Dissertation > Excellent graduate degree dissertation topics show
Establishment of On-line Monitoring Method for Water Treatment Agent and Design of the Corresponding Instrument
Author: ZhangZhen
Tutor: YuanDongXing
School: Xiamen University
Course: Environmental Engineering
Keywords: on-line monitoring fluorescence analysis fluorescence tracer dyanmic stimulant
CLC: TQ085.4
Type: Master's thesis
Year: 2009
Downloads: 176
Quote: 4
Read: Download Dissertation
Abstract
|
There are mainly three problems in industrial circulating water systems,namely, scaling,corrosion and microorganism growth.In order to reduce those problems,a lot of different types of water treatment agents have been developed,such as scale inhibitors,corrosion inhibitors and flocculants.Nowadays,although water treatment agents produced at home and abroad can basically control the problems existing in the circulating water,it is still a key point to keep a proper concentration of effective agents in the circulating water system.Therefore,it is very important to determine the concentration of water treatment agents rapidly and accurately.This work was aimed to on-line monitor the water treatment agents.The main experiments and results are as follows:(1) According to the field operation parameters of a clean circulating water system in a selected steel plant,a technical route of the on-line monitoring for water treatment agents had been designed.The water treatment agents and a fluorescence tracer agent was mixed in proportion and put into circulating water system,and the fluorescence tracer was monitored on-line,and finally the concentration of the water treatment agents was calculated on the basis of fluorescence tracer concentration.(2) Carboxysulpho naphthalimide(CSN) was chosen as the fluorescence tracer agent.Its toxicity on zebra fish was tested.The result showed that there was no visible effect on the fish when CSN concentration was as high as 500 ng/mL under the explosure time of 96 h.Based on the water quality indexes of the circulating cooling water system in the steel plant,the effects of the temperature,pH,biocides and other parameters on the CSN fluorescence intensity were investigated.The results showed that CSN was stable to most of water conditions,but the high level of biocides could reduce the CSN fluorescence intensity.It was concluded that CSN could be used as the fluorescence tracer agent in circulating cooling water system.(3) A special on-line fluorescence monitoring system had been designed based on the modern analytical instrumental design ideas,such as integration, customization and miniaturization.Components of the designed fluorometer included the following parts:power source module,excitation source module, flow cell,optical signal filtering and focusing device,detector,data analysis and processing device,result displayer.(4) The stability of the on-line fluorescence monitoring system,and some performance parameters of the monitoring method,such as precision and detection limit,had been studied.The results showed that the performances of the instrument met the design requirements.(5) This on-line fluorescence monitoring method was an indirect method to determine water treatment agent,the feasibility of the method had been preliminarily proven with a dyanmic simulant device.It was found that there was a good correlation between the concentration of fluorescence tracer and total phosphates,if the concentration multiple of the circulating cooling water was less than 2.5.Therefore,using the mixture of CSN and water treatment agents in a proper proportion,together with the on-line fluorescence monitoring system,the on-line indirectly determination of the concentration of water treatment agents in low concentration multiple of clean circulating water system in steel plant could be realized.
|
Related Dissertations
- Study on Transmission Lines On-line Monitoring,TM76
- Fluorimetric Analysis of Methyl Salicylate, Daidzin and Daidzein in Chinese Herbal Medicine,O657.31
- The Applicability of Data Mining Technology for Environmental Protection Management System,TP311.13
- Transmission line icing icing mitigation technology research and online monitoring system design and implementation,TM755
- Development and Application of On-line Monitoring of High-Voltage Switchgear Cabinet,TM591
- Application Analysis and Risk Assessment Methods of Dynamic Line Rating System for Overhead Transmission Line,TM76
- Study of the Detection System Used for the Chlorophyll in Seawater,P716
- Research on Insulation Damp Fault Features and Warning Methods of Capacitance Equipments,TM855
- Design of On-line Partial Discharge Monitoring System for Transformer,TM855
- Fluorimetric Analysis of Active Components of Chinese Medicine Dinggongteng and Jinyinhua,R284.1
- Analysis of Three-dimensional Fluorescence Spectra of Chinese Medicine Baihuaqianhu and Zihuaqianhu,R284.1
- Eu ~ (3) the fluorescent copolymer and polymer matrix composites Preparation and Properties of,O631.3
- Research on the Modeling of the Online Over-voltage Monitoring System and the Numerical Inversion Calculation Methods,TM866
- Research on On-line Monitoring Technique for Key Parameters of Vacuum Circuit Breaker with Permanent Magnetic Actuator,TM561.2
- Study on the Insulation On-line Monitoring System of HV Motor,TM306
- The Design of On-line Monitoring System of Transformer Fault,TM407
- Study on System for Ultrasonic Detection of Generator Stator Winding Partial Discharge,TM307
- Study on the Online Monitoring of Generator Stator Winding Partial Discharge Based on the Ultrasonic Method,TM307
- Study on Monitoring System of Transmission Lines Galloping Based on Wireless Sensor Network,TP212.9;TN929.5
- Development of Intelligent Online Monitoring System for Asynchronous Motors Based on LabVIEW,TP274
- The Rapid Toxicity Testing Based on Luciferase and the Study of on-line Toxicity Biosensor,X85
CLC: > Industrial Technology > Chemical Industry > General issues > Chemical plant > Industrial water,water treatment > Water treatment