Dissertation > Excellent graduate degree dissertation topics show
Fluorescence Optical Fiber Detection System for Pesticide Residue Based on Ccd
Author: XuHuiJuan
Tutor: WangYuTian
School: Yanshan University
Course: Measuring Technology and Instruments
Keywords: pesticide residue fluorescence analysis optical fiber sensing linear array CCD A/D data acquisition
CLC: S481.8
Type: Master's thesis
Year: 2010
Downloads: 92
Quote: 0
Read: Download Dissertation
Abstract
|
As important input material in agricultural production, pesticides play an irreplaceable role in promoting agricultural development, satisfying people’s demand for agricultural products.But the pesticide itself is a class of toxic chemical substance, the pollution due to irrational use of pesticides has done serious damage to human healthy and ecological environment. Therefore, we must strengthen the detection of pesticide residue and their metabolites.There are some disadvantages in traditional analysis methods for pesticide residues, such as complicated sample pre-processing and consuming more reagents. Whereas fluorescence analysis method has an advantage of high sensitivity, strong selectivity and less reagent in the detection of concentration and composition analysis, it shows superiority especially in the detection of pesticide residues. This paper intends to develop a fluorescence optical fiber measurement system which is used in the analysis of pesticide residue, combining the technology of fluorescence spectrum detection and optical fiber sensing, to achieve the direct detection rapidly.Starting with the basic principle of fluorescence analysis method, the relationships between molecular structure of some common pesticides (benzoylurea and carbamate) and their fluorescent characteristics are researched, as well as the excitation spectrums and the fluorescence spectrums of these pesticides are studied through experiments, what’s more, their optimal excitation wavelength and fluorescence spectral range are choosen.According to the fluorescent characteristics of pesticides, a fluorescence optical fiber measurement system based Charge-Coupled-Device for detecting pesticide residue is designed. In this system, a short-arc pulsed xenon lamp is choosen as the excitation light source, several interference filters are equipped to meet the need of different pesticides for selecting excitation light; a Y-type optical fiber bundles and spherical optical fiber probe are used for collection and transmission of the excitation light and fluorescence signal; a linear array CCD (RL2048DKQ) with high speed and low power is choosen as photoelectric detector, the corresponding filter and amplifying circuits are also designed; AD16-2K high-speed data acquisition card is accepted to achieve collection and conversion of the signal; the computer software for further processing of the data is designed moreover.The work curves of these pestcides have been determined by the new system, as well as some performance indexes such as accuracy, precision and so on. By comparing the experimental results of this system with those of other standard methods, the rationality and feasibility of the detection method are validated.
|
Related Dissertations
- Design and Development of Application Programme for Fault Analyzer Based on Wince Platform,TP311.52
- Research on the Aiming Signal Processing of the Optical Probe Measurement System,TH74
- Research on Synchronous Acquisition and Processing System Detecting Defocus Signal Based on DSP,TH741
- Study of Automobile Ignition Coil Testing System Based on Standard LAH032.905,U472.9
- Design of High-Speed Data Acqusition Board Based on Signal Integrity Analysis,TP274.2
- Development of 3-Dimensional Scanning Probe Data Acquisition System Based on DSP,TP274.2
- Development of Inductance Sensor Data Acquisition System Based on FPGA,TP274.2
- The Principle Research and Implement of the Acoustic Keyboard for Computer,TP334.23
- Research on the Down-hole Data Sampling and Transmission Method,TE938
- Research of DSP-based Real-time Demodulation Method of One-frequency Laser Interferometer,TN911.3
- Soccer Data Acquisition System,TP212.9;TP274.2
- F enterprises with RFID data capture products to improve i Research and Application,TP274.2
- Design and Implementation of Hydrological Information Automatic Monitoring System,P335
- Cortex-M3 -based real-time data acquisition system μC/OS- Ⅱ and CAN bus,TP274.2
- Study on Network Technology of Wireless Bridge Monitoring System Based on MOAP,TP274
- Research of Ultrasonic Testing System Based on ARM Controller,TP274.53
- The Research of Integratione about Electric Energy Data Acquisition,F426.61
- Research and Development of HART Field Diagnostic Monitor,TP277
- Research on Distributed Fountain Codes,TN911.2
- Personnel Training and the State Data Network Platform Needs Analysis and User Permissions,TP311.52
- Design and Implementation of High Speed Data Acquisition System for Radar Altimeter Echo Wave,TP274.2
CLC: > Agricultural Sciences > Plant Protection > Pesticide ( chemical control ) > Plant chemical protection theory > Pesticide residues
© 2012 www.DissertationTopic.Net Mobile
|