Dissertation > Excellent graduate degree dissertation topics show
The Accuracy of Guided Template in Implant Placement of Computer-based Guded Surgery: a Pilot Study
Author: YuDan
Tutor: WangHuiMing
School: Zhejiang University
Course: Oral and Maxillofacial Surgery
Keywords: Computer - aided surgical template Planting positioning Planting drill and guide sleeve gap Maximum tilt angle Implant position
CLC: R783.6
Type: Master's thesis
Year: 2011
Downloads: 51
Quote: 0
Read: Download Dissertation
Abstract
|
Objective: Analysis planting drill with guide thimbles gap in extreme cases the implantation position the influence of the maximum angular deviation , the clear actual osteotomy preparation the steps of generating the maximum angle of deviation and the cumulative maximum angular deviation . Methods : planting drill and guide sleeve into a maximum deflection angle , Simplant / Classic SurgiGuides surgical template in turn guide the planting drill (02.2mm, 02.8mm, 03.5mm) planting positioning on some teeth missing plastic model . Measurement template guided planting fossa the actual implantable angle and the ideal angle deviation from the analysis of the relationship between the maximum angle of deviation compare the template reaming and progressively reaming . Results : different methods , each template (separately or stepwise ) to guide the positioning generating maximum angular deviation there are theoretical values ??significant difference , the maximum angular deviation of Template A (5.15 ° ± 1.27 °; 4.32 ° ± 1.23 °) was significantly higher than template B (1.42 ° ± 0.78 ° ; 1.08 ° ± 0.33 ° ) , C (3.00 ° ± 0.64 °; 2.35 ° ± 0.81 ) P value less than 0.05 . The template C significantly greater than the template B ( p = 0.01988 ; p ( stepwise ) = 0.02667 ) . Prepared by different methods of planting nest maximum angle of deviation , no significant difference . Prepared by two methods under the template A , C of the actual implantation angle deviation were significantly higher than the theoretical value ( 1.798 ° , 1.581 ° ) . Conclusion: computer - aided surgical template to guide Pioneer Pioneer drilling template \In extreme cases , Pioneer template to guide the actual maximum angle deviation is greater than the theoretical value , require the surgery paid special attention to the first positioning accuracy . Planting drill and the choice of the the guide thimbles best gap size , as well as step by step reaming each step in the preparation of cumulative maximum deviation respectively reaming whether there were significant differences between the research will be to further clarify . Intraoperative template retention stability is a key prerequisite for precise transfer .
|
Related Dissertations
- A Study of the Relationship between Ultrasound Images of Masicatory Muscle and Caraniofical Morphlogy of Young Males with Nomal Occlusion,R783.5
- Experiments Study of BIO-OSS on PRP Composite Repairing Bone Defect around Metal Nail of Pure Titanium,R783.6
- Root Resorption of Upper Centre Incisor with Compensation in Skeletal Class Ⅱ and Ⅲ Malocclusions,R783.5
- Several Low Flat Mandibular Alveolar Ridge to Improve Denture Retention Methods of Clinical Experience,R783.6
- The Dual-phase Treatment of Skeletal Class Ⅲ Malocclusion.,R783.5
- The Combined Treatment of Complex Adult Angleclass Ⅱ Division 1,R783.5
- To Observe the Effect of Different Dental Filling Technologies on the Microleakage under Confocal Laser Scanning Microscope,R783
- The Clinical Evaluation on Gingival Aesthetics of Immediate Implant and Immediate Prosthesis of Maxillary Anterior.,R783.6
- Comparison of Differences on Osseointegration among Immediate Implant, Delayed Implant after Bone Graft and Delayed Implant at Different Time,R783.6
- Evaluation of between the Occlusal Force and the Tissues Health Surrounding Implant of ITI Implants with Zirconia All-ceramic Crown,R783
- The Experimental Study on Effect of Different Low-power Laser Irradiation on Osseointegration of Dental Implants,R783.6
- The Influence on the Dimensional Stability and Elastic Deformation Caused by Two Types of Disinfectant Solution to Different Impression Material,R783
- Expression of BMP-1 in Periodontal Tissues during Orthodontic Tooth Movement in an Animal Experimental Study,R783.5
- Micro-implant Anchorage in Adults with Type of Open Bite Treatment,R783.5
- Orthodontic Treatment in Adults with Class Ⅲ Malocclusion Combined Low Angle by Extraction Four Premolars,R783.5
- Extraction Orthodontic Treatment of the Low Angle Deep Overbite Malocclusion,R783.5
- Influence of Various PH and the Treating Time on Mechanical Property and Surface Structure of Ni-ti Orthodontic Wire,R783.5
- A Clinical Study of Simultaneous Implant Placements after Sinus Floor Elevation in Maxillae with Less Than 5mm of Residual Bone Height,R783.6
- An Analysis of Bacterium Adhesions on the Surface of Restorative Materials of RPDs in Vitro,R783.6
- Different Bottom Structure of Dental Brackets Affect the Adhesiveness-Three Dimensional Finite-element Analysis,R783.5
- The Reference Indexes of Clinical Diagnosis Preparation with the Skeletal ClassⅡ Malocclusion in Prepubertal Growth Periods in Dalian,R783.5
CLC: > Medicine, health > Oral Sciences > Oral orthotics > PROSTHETIC