonic detection algorithm of active power filter, a high performance digital low-pass filter is present based on the comparison and analysis between infinite impulse response filter (IIR) and moving average filter (MA), which can satisfy the requirements of dynamic response and filtering accuracy simultaneously by cascaded MA filter and Butterworth filter optimally. The proposed high performance filter can make full use of Butterworth filter to achieve more precise filtering result and improve dynamic response by using MA filter with its narrow transition zone and fast dynamic response.Active power filter need reasonable main circuit design to ensure the current closed loop compensation effect. The detailed principle of LCL filter is introduced in this paper. Based on analyze of the influence of gird voltage on the LCL filter, the necessity and feasibility of grid voltage feed-forward control is present. To some extent, LCL filter design is difficulty, then the general design guidelines and procedures of LCL filter are introduced in this paper. LCL filter is designed in accordance with the actual needs. Furthermore, the mathematical model of APF based on the LCL filter in three phase static field is established.For grid connected inverters such as active power filter, the current loop control is the core issue. This paper present detailed analysis of the PID control in LCL filters control and obtained a stable PI controller through the root distribution analysis. Simulation results show that the PI controller is effective and practical. The experimental hardware platform and software processes are introduced briefly at the end of this paper. Experimental results show the active power filter technique route mentioned in this paper is effective and practical.

Related Dissertations

  1. Study of Three-Phase AC Chopper Surge and Its Harmonic Elimination Technology,TM423
  2. Water in oil emulsion of water hit the harmonic the demulsification dynamics analysis and its mechanism,X703
  3. Hybrid distributed power distribution system for Linyi Study on the Impact,TM712
  4. Proofs and Applications of Some Combinatorical Identities,O157
  5. Control Strategy for Single-Phase Grid-Connected Inverter with LCL Filter,TM464
  6. Research on Single-phase Photovoltaic Grid-connected System,TM464
  7. Study on Protection Scheme of Propulsion System and Power Supply in High Speed Maglev Vehicle,TM773
  8. The Research and Design on the Non-Isolated Single Phase Grid Inverter,TM464
  9. Research on Three-Phase Grid-Connected Inverter System with Harmonic Controller,TM464
  10. The Research of Harmonic Filtration of Large Data Center,TM711
  11. Harmonic analysis of structural mechanics reducer,TH132.46
  12. Research on Embryonic Array for Digital Signal Processing,V443.1
  13. Based on single-phase bridge topology active PFC inverter heat pump thermal station power,TM46
  14. Study of Harmonic Compensation Device Based on a Combination of TCR and TSF,TM761
  15. DC bias magnetic transformer,TM401
  16. AC DC Hybrid Transmission System Harmonic Analysis,TM711
  17. High-frequency Soft-switching Rectifier Voltage Regulator Circuit Technology and Power Factor Crection,TM46
  18. The New Functional Complexes Based on Tartaric Acid,O621.13
  19. Regularity Results for Div-Curl Fields and Applications,O174.3
  20. Solving large-scale non- symmetric matrix eigenvalue problem Weighted Arnoldi method,O241.6
  21. Design of Rational Bézier Minimal Surface: Finite Difference Method,O186.11

CLC: > Industrial Technology > Radio electronics, telecommunications technology > Basic electronic circuits > Filtering techniques,the filter > Active filter
© 2012 www.DissertationTopic.Net  Mobile