Dissertation > Excellent graduate degree dissertation topics show

The Clinical Evaluation of Measuring the Horizontal Sulcus to Sulcus Distance by Ultrasound Biomicroscopy

Author: LiYangChun
Tutor: GuZhaoBin
School: Dalian Medical University
Course: Ophthalmology
Keywords: Horizontal spacing ciliary sulcus (STS) Ultrasound biomicroscopy (UBM) Horizontal position angle distance (ATA) Axial length (AL) Anterior chamber depth (ACD) 3:00 for the 9:00 position cornea and white to white (WTW) Mean corneal curvature (K-value )
CLC: R770.4
Type: Master's thesis
Year: 2011
Downloads: 8
Quote: 0
Read: Download Dissertation

Abstract


Objective: To examine panoramic ultrasound biomicroscopy (ultrasound biomicroscopy, UBM) (KINSCAN) direct measurement of the horizontal spacing ciliary sulcus (sulcus to sulcus, STS) is feasible. STS after the measurement , by comparison to speculate sulcus other common horizontal spacing measurements , test their correlation with the presence STS . Methods: The research center for treatment of 69 patients 120 eyes, with panoramic UBM horizontal spacing measurement sulcus (STS). Pearson correlation analysis and inspection STS pitch angle with the horizontal position (ATA), axial length (AL), measured by the panoramic UBM anterior chamber depth (ACDu), the A -type ultrasonic detector measuring the anterior chamber depth (ACDa), 3:00 for the 9:00 position limbal diameter ( also known as 3:00 for the 9:00 position cornea and white to white , WTW), mean corneal curvature (K value ) whether the correlation was statistically significant, further testing using multiple linear regression analysis its overall relevance. Results: 1 measured in the present study , 120 eyes , STS can be directly measured . STS average (10.19 ± 1.16) mm, the standard deviation is 0.58 , the coefficient of variation (5.75 ± 0.65)%. 2 , the Pearson correlation analysis , ATA, WTW, AL, K value , ACDa, ACDu correlation with STS were statistically significant, p values ??were less than 0.05. Which , AL, ATA has a moderate correlation ︱ r_ ≥ 0.5, respectively, 0.596 and 0.530; WTW, ACDa, ACDu, K value has a weak correlation , 0.3 ≤ ︱ r_ lt; 0.5, respectively 0.432,0.490 , 0.489 and 0.351 . 3, in the multiple linear regression analysis , AL, WTW was confirmed a linear correlation with the STS , the p-value was less than 0.05 , respectively, 0.00001 and 0.049 , statistically significant . ATA, K value , ACDa, ACDu there is no linear correlation with the STS , and its p-value greater than 0.05, respectively 0.085,0.238,0.665,0.132 , not statistically significant. Conclusion: a panorama UBM measurement STS feasible. 2 , the STS can not be measured directly , indirectly through the AL, WTW, ATA to speculate STS.

Related Dissertations

  1. A Prospective Ultrasound Biomicroscopy Evaluation of Changes in Anterior Segment Morphology of Primary Angle Closure after Laser Therapy,R779.63
  2. Clinical Analysis on Suturing Reattachment Operation of Traumatic Ciliary Body Detachment,R779.6
  3. Clinical Study on Nonperforating Trabecular Surgery with Cauterized Autosclera Implantation,R779.6
  4. Comparison between Intraocular Pressureeasured with ICARE Rebound Tonometer and NCT Tonometer,R770.4
  5. Characterization of Human Corneal Epithelial Cell Line and Reconstruction of Corneal Epithelium in Vitro,R770.2
  6. The Comparison of Intraocular Pressure Measured by Icare Rebound Tonometer, Goldmann Applanation Tonometer and PASCAL Dynamic Contour Tonometer in Healthy Subjects,R770.4
  7. Experiment Study of Manganese-Enhanced MRI of Optic Visual Pathway in Vivo,R770.4
  8. Retinal Screening Analysis of 55 High-risk Births,R770.4
  9. Experimental study of the effect and mechanism of amniotic membrane on human conjunctival squamous metaplasia,R770.2
  10. GSH, catalase inhibition induced by TGF-β_2 rabbit lens epithelial cell apoptosis and interstitial Research,R770.2
  11. Experimental Study on Construction of Adenovirus with the Recombinant Kringle 5 Gene and Its Anti-neovascularization,R770.2
  12. An Experimental Study on Morphological Changes Induced by Intravitreal Triamcinolone Acetonide and Its Vehicle in Rabbit Retina,R770.5
  13. Clinical Observation of the Effect of Avastin to the Intraocular Neovascularization,R770.5
  14. Diabetic retinal microcirculation lesion basis and examination methods study was to investigate,R770.4
  15. Chromatest Computer Color Vision Test and Electrophysiology of Vision Test Used in Color Perception Deficiencies,R770.4
  16. The Clinical Utility of Central Corneal Thickness Measured by Pentacam System,R770.4
  17. The Experimental Research on Safety and Intraocular Drug Concentration of 80mg Triamcinolone Acetonide Periocularly Injected,R770.5
  18. Induction of Vitreous Cavity-Associated Immune Deviation(VCAID) and Change of VCAID during Normal Pregnancy,R770.2
  19. UV-induced human lens epithelial cell apoptosis and its suppression,R770.2
  20. Study on The Intra-ocular Bio-compatibility of PSBM,R770.2

CLC: > Medicine, health > Ophthalmology > Eye diagnostics
© 2012 www.DissertationTopic.Net  Mobile