Dissertation > Excellent graduate degree dissertation topics show
Harmonic Study of Different Types of Electric Vehicle Chargers
Author: LiNa
Tutor: HuangMei
School: Beijing Jiaotong University
Course: Electrical Engineering
Keywords: Harmonic Analysis Charger model Uncontrolled rectification charger 12-pulse rectification charger Pulse-Width Modulation rectification charger PSACD
CLC: TM711
Type: Master's thesis
Year: 2010
Downloads: 736
Quote: 16
Read: Download Dissertation
Abstract
|
Face to the financial crisis,high international oil prices and increasingly severe pressure on energy conservation,electric vehicles have become the new direction of the vehicles.Electric Vehicle charging station is a very important part of facility in charging station.lt must fit up numbers of charging station to meet the normal traffic demand and increase charge rate of battery.As a power electronic equipment, EV chargers will pollute the power grids. The choice of different types of charger and the choice of power supply of charging station will affect the economic factor.Therefore, it is necessary to analyze the harmonics, power factor, power consumption, and power supply of charging station.Around the "Research on Charger and Charging Station Models ",using the PSCAD/EMTDC,this paper modelled the uncontrolled rectification charger,12-pulse rectification charger and PWM rectification charger.Issues are parts of the preliminary design work before stations construction.Mainly include the following parts:Modeling the three kinds of chargers. Studying the harmonics,PF, and efficiency.Providing modeling of the charging stations consist of multiple chargers,including input chargers simultaneously or not, and analyzes the harmonics.The DC power supply and AC power supply modes are Studied. Rectifiers and lines losses are compared.The results show that uncontrolled rectification charger produce lots of harmonices,PF equals 0.84.12-pulse rectification charger could decrease the harmonics well,PF equals 0.86,the PWM rectification charger also contains little harmonics while lower efficiency,PF equals 0.986.When multiple chargers works, the 5th harmonic current exceed the limits for the 5 of uncontrolled rectification chargers. The 11th harmonic current exceed the limits for the 19 of 12-pulse chargers.but 20 of PWM chargers works safe under 20.The DC power supply is better than the AC power supply. Under DC bus power supply of the charging station, when the DC power lines longer than 500 meters, the loss of PWM rectifier charger is most minimum, the loss of using 12-pulse rectifier charger is the lowest when the line length from 0 to 500 meters.Research method and the simulation model applicable to other problems of the simulation of charging stations.
|
Related Dissertations
- Design of a Smart Meter with Harmonic Analysis Based on the STM32,TM933.4
- The Application and Research of Neural Network in Power System Harmonics Analysis,TM711
- Improved FFT for High Dielectric Loss Tangent Measurement Based on Nine Points’ Polynomial Transform,TM934.32
- Analysis of the Harmonics of Medium and High Voltage Converters,TN773
- Investigation into the Method of Wind-induced Buffeting Calculation of High-rise Structure,TU973.2
- Research on the Analysis of Power System Harmonics,TM711
- Simulation Research on High-power Arc Heater System,TM924.2
- The Research on the Vibration Property of Slab Tracks with Different Rubber Vibration Isolation Bearings,U213.2
- A Study of the Influence of Active Power Filter on Load,TN713.8
- DSP-based portable low pressure fault recorder study,TM76
- Involutes Direct Planetary Gear Finite Element Analysis Based on ANSYS,TH132.425
- Research on Finite Element and Acoustic Radiation Analysis of Ice’s Injector Vibration,U464.172
- Research and Design of Electric Harmonic Measurement System Based on DSP & CPLD,TM935
- Design and Research of the Electric Power Quality Monitoring System,TM933.4
- Based on neural network algorithm Power System Harmonic Analysis and Research,TM711
- The Development of the Distribution Transformer Remote Monitoring Terminal Based on GPRS,TM421
- Modeling and Harmonic Analysis of the Power Supply System for Electric Arc Furnace,TM924.4
- Study of Elimination and Analysis Device on Power Harmonic,TM711
- The Study of Control Technology about the Two-way Flume for Tidal Simulation,P731.23
- Design of the Metal Oxide Arrester Tester,TM862
CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Theory and Analysis > Network analysis,power system analysis
© 2012 www.DissertationTopic.Net Mobile
|