Dissertation > Excellent graduate degree dissertation topics show

Research on Corrosion Diagnosis of Substation Grounding Grid and Its Influence Factors

Author: XiaoLeiShi
Tutor: LiuYuGen
School: Chongqing University
Course: Electrical Engineering
Keywords: grounding grid corrosion diagnosis substation engineering practicability
CLC: TM862
Type: Master's thesis
Year: 2011
Downloads: 138
Quote: 0
Read: Download Dissertation

Abstract


The security and reliability of power system is affected by the safe operation of substation, and the complete and reliability of grounding grid is the security of substation. The conductors which constitute the grounding grid are buried under ground, the situation that makes poor electrical connection in conductors is caused by bad weld and the effect of electric power of earth short-circuit current, especially severe soil corrosion by several years. Corrosion of grounding conductors and broken grounding grids will cause disqualification of grounding resistance, step voltage, and touch voltage in substations. So, testing the break point and corrosion situation in grounding grid, identifying and excluding the hidden fault, and preventing the harm from poor grounding is particularly important.Currently, experts have proposed some principle and mathematical model about fault diagnosis of grounding grid, but lacking of engineering practicability. This thesis presents a comprehensive optimization diagnosis method that applies circuit theory, together with some principles for selecting the most sensitive and effective ports for conducting minimum measurements to detect the suspect faults. This method has proved to be engineering practicability by field experiment in substations. But in order to improve the accuracy of diagnosis result, some influence factors existing only in filed test should be taken in account, such as inaccurate grounding grid drawings, offsetting of grounding down lines, and some interference.This thesis mainly studies content for theory and method of erosion diagnosis of grounding grid.1 For steel frame in substation is also connected with grounding grid, and forming a resistance branch of grounding grid. Assuming frame conductor connected at edge and internal of grounding grid, a total of 8 cases, simulating and computing the diagnosis results compared with ignoring the influence of frame conductor. Meanwhile, conventional frame resistance in 110kV, 220kV, 500kV substation is calculated. These resistance data will guide the deeper simulation of frame branch influence in grounding grid corrosion diagnosis.2 Focus on the problem of grounding down lines’deviation existing only in field test, the deviation is set to four levels. Through the simulation and experiment, we draw the conclusion that when the deviation increases, the increases multiple of eroded branch resistance reduces, while the quantity of pseudo-fault branch and its increase multiple of resistance increase.3 Taking substation cable channel conductor which also connected with grounding grid and form electrical circuit into grounding grid erosion diagnosis, by simulating and calculating, the diagnosis result will be more accurate if the cable channel conductors add into grounding grid structure.4 Real world field test of corrosion diagnosis of grounding grid is taking at two substations. Results demonstrate that it is a relatively simple, effective and practical approach for grounding grid corrosion diagnosis.

Related Dissertations

  1. Substation Integrated Early Warning System and Application,TM76
  2. Oilfield Grid Control Station System Design and Research,TM734
  3. 200kV Yanzhan Substation Transform the Problem of Computer Protection,TM774
  4. Design of Supervisory and Control System for Xiao Piao 66kV Substation,TM769
  5. Study on Heat Load Characteristics and Heat Dissipation of Prefabricated Substation,TM63
  6. Research of Wucun Substation Digitization Reconstruction Scheme and Post-project Evaluation,TM63
  7. The Analysis on the Feasibility of Intelligent Substation in Hengqin Island,TM76
  8. Based on IEC61850 the Sanxiang Substation Engineering Application,TM76
  9. Substation intelligent monitoring system development,TP311.52
  10. The Research on the Practical Application of Fiber-optical Protection for Transmission Lines,TM773
  11. Research on Monitoring System of Remote Video and Environment in Intelligent Substation,TM76
  12. Schedule Management Research on Power Transmission and Transormation Project in Rizhao,F426.61
  13. The Study of Construction Quality Risk Management of 500kV Kuwan Substation Project,F426.61
  14. Research on Renovation of Monitoring System in 500kV LuoDong Substation,TM63
  15. Research on Lightning Protection against Intruding Wave of Booster Station in Lighting Intensified Area,TM862
  16. Study of Subway Substation Maintenance Team’s Standardization Building,F572.88
  17. Yunlong County immigrant supporting projects 35kV substation back the old state system design and implementation,TM63;TM76
  18. The Application Study of Misoperation Locking Device in Substation,TM774
  19. Research of Substation Integrated Automation Monitoring System,TM63
  20. Substation equipment connector Temperature Management System Design and Development,TP311.52
  21. Study on the Green Substation Construction of Zhaoqing Power Grid,TM63

CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage protection devices
© 2012 www.DissertationTopic.Net  Mobile