The Cleaning Effects of Denture Cleansers and Its Influence on Properties of Denture Base

Author: ZhangYanPing
Tutor: WuFengMing
School: Nanjing Medical University
Course: Clinical Stomatology
Keywords: denture cleansers Candida albicans biofilms denture base resin color stability surface roughness flexural strength
CLC: R783.6
Type: Master's thesis
Year: 2011
Downloads: 94
Quote: 1
Read: Download Dissertation

Abstract


Objective: To evaluate the capacity of five denture cleansers which are commonly used at home on reducing the Candida albicans biofilms activity and biomass. To provide references for choosing the operative denture cleanser.Methods: C. albicans strain SC5314 biofilms were formed on polystyrene, flat-bottomed, 96-well microtiter plates for 24 h. To confirm that the mature biofilms have been formed under the conditions of this experiment, crystal violet staining method was used. The biofilms were immersed in Polident, Victoria-C, Protefix, 0.2% chlorhexidine gluconate and Y-Kelin denture cleansers. Positive (immersed in sterile distilled water) and negative (no biofilm) controls were included. Each denture cleanser was further divided into 2 subgroups, either immersed for the time indicated by the manufacturers or for 12 h (overnight). The activity of the biofilms was then quantified using a formazan salt-based XTT reduction assay, and the biomass using a crystal violet assay.Results: In terms of reducing the biofilms activity, after the recommended time of immersion, reduction rate of the five denture cleansers were (%):( 80.2±3.6), (23.4±3.3), (81.3±1.0), (65.5±1.8), (66.6±3.5). Polident and Protefix were the highest (P <0.001), while Victoria-C was the lowest (P <0.001). After overnight immersion, except that the reduction rate of 0.2% chlorhexidine gluconate lowered, others increased (P <0.05), higher than 80%, especially Polident (88.8±4.4) %. In terms of reducing the biofilms biomass, after the recommended time of immersion, reduction rate of the five denture cleansers were (%):(38.2±10.2), (8.7±6.2), (22.0±2.6), (34.2±3.9), (24.7±8.0). Polident and 0.2% chlorhexidine gluconate were the highest (P <0.05), while Victoria-C was the lowest (P <0.01). After overnight immersion, the reduction rate of former three denture cleansers increased (P <0.05), especially Polident (56.8±4.8) %.Conclusion: Among the five denture cleansers, Polident exhibited the best effect on reducing the C. albicans biofilms activity and biomass. However, residual biofilm retention with a few living cells was still observed. Denture cleansers can improve their effects after overnight immersion except 0.2% chlorhexidine gluconate.PartⅡInfluence of denture cleansers on physical and mechanical properties of heat-curing denture base resinObjective: To evaluate the color stability, surface roughness and flexural strength of heat-curing denture base resin after its immersion in five denture cleansers which are commonly used at home, simulating a 180-day use.Methods: Thirty rectangular samples (64 mm×10.0 mm×3.3 mm) were prepared from heat-curing denture base resin according to ISO 1567-1999.They were immersed in Polident, Victoria-C, Protefix, 0.2% chlorhexidine gluconate, Y-Kelin denture cleansers and distilled water. The immersion time was indicated by the manufacturers. The procedure of immersion was repeated 180 times over a period of 6 days, simulating 180 days of cleansing by the patient. Color changes (ΔE) were determined by a colorimeter. After immersion, a surface profiler was used to measure the roughness. The flexural strength was measured using a 3-point bending test in a universal testing machine. Results: The color changes were significantly higher for the 0.2% chlorhexidine gluconate and Y-Kelin denture cleansers than the negative control group (P were 0.001, 0.005). TheΔE values quantified by the NBS (National Bureau of Standards) were classified as Slight in all groups (0.5-1.5). When comparing the surface roughness and flexural strength, no statistical significance was found among the different immersion procedures (P were 0.512, 0.969).Conclusion: It was concluded that immersion in 0.2% chlorhexidine gluconate and Y-Kelin denture cleansers influenced the color stability of heat-curing denture base resin, simulating a 180-day use, but were clinically acceptable. The two denture cleansers had no influence on surface roughness and flexural strength. Polident, Victoria-C, Protefix did not influence the color stability, surface roughness and flexural strength.

Related Dissertations

  1. Oral epithelial cells were infected with Candida albicans after HBD-2 mRNA and protein expression in vitro,R780.2
  2. Research on Processed Surface Roughness of Ram Hole by Fiber Measuring Technology,TG84
  3. The Effect of Different Microwave Polymerizations on Accuracy and Physical Properties of Denture Base Resin,R783.6
  4. The Preparation Stability of Red Color Fome Beet (Bata.vulgaris.L.Var.rubra),TS202.3
  5. Comparison of the Physical and Mechanical Properties Among Four Kinds of Die Stone Casts,TQ177.3
  6. Influence of Surface Physical and Chemical Properties on Heat Transfer Characteristics of Steam Condensation,TK124
  7. Mutation Analysis of ERG11 Gene in Clinical Isolated Candida Albicans Resistance to Azole Agents,R440
  8. Effects of Different Amount of Residual Tooth on the Anti-fracture Property under Lateral Loading in Fiber Post-core System,R783
  9. Genotyping and Antifungal Susceptibility Testing of Candida Albicans from Patients with Atrophic or Erosive Oral Lichen Planus,R781.5
  10. Study on Production and Stability of Fruit & Vegetable Nutrition Wine,TS262
  11. Influence of Surface Roughness on Gold Alloy and Ni-Gr-Ti Alloy on Adhesion Bacteria,R783
  12. Influence Research of the Different Expansion Coefficient Plaster Cast Material on Resin Denture Accuracy and Physical Properties,R783.6
  13. The Resistance of Candida Albicans to Common Antifungal Drugs and Its Expression of CDR1 and CDR2 Gene,R440
  14. Study of Real-time Quantitative PCR on the Early Diagnosis of Deep-seated Candida Infections,R450
  15. The Effect of Polishing Methods on Cobalt-Chromium Castings Accuracy and Physical Properties,R783.6
  16. Study on Erg11gene of Candida Anbicans Azole-resistance Solate from AIDS,R440
  17. Biological Aerated Filter Treatment Polluted River Water,X52
  18. Study of the Relativity between Thedifferent Thickness of Residual Tooth and the Timing of Post-Core Application,R783.3
  19. Comparison of Cleaning Effect of Different Methods on Complete Denture,R783.6
  20. Fluoride on dental cast metal corrosion studies,R783
  21. Comprehensive Evaluation of the Different Basic Periodontal Treatment Techniques,R781.4

CLC: > Medicine, health > Oral Sciences > Oral orthotics > PROSTHETIC
© 2012 www.DissertationTopic.Net  Mobile