Dissertation > Excellent graduate degree dissertation topics show

Study on the Effects of Internal Fixation System of Femur Facture with Plate

Author: LiuChunXiao
Tutor: ZhuDaiGuo
School: Dalian University of Technology
Course: Biomedical Engineering
Keywords: FEM Plate Internal fixation Fixation effect
CLC: R687.3
Type: Master's thesis
Year: 2011
Downloads: 31
Quote: 0
Read: Download Dissertation

Abstract


Plates have been widely used in internal fixation for femur fracture healing in clinical. The main problem of current clinical work is how to choose a reasonable fixation style, increase the effect to promote fracture healing, reduce the negative effects to bone and ensure the internal fixation in effect.We investigated the effects of each constituent issue in internal fixation system with numerical simulation, which can provide reference for solving the clinical problem of internal fixation system. For example bone plate, screws, intact bone and broken bone.Using three-dimensional finite element method, we analyzed the internal fixation system of femur cross-broken. First, three kinds of bone fracture plate were selected and different screw missing fixation styles were considered, the effects on the femoral fracture system were analyzed. Second, the most optimal fixation style of NiTi alloy, Ti-6Al-4V and Ti plates and corresponding plate fixation were gotten by the analysis and the influence of plate material type to fracture system were also studied. The third, the effects of these three plates to the broken femur recovery were also presented.The simulations show that the length and screw missing fixation styles both influence the stability of fixation system, the stress shielding degree of femur and the stimulative effect to broken femur recovery. The optimal plate length is five to six times the diameter of the broken bone and the best internal fixation is the fixation without screw missing. NiTi alloy is a more suitable material to be used for bone plate, it not only can reduce the stress shielding effect but also can provide effective deformation stimulation to the bone. These issues benefit to the recovery of broken bone. With the increasement of material elastic modulus, the speed of fracture recovery decreases. The broken femur with bone fracture plate of NiTi alloy has the fastest recovery rate of three internal fixation systems. This study is more important for clinical to select internal fixation styles and to design the new type plate.

Related Dissertations

  1. Analysis of Flexspline Stress and Tooth Wear in Harmonic Gear Drive,TH132.43
  2. Heat Transfer Performance of the Metallic Honeycomb and Regenerative Cooling Channel,V215.4
  3. The Effect of Current Density and Electric Field on Ni and Its Alloy Electrodeposition for Copper Crystallizer,TQ153.2
  4. Marine Boiler Superheater Tubes Expansion Port Stress and Strain Analysis,TQ051.5
  5. Research and Simulation on Droplet Distribution in φ38mm Pulsed Sieve-Plate Extraction Column,TQ028.3
  6. Finite Element Analysis and Optimization Design of a Tractor Cab,S219.02
  7. Steering Mechanism and Hydraulic System for the Electronic Control Hydraulic Power Steering System of Tractor,S219.02
  8. Multi-pin Internal Fixation of Calcaneal Fractures in Finite Element Analysis,R687.3
  9. The Recognization of License Plate Based on EMD and Its Application,TP391.41
  10. Solid-State Fermentation Process for Production of Antimicrobial Lipopeptide by Bacillus Amyloliquefaciens ES-2-4,TQ936.16
  11. Comparative Efficacy with Locking Plate and the Normal Plate for Treatment of Elderly Tibial Plateau Fractures in Schatzker Ⅱ, Ⅲ Type,R687.3
  12. Research on Control Algorithm of Ball&Plate System,TP13
  13. Study on Analysis of Microflora and Predictive Growth Model of the Major Spoilage Microorganisms in Pasteurized Milk,TS252.1
  14. The Relation of the Height of the Remnants of Thoracolumbar Tuberculosis and Selection of Mode of Anterior Internal Fixation,R687.3
  15. Comparison of PFNA and DHS in Treatment of the Elderly Intertrochanteric Femur Fractures,R687.3
  16. The Efficacy of Locking Plate and Anatomic Plate in Treatment of Distal Femur Fractures,R687.3
  17. Preliminary Effects of Clavicular Hook Plate Technique on Treating Acromioclavicular Joint Dislocation,R687.3
  18. Analysis on Curative Effect of Internal Fixation of Femoral Shaft Fracture Intramedullary Interlocking Nail and Compression Plate,R687.3
  19. Open Reduction and Internal Fixation of Displaced Scaphoid Fractures,R687.3
  20. Effect of Anatomic Locking Compression Plate and Dynamic Hip Screw in Treatment of Femoral Intertrochanteric Fracture,R687.3
  21. Open Reduction and Internal Fixation with the AO Anatomic Plating Systems for Type C Fractures of the Adult Distal Humerus,R687.3

CLC: > Medicine, health > Surgery > Orthopaedic Surgery ( movement system diseases,orthopedic surgery ) > Orthopedic surgery and surgery > Bone surgery
© 2012 www.DissertationTopic.Net  Mobile