Dissertation > Excellent graduate degree dissertation topics show

Research on MCCB Terminal Heating and on-line Monitor System of Terminal Temperature Rise

Author: ChenYiMin
Tutor: ZhangXiaoQing
School: Beijing Jiaotong University
Course: Electrical Engineering
Keywords: Low-voltage circuit breaker Terminal Blocks Temperature rise Online monitoring Power Line Carrier
CLC: TM561
Type: Master's thesis
Year: 2009
Downloads: 157
Quote: 0
Read: Download Dissertation

Abstract


The low-voltage circuit breaker is the most common electrical equipment in the field of low voltage power distribution . The various parameters of the low-voltage circuit breaker online monitoring and remote control of the future direction of the development of the low-voltage circuit breaker . , The temperature rise of the terminals is an important indicator in the various parameters of the low voltage circuit breaker . Terminal blocks bear breaker body with wires connected parts , abnormal temperature rise will not only caused by the mechanical connection of the equipment hidden , and the low-voltage distribution network incidents , but also the formation of the electrical fire hazards . With the miniaturization of the shape of the low-voltage circuit breakers , the size of its unit fever greatly increased. Component temperature rise of terminals become issues that affect low-voltage circuit breaker reliability can not be ignored . This paper around the terminals temperature rise of low-voltage circuit breakers work . Analysis of the low-voltage circuit breaker line monitoring technology and terminal temperature rise of the status quo . LonWorks power line carrier technology - based and designed to develop a low-voltage circuit breakers for low-voltage power line carrier communication terminals online monitoring data collection and communication module , the design points . The host computer monitoring program written in Visual Basic Software and Access software . Of the design of hardware and software online monitoring of the temperature of the low-voltage circuit breaker terminals test platform . This paper analyzes the characteristics of the temperature rise of the low-voltage circuit breaker terminals , thermal network model of the temperature rise of terminals . Influencing factors of the temperature rise of the terminals test data analysis , and the use of the method of least squares fit to the temperature curve , 100A low voltage circuit breaker terminals thermal time constant is obtained , discussed the rapid projected low voltage breaker terminal stable temperature rise of the solution .

Related Dissertations

  1. Real-Time Power-Stealing Monitoring and Arrear Management System,TM73
  2. Buildings Energy Efficiency Analysis System Based on Thermal Parameters Measurement and On-line Reconstruction,TU111.195
  3. PLC-based energy billing system,TP311.52
  4. Calculation on Temperature Field of Permanent Magnet Linear Synchronous Motor,TM341
  5. Analysis of Generator Rotor Widing Inter-turn Short Circuit Fault Based on Shaft Voltage,TM311
  6. The Selection of Disturbance Models in Performance Assessment of Control Loops,TP273
  7. Research and Application of Intelligent Substation,TM76
  8. Research of On-line Vibration Monitoring System on Stator End Windings of Turbo-generator,TM311
  9. The Research and Realization of Synchronous Generator On-Line Monitoring System,TM341
  10. Water-mdeiated Ablation of Hard Biotissue with Pulse Lases,R318.51
  11. Based on WAMS LFO online monitoring software development,TM712
  12. Transformer Condition Monitoring Technology and Its Application,TM407
  13. Gian 10kV substation capacitor failure causes of,TM53
  14. Study on Failure Diagnosis for Mechanical Characteristics of High-voltage Vacuum Circuit Breaker,TM561.2
  15. Oil-immersed transformers Insulation Online Monitoring System,TM411
  16. Design of Optimal Operation Control System for Ground Source Heat Pump Central Air Conditioning,TP273.1
  17. Power quality monitoring terminal of the hardware implementation,TM764
  18. Analysis and Design of pollution sources online water quality monitoring system,TP277
  19. Improved FFT for High Dielectric Loss Tangent Measurement Based on Nine Points’ Polynomial Transform,TM934.32
  20. Study on Galloping Trajectory Simulation of Transmission Line and Galloping Monitoring System Based on Accelerometer Sensors,TM75
  21. Study of Transformer On-line Monitoring Based on Vibration,TM407

CLC: > Industrial Technology > Electrotechnical > Electrical > Electrical switches,circuit breakers > Breaker