Dissertation > Excellent graduate degree dissertation topics show
Research and Development of Triple Channels Infrared Flame Detector
Author: YuanJiDe
Tutor: HuangWenJun
School: Zhejiang University
Course: Control Theory and Control Engineering
Keywords: Tri-band infrared flame detection Flame recognition algorithm Sensitivity Reliability Prototype
CLC: TH89
Type: Master's thesis
Year: 2012
Downloads: 62
Quote: 0
Read: Download Dissertation
Abstract
|
The state-of-the-art fire detection technology has great significance to ensure the safe production of petrochemical sites . The existing fire detectors exist long response time , low sensitivity , detection reliability and low , it is difficult to meet the the scene demanding requirements of complex industrial production . Of this study and the development of a new tri-band infrared flame detectors , focused on solving the problem : First, the proposed tri-band infrared flame detection program . Three infrared sensors to monitor based on the in-depth study of the the flame radiation spectrum , artificial heat sources and background radiation spectrum establishes flame , artificial heat source of interference and background radiation interference band . The probe response time is shortened by the early fire detection signal characteristics of the infrared radiation material burning . Through the acquisition and analysis of interference information characteristics , improve the anti-jamming capability . Screening true flame flame flicker frequency signal to improve detection reliability . Secondly, the design of a high sensitivity tri-band flame recognition algorithm . The tri-band radiation signal strength increased detection range and attenuation , and logical relations are relatively stable . Determined through the analysis of the logical relationships between the three bands of radiation intensity infrared radiation source type , the distinction between the flame and infrared radiation signal , greatly increase the effective detection range of the flame signal , greatly improve the flame detection sensitivity . Finally, the DSP as the core , tri-band infrared flame detector hardware and software design . But due to limited time , only the development of the system prototype was tested in the prototype of the detection range , anti-interference ability . The test results show that the performance of the prototype , but relatively foreign advanced flame detection system is still a certain gap . The system can be further enhanced through the use of better performance of infrared sensors , and design the the better hardware circuit and infrared optical lens system , the overall detection performance .
|
Related Dissertations
- The Effect of Composite Additive on the SNCR,X701
- Research on the Teaching of Ditransitive Construction in Senior Middle School in the Perspective of Construction Grammar,G633.41
- Development and Preliminary Application of the Questionnaire on Emotional Labour of the Middle School Teacher,B841
- Study on a Pneumatic Manipulator Clamping Force Control System Based on H ∞ Control Theory,TP241
- The Analysis of Lolita Fashion Style Prototype and Its Application,TS941.2
- The Research on Reliability of Low-Voltage Power Line Communication,TM73
- Broken walnut shell force testing and virtual prototype design of the main components of walnut sheller,S226.4
- Preparation and Properties of Chitosan-based Thermosensitive Composite Hydrogel,R943
- Isolation and Identification of Avian Pathogenic Escherichia Coli from Chicken and Characterizations of Its Virulence-Associated Genes,S852.61
- Luoyang Land the Use and Ecoloqical Environment Construction Coordination Study,X171
- Cloning and Characterization of Photoperiod Sensitive Gene ZmELF4 in Maize,S513
- The Research and Application of Software Reliability Test for User Right Management System,TP311.53
- Research on Subsea Pipeline Repair Coupling,TE973
- Research and Application on Reliability Technology of Mine Hidrological Monitoring System,TD742.1
- Change and Value of Serum Soluble Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 in Acute Coronary Syndrome,R541.4
- Effects of Telmisartan on hs-CRP and HMW-adiponectinin Patients with Essential Hypertension,R544.1
- Study on Clinical Value of High-sensitivity Cardiac Troponin T Assay in Myocardial Infarction,R542.22
- Correlation Analysis between Coronary Lesion Severity and Peripheral Blood Cell CD34~+ Ratio in the Coronary Heart Disease Patients Complicating Diabetes Mellitus,R541.4
- The Study on Clinical Using of FISH and Cytology in Diagnosis and Surveillance of Recurrence in UC,R737.1
- Application and Significance of CISS Classification and TOAST Subtype on Ischemic Stroke (Attach 210 Cases Analysis),R743.3
- Ankle-brachial index combined ultra- sensitivity C-reactive protein determination of the value of coronary artery disease,R541.4
CLC: > Industrial Technology > Machinery and Instrument Industry > Instruments, meters > Other instrumentation