Dissertation > Excellent graduate degree dissertation topics show
Study on Thermal Comfort, IAQ in Shanghai Suburb and the Testing System Based on Labview
Author: LiuZuo
Tutor: ZouZuo
School: Donghua University
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: Thermal comfort Adaptive model Comfortable temperature CO2 concentration Labview
CLC: TU831
Type: Master's thesis
Year: 2010
Downloads: 86
Quote: 0
Read: Download Dissertation
Abstract
|
The article first Fanger 's thermal comfort model , using Labview developed 8-channel data acquisition and thermal comfort test system . Test system temperature, wind speed , relative humidity , once the CO 2 < / sub> concentration parameters for real-time data acquisition , sampling frequency up to 10HZ PMV, PPD, water vapor content , and real-time processing data , the dew point secondary parameters such as temperature . Through a long period of testing , the system stable and reliable operation . Then , the use of the test system , the selected test room , testing room indoor thermal comfort . The study found the winter indoor air-conditioned room air temperature variations is much higher than the room in summer , winter, air-conditioned room indoor temperature trend is consistent with the outdoor temperature ; the summer indoor relative humidity about winter times , winter relative humidity less than 40 % ; indoor air flow rate is less than 0.2m / s, about 0.1m / s , the basic thermal sensation ; the indoor CO 2 concentrations rising day's work time , only at lunch time to stabilize for some time. The indoor CO 2 sub > concentration of human activities related to the increase of the conversation will instantly improve the indoor CO 2 sub > concentration . Finally, the questionnaire based Dedear the adaptive model to study the indoor thermal comfort of the suburbs of Shanghai School . The study found that the school office good thermal comfort room personnel for more than 80% of the thermal environment satisfaction . Satisfaction higher winter no air conditioning room air-conditioned room 10% , to the satisfaction of the air-conditioned room in the summer no air conditioning room 10% higher ; school location , comfortable temperature of 22.66 ° C in winter and summer comfort temperature of 26.09 ° C ; winter when indoor CO 2 sub > concentrations higher than 800PPM , give people a sultry feeling ; summer CO 2 sub > concentrations no significant effect on thermal sensation .
|
Related Dissertations
- Image Analysis System of Metal Transfer of Gas Metal Arc Welding,TG444
- Research on Nozzle Plume Temperature Distribution Measurement System,V434
- The Electrostatic Dust Removal System Based on Microcontroller and LabVIEW,X701.2
- Effects of CO2 Concentration and Nitrogen Application on Grain Yield, Quality Formation and Their Physiology Mechanism in Winter Wheat,S512.1
- Oil -in-water type emulsified oil water hammer harmonic LabVIEW Simulation and Experimental Research demulsification,X703
- LabVIEW-based virtual oscilloscope design and remote control,TM935.3
- Axial fan blade vibration non-contact measurement,TD441.2
- Exploration and Analysis of Electronic Detection of Raw Silk’s Flatness,TS147
- Control System Research for a Nano-Material Mixer,TP273.5
- Simulation System for Aluminum Foil Cold Mill and Research of Tension Control,TG334.9
- Research and Application of Remote Virtual Instrument Experimental Teaching System Based on LabVIEW,TP391.6
- Multi-channel Real-time Online Monitoring System for Polymerizers,TP274
- Research on Thin-Film Hysteresis Loop Measurement System Based on Extraordinary Hall Effect,O484.43
- The Research and Design of a Fire Detection System Based on Combustion Audio Recognition,X924.4
- Research of Control Strategy Based on the Electro-hydraulic Proportional Position Control System,TH137.52
- The Simulation Research of Non-steady Thermal Comfort of Railway Station,TU831
- Development and Experimental Study about Virtual Instruments of Vibration Test and Analysis System and Combustion Analyzer,TK407
- The Thermal Comfort Research of Campus Architecture in Hot Summer and Wram Winter Zone,TU111
- Based on closed-loop control design electrical nerve stimulation,R742.1
- Adaptability and \,TU831
- Large span structural health monitoring system,TU399
CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning
© 2012 www.DissertationTopic.Net Mobile
|