Dissertation > Excellent graduate degree dissertation topics show

The Operation Condition and Control Measure of the Water Supply

Author: PanHaiZuo
Tutor: HuangJiGuo;XiaoShuHong
School: Jilin University
Course: Environmental Engineering
Keywords: Groundwater And manganese removal System transformation
CLC: TU991
Type: Master's thesis
Year: 2011
Downloads: 13
Quote: 0
Read: Download Dissertation

Abstract


Rich reserves of groundwater , water quality and stability , an important part of the city water supply . But when excessive iron and manganese concentrations in groundwater or other contamination problems will undoubtedly affect the water quality of the city water supply . In this paper, the problem of excessive levels of manganese in groundwater investigation and analysis of the D city in the southern region groundwater source . The municipal water company mainly iron, manganese removal process , a pilot experiment , to provide the basis for the technological transformation of the municipal water company , to ensure high-quality water supply to the user . This thesis is based on access to water monitoring data and field survey results , A water and B water manganese content in water quality monitoring data collated Results A water and B water export water manganese content in an average of about 0.15mg / L , has exceeded the standard requirements (≤ 0.1mg / L). Determine water effluent manganese content exceeded the water manganese content exceeded the main reason for the exploitation of groundwater ( 1 ) is not preferred short , ② oxidation of contact time , ( 3 ) the use of quartz sand as a filter ④ filter fast , affecting the filtering effect . Underground sources of manganese content exceeded the corresponding countermeasures were proposed , mainly ① Select the exploitation of groundwater ,封停high manganese content of the deep well , row ② install deep well aeration device ( 3 ) The use of manganese sand as a filter , ④ to filter operating conditions adjust , test , achieve constant speed filtering . The experimental results showed that : After take封停poor water quality wells running Tseng A, B, C classification ; oxidation aeration time of 15 minutes ; single stage manganese sand filtration ; The canister just finished backwash of the raw water valve opening degree 1/ 8 other valves normal ; running after 12 hours , adjust the filtration tank valve opening degree to 1 / 4 ; the cumulative run to 24 hours after the valve opens to 1/2 ; the cumulative run to 36 hours after the valve opens to 3/4 ; raw water fully open and above governance measures accumulated 48 hours after the run , the manganese content in the finished water is reduced to 0.072 mg / L, to meet the standard requirements . After the renovation project of the municipal water company , resulting in a better economic and social benefits, improve water quality , and to ensure the continuity of the water supply , and reduce the impact on the user , the water supply company to the public \, continuous commitment of the water supply , maintenance D City area social stability and promote economic development , an important foundation for one of the conditions people live and work in peace and contentment .

Related Dissertations

  1. Crude oil loading system transformation project management research,F284
  2. Tengzhou GIS-based water management system design and implementation,TV213.4
  3. Coal mining impacts on groundwater numerical simulation,TD741
  4. Application of Feflow to Groundwater Flow Simulation,P641.8
  5. High water on the open pit slope stability study effects,TD804
  6. Legal issues of the protection of groundwater resources in Shandong Province,TV213.4
  7. Evaluation of Shallow Groundwater Quantity in Handan County Based on Visual MODFLOW,P641.8
  8. Analysis of Characteristics and Ecological Effects of Shallow Groundwater Fluoride Pollution in Typical Areas of Liao River Basin,P641.8
  9. Groundwater Numerical Simulation of Tanghai County, Hebei Province,P641.8
  10. The Research on Physical Model Experiment of the Load-Unload Response Ratio Pattern and Its Failure Mechanism of Debris Landslide Induced by Rainfall,P642.22
  11. Analysis of the Degenerated Mechanism of Haloxylon Ammodendron Populations in Gurbantunggut Desert,Q948
  12. Study of the Impact on Groundwater Environmental about Shijiazhuang Refinery Upgrade Project,X523
  13. Investigation of Organic Pollution Impact on Groundwater During Mine-filling Process with Gangues,X523
  14. Design and Simulation of Groundwater Monitoring and Repairing Control System Based on Control Configuration Software,X832
  15. Sthdy on Numerical Simulation and Its Application of Mine Underground Water,TD741
  16. Research on Bioremediation of Fe2+ and Mn2+ and the Preparation of Compound Microorganisms,TU991.2
  17. Study on Combined Operating of Underground Water Direct Cooling and Ground Source Heat Pump in Villages,TU831.6
  18. Test Study and Finite Element Analysis of the Work Mechanism of the Rock Anti-Float Anchor,TU472
  19. The Research on Biological Characteristics and Ecological Culture Techniques of Cultured Paa Boulengeri,S966.39
  20. The Study of the Chinese Rural Individual Plot System,F321.1
  21. The Legal Protection of Mining Area Groundwater Resources in Our Country,D922.66

CLC: > Industrial Technology > Building Science > Municipal Engineering > Water supply project ( on the Water Works )
© 2012 www.DissertationTopic.Net  Mobile