Dissertation > Excellent graduate degree dissertation topics show
Development and Research of Intelligent Ultrasonic Heat Meter
Author: YaoBinBin
Tutor: ZhangHongJianï¼›ZhouHongLiang
School: Zhejiang University
Course: Detection Technology and Automation
Keywords: Calorimeter Ultrasonic wave TDC-GP21 Time difference method Flow Zero drift
CLC: TH81
Type: Master's thesis
Year: 2012
Downloads: 106
Quote: 0
Read: Download Dissertation
Abstract
|
Calorimeter is used to measure the heating system and a key instrument of release or absorb heat energy flow through the heat exchange system . With the full implementation of the national heating household metering and charging system , the development and application of heat meters in China will be the formation of the large-scale structure of the industry , has a very broad market prospects . The traditional mechanical Calorimeter there , can not fully meet the market demand for a series of problems of high water quality requirements , pressure loss , mechanical devices easy to wear , and poor anti-interference ability . With the development of modern ultrasonic detection technology , ultrasonic heat meters in the country has been more and more research and application . There is no doubt that the ultrasonic heat meters where future Calorimeter trends . Domestic production ultrasonic heat meter run stability and measurement accuracy , there are some shortcomings to be further studied and improved . In order to analyze the the inadequacies reasons ultrasonic heat meter measurements exist , on the basis of broad access to the Calorimeter related domestic and foreign literature , combined with ultrasonic heat meter works and design procedures , the paper developed a transit-time measurement principles and TDC-GP21 measurement chip smart ultrasonic heat meters . Problems exist for ultrasonic heat meters , the design of experiments carried out in-depth research . The main characteristics of this paper are as follows : (1) processing software to optimize flow measurement procedures to improve the accuracy of flow measurement . The influence of temperature on ultrasonic flow measurement software correction . (2) from the ultrasonic transducer matching experiments found that using paired ultrasonic transducer can be reduced ultrasonic transducer structure itself is brought to an ultrasonic signal measurement error , improve the measurement accuracy . Zero drift problems from ultrasonic calorimeter traffic measurement experimental study found that the ultrasonic transducer is an important factor leading to measurement zero value exists . Ultrasonic transducer performance directly affect to the the calorimeter measurement accuracy .
|
Related Dissertations
- Numerical Investigation of Effects of Boundary Layer Suction on the Performance of Diffusion Cascade,TH453
- Study of the High Temperature Gas-Liquid Two Phase Flow Rate Proportional Conrtol Valve,V233.2
- The Flow Theroy Investigation of Compressor Cascade with Split,TK474.8
- Influence of over Fired Air on Gas-Solid Flows in a W-Shaped Flame Boiler,TK229
- Study of Effect of High Temperature Seperator on Hydrodynamices in CFB Boiler Furance,TK229.66
- Study on Gas-Solid Two-Phase Flow in Spouted Beds,TK173
- Numerical Analysis of Flow Process in a Molten Carbonate Fuel Cell,TM911.4
- Research on Feature Extraction and Classification of Doppler Ultrasonic Blood Flow Signals of Wrist Radial Artery,TP391.41
- Research on Visual Detection and Tracking of Mobile Robots,TP242.62
- Development of Software Platform for Designing Automatic Test System,TP274
- Research on Melamineanalysis Method in Milk Powder and Establish the System of Rapid Determination,O657.3
- Fast Determination Method Research of Bisphenol A in Food Packing Material,TS206.4
- Investigation on Gasification Characteristics of Pulverized Coal in Entrained Flow Gasifier Based on Flameless Oxidation,TQ546
- Study of the Treatment of Printing and Dyeing Wastewater Using a Pilot-scale Combined Process of Multi-stage Anaerobic Phases and Cross Flow Aerobic Sludge Reactor,X791
- Smart Control Research in Paddy Drying Based on BP Neural Network,S226.6
- The Effect of Frequencycontron on Flow Fields Environment in Bulk Curing Barn and Quality of Flue Cured Tobacco,S572
- College Teachers Flow Mechanism Research in Our Country,G645.1
- The Study on R-M Instability of the Material Interface in Gas-water Compressible Flow,O359.1
- Study of Smoke Flow of Enclosed Space Fire with Horizontal Openings,X928.7
- Influence of Nitrate Concentrations on the Production of N2, N2O, NO, and CO2 by Soil Cores During Anaerobic Incubation,X131.3
- Intrusion detection based on the ultrasonic echo envelope in the military security patrols,E919
CLC: > Industrial Technology > Machinery and Instrument Industry > Instruments, meters > Thermal measuring instruments
© 2012 www.DissertationTopic.Net Mobile
|