Dissertation > Excellent graduate degree dissertation topics show
Research on MCCB Terminal Heating and on-line Monitor System of Terminal Temperature Rise
Author: ChenYiMin
Tutor: ZhangXiaoQing
School: Beijing Jiaotong University
Course: Electrical Engineering
Keywords: Low-voltage circuit breaker Terminal Blocks Temperature rise Online monitoring Power Line Carrier
CLC: TM561
Type: Master's thesis
Year: 2009
Downloads: 157
Quote: 0
Read: Download Dissertation
Abstract
|
The low-voltage circuit breaker is the most common electrical equipment in the field of low voltage power distribution . The various parameters of the low-voltage circuit breaker online monitoring and remote control of the future direction of the development of the low-voltage circuit breaker . , The temperature rise of the terminals is an important indicator in the various parameters of the low voltage circuit breaker . Terminal blocks bear breaker body with wires connected parts , abnormal temperature rise will not only caused by the mechanical connection of the equipment hidden , and the low-voltage distribution network incidents , but also the formation of the electrical fire hazards . With the miniaturization of the shape of the low-voltage circuit breakers , the size of its unit fever greatly increased. Component temperature rise of terminals become issues that affect low-voltage circuit breaker reliability can not be ignored . This paper around the terminals temperature rise of low-voltage circuit breakers work . Analysis of the low-voltage circuit breaker line monitoring technology and terminal temperature rise of the status quo . LonWorks power line carrier technology - based and designed to develop a low-voltage circuit breakers for low-voltage power line carrier communication terminals online monitoring data collection and communication module , the design points . The host computer monitoring program written in Visual Basic Software and Access software . Of the design of hardware and software online monitoring of the temperature of the low-voltage circuit breaker terminals test platform . This paper analyzes the characteristics of the temperature rise of the low-voltage circuit breaker terminals , thermal network model of the temperature rise of terminals . Influencing factors of the temperature rise of the terminals test data analysis , and the use of the method of least squares fit to the temperature curve , 100A low voltage circuit breaker terminals thermal time constant is obtained , discussed the rapid projected low voltage breaker terminal stable temperature rise of the solution .
|
Related Dissertations
- Real-Time Power-Stealing Monitoring and Arrear Management System,TM73
- Buildings Energy Efficiency Analysis System Based on Thermal Parameters Measurement and On-line Reconstruction,TU111.195
- PLC-based energy billing system,TP311.52
- Calculation on Temperature Field of Permanent Magnet Linear Synchronous Motor,TM341
- Analysis of Generator Rotor Widing Inter-turn Short Circuit Fault Based on Shaft Voltage,TM311
- The Selection of Disturbance Models in Performance Assessment of Control Loops,TP273
- Research and Application of Intelligent Substation,TM76
- Research of On-line Vibration Monitoring System on Stator End Windings of Turbo-generator,TM311
- The Research and Realization of Synchronous Generator On-Line Monitoring System,TM341
- Water-mdeiated Ablation of Hard Biotissue with Pulse Lases,R318.51
- Based on WAMS LFO online monitoring software development,TM712
- Transformer Condition Monitoring Technology and Its Application,TM407
- Gian 10kV substation capacitor failure causes of,TM53
- Study on Failure Diagnosis for Mechanical Characteristics of High-voltage Vacuum Circuit Breaker,TM561.2
- Oil-immersed transformers Insulation Online Monitoring System,TM411
- Design of Optimal Operation Control System for Ground Source Heat Pump Central Air Conditioning,TP273.1
- Power quality monitoring terminal of the hardware implementation,TM764
- Analysis and Design of pollution sources online water quality monitoring system,TP277
- Improved FFT for High Dielectric Loss Tangent Measurement Based on Nine Points’ Polynomial Transform,TM934.32
- Study on Galloping Trajectory Simulation of Transmission Line and Galloping Monitoring System Based on Accelerometer Sensors,TM75
- Study of Transformer On-line Monitoring Based on Vibration,TM407
CLC: > Industrial Technology > Electrotechnical > Electrical > Electrical switches,circuit breakers > Breaker
© 2012 www.DissertationTopic.Net Mobile
|