The Study on the Lightning Protection Performance of Double Circuit for 220kV Transmission Line
Author: YanXiPing
Tutor: LiJingLu
School: Changsha University of Science and Technology
Course: High Voltage and Insulation Technology
Keywords: double-circuit transmission line back striking shielding failure lightning protection performance aimability transformation measure
CLC: TM862
Type: Master's thesis
Year: 2009
Downloads: 486
Quote: 7
Read: Download Dissertation
Abstract
|
In recent years, with our country’s rapid economic development, electric power load demand is getting increased day by day. Using the same tower double-circuit extra-high voltage(EHV) transmission line such as 220kV, 500kV or higher voltage for long distance power transmission has become a necessity. These programs can greatly reduce transmission line corridors. However, the breakdown accident often occurred by lightning strike. So it has important significance and applied value for profound analysis of lightning protection performance in accordance with the various mechanism of breakdown accidents caused by lightning strike.Based on the wide collection and summarizing of running conditions of 220kV transmission lines in Chizhou, Anhui, the current lightning protection situation is analyzed. Choosing 220kV chiguan #2886 line、guanju #2850 line as research objects, systematic study is made on the lightning protection performance of 220kV double-circuit transmission line by ATP-EMTP and strack distrance method. The main problems of Chizhou 220kV double-circuit transmission line are summarized and modification measures based on the region topography of Chizhou are suggested as following:1. Reverse phase arrangement can effectively decrease the simultaneously rate of flashover should.2. Multi-pole-reclosing can effectively limit the harm of power system from simultaneity flashover should.3. It is still one of the most effective method to reduce the rate of lightning back striking on double-circuit transmission line by decreasing grounding resistance of tower.4. The installation of anti-flashover should lateral-lightning rod is one of the effective method of anti-around hit.5. The installation of line arrester is a very good remedy measure in few regions where is big across, has high rate resistance of soil which is difficult to reduce and furthermore, the effect of shielding operation is very unsatisfactory by existing measure.6. Reducing the shielding angle of lightning shield line can reduce the occurrence of shielding failure lightning accident. 7. Erecting coupling-groundwire along the whole line can do inhibitory effect to shielding failure and back striking.8. Reinforced insulation is the most effective and economical method of decreasing the rate of lightning back striking.9. Taking feasible method to decrease the galloping of ground wire and the moving speed of thundercloud can effectively reduce accidents caused by lightning.10. For new lines, methods should be taken such as adding a lightning shield line and optimizing design of the tower head to improve the level of resistance-lightning of 220kV transmission line.The results of this paper will propose practical reference value and important theory basis for the design and operation work of lightning-prevention of 220kV double-circuit transmission line, then it can be extended rectifying and reforming of lightning-prevention in other areas, so it has important reference meaning. The thesis has practical application value and direct economical and social benefit also.
|
Related Dissertations
- Study on Lightning Protection Performance of Quadruple-circuit Transmission Line with Dual Voltage 1000kV/500kV on the Same Tower,TM75
- Research on Lightning Protection Measures for 35kV Power System of Dexing Copper Mine,TM862
- Research on Construction Technology for Exchanging Blackout Wire in the Double-Circuit 220KV Overhead Transmission Lines,TM752
- Study on the Lightning Protection Performance of Shielding Failure for Inner Mongolia 500kV Transmission Line in Mountainous Area,TM862
- 1000kV UHV AC transmission line lightning protection research,TM723
- Analysis of Integrated Lightning Protection on High Voltage Transmission Line,TM862
- Visualization Study on the Lightning Strike Risk of HV Transmission Line Based on the Single Band Partition Methods,TM862
- Research on Power Grids Traveling Wave Fault Location Method Based on Graph Theory,TM755
- Study on Lightning Protection Performance of Transmission Lines with Corona,TM862
- Lightning Protection Study on 750kV Transmission Line Built in Qin Ling Mountainous Region,TM862
- The same tower 500KV line of lightning protection performance,TM862
- Study on the Lightning Protection Performance of Transmission Line,TM862
- Study on the Simulation Model of Shielding Failure and the Lightning Protection Performance of Double Circuit for AC Transmission Line,TM862
- Study on Calculation of Shielding Failure Flashover Rate for Transmission Line Based on Electric Geometry Model,TM862
- The Differentiation of Lightning Shielding Failure and Back Flashover on High-Voltage Transmission Line,TM863
- The Fault Protection Technique of Transmission Lines Double-circuits on Same Tower for High Voltage Grid,TM755
- Investigation of Typical Lightning Stroke Obstacles on 500kV A.C. and D.C. Transmission Lines,TM862
- Study on Lightning Protection Performance of High Voltage Transmission Line in Mountainous Area and Counter Measures,TM862
- Lightning Protection and Insulation Coordination of Mixed-voltage Quadruple-circuit Transmission Line on the Same Tower,TM862
- Research on the Evaluation Method on Lightning Protection Performance of UHV DC Transmission Lines,TM862
CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage protection devices
© 2012 www.DissertationTopic.Net Mobile
|