Dissertation > Excellent graduate degree dissertation topics show
Desigin and Research on Folded Plate Indirect Evaporative Cooler in Textile Air Conditioning
Author: ZuoDanYang
Tutor: ZhouYiDe
School: Zhongyuan Institute of Technology
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: Indirect evaporative cooling Textile Air Conditioning The efficiency of heat transfer Orthogonal experiment Single factor experiment.
CLC: TU831.4
Type: Master's thesis
Year: 2011
Downloads: 22
Quote: 0
Read: Download Dissertation
Abstract
|
Large textile factory installed power , water power consumption from 15% to 25% of the total energy consumption of the mills air conditioning energy consumption of the total plant , textile mills air conditioning energy saving lot of sense to reduce the cost of production . In this paper, the status quo of the current textile mills of the high energy consumption of air conditioning as well as indirect evaporative cooling technology application status , based on widely absorbing domestic and foreign advanced technology , the development of the textile folded plate indirect evaporative cooler . By orthogonal experiment to study the impact a major factor in the folded plate indirect evaporative cooler , then through the single factor experiment to identify the main factors impact on the efficiency of heat transfer law . Fold plate indirect evaporative cooling structure size is determined by the design calculations and checking calculation ; Next by theoretical analysis and calculation for selection of experimental equipment required to build a folded plate indirect evaporative cooler performance test bed experiments study the impact of various factors on the efficiency of heat transfer , folded plate indirect evaporative cooler heat exchanger efficiency impact more significant factor in the use of primary air side of the wind speed range analysis method, folded plate indirect evaporative cooler heat exchanger efficiency determined by orthogonal experiments have a greater impact on a relatively small interval of water distribution and secondary wind speed ; Finally, the single factor experiment to determine how the impact of significant factors that affect the efficiency of heat transfer : thermal efficiency wind speed , and inversely proportional to the spray interval with two times the wind speed, an air inlet dry bulb temperature with the secondary air inlet is proportional to the temperature difference between the wet bulb temperature ; channel resistance and Winds proportional . A wind velocity, the optimal value of the secondary wind velocity was 2.5m / s , the cloth water should be continuous cloth water in the nozzle arrangement under certain circumstances , the size of the water quantity to wet the heat exchanger plate surface prevail . Experimental results show that : the primary air velocity of 2.5m / s , can handle 1620m ~ 3 / h primary air , in an air inlet temperature 32 ° C , a secondary air inlet to the wet-bulb temperature of 28.5 ° C , the heat transfer efficiency of up to 32% ; in an air inlet temperature of 38 ° C , the secondary air inlet wet bulb temperature 28.5 ℃ , the heat transfer efficiency of up to 40% . Its direct application to savings in the textile mills air conditioning or combined with mechanical refrigeration cooling capacity , reducing the air conditioning running costs , has a broad application prospects .
|
Related Dissertations
- The Setting Bases of Working Pressure in LNG Systems and Orthogonal Experiment Design of Heat Exchangers,TQ051.5
- A New Method of Separating HDPE and PP with an Improved Barrier Screw,TQ320.52
- Optimization Study of Sewage Source Heat Pump Heating System in Lanzhou City,TU831
- Establishment a Multiplex PCR Method for Detection of Four Foodborne Pathogens,R155.3
- Optimum Design of the Dew Point Indirect with Direct Evaporative Cooling Air Conditioning Unit,TU831.4
- Energy Efficiency Analysis of Solution Heat Recovery System of Process Exhaust Air in Cigarette Factory,TU834.53
- Wetland plant rhizosphere microbial identification LF2 , medium optimization and artificial wetlands in the Application Effect,X703
- Numerical Simulation of Injection Molding and Multi-objective Optimization,TQ320.662
- Treatment of Hexavalent Chromium in Groundwater Using Zero-Valent Iron Nanoparticles,X523
- Numerical Study of the Effect of Building in Power Plant on Air-cooling Island’s Performance,TM621
- Optimizing Research on Direct Air Cooled Turbine Unit and Air Cooled Island’s Structure of Wind Defend Wall,TM621
- Effects of Temperature on Parts’ Wall Thickness Homogeneity in Extrusion Blow Molding,TQ320.663
- Preparation and Study of Drug CA Solid Dispersion Sustained-release Capsule,R944
- Research and Application of the Methods on Fire Numerical Reconstruction for Fire Investigation,X928.7
- Technical Study on Automobile A-alloy Hub Power Spinning Forming Process,U463.343
- Optimization and Evaluation of Type Ⅱ Diabetes in C57BL/6J Mice,R587.1
- Preparation of Water Based Silanization Solution and Its Application,TG174.4
- A Study on Classification and Identification of Nine Yunnan Lyophyllum Species Based on ITS Sequences of rDNA and the Physiology of Yunnan Lyophyllum,S646.190.1
- Treatment of DDNP Wastewater with Coagulation-fenton Process Andwhite Rot Fungi,X703.1
- Preparation and in Vitro Transdermal Permeation on Minoxidil Nanostructured Lipid Carriers,R96
CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning > Air-conditioning machinery and equipment
© 2012 www.DissertationTopic.Net Mobile
|