Dissertation > Excellent graduate degree dissertation topics show
The Studying of in Door Air Qualiquty Controlling Equipment of Toll Gate
Author: ShiGuangXing
Tutor: YangHua
School: Hebei University of Technology
Course: Heating, Gas Supply , Ventilation and Air Conditioning
Keywords: Personal ventilation Tollbooth Indoor air quality Device Controlling
CLC: X51
Type: Master's thesis
Year: 2007
Downloads: 67
Quote: 0
Read: Download Dissertation
Abstract
|
With the developing of the economy, the number of car in our country is becoming more and more. Therefore, automobile off-gas has a lot of negative effect on the environment. The environment near the tollbooth becomes more serious. The health of the staff in the tollbooth is seriously endangered. To improve air qualityćestablishing comfort and health environment indoor to improving the work efficiency,we excogitate the indoor air quality controlling equipment of tollbooth, with it, at the same time, we can save energy in using and control air quality in tollbooth.In this paper, we have successful excogitated the device, which on the base that we have not only analyzed the pollution around of the tollbooth, but also know about the rule of distributing and diffusing of the pollution. Besides that personal ventilation technology have used in the equipment, with which fresh air can be sent to the tollbooth. During the action, not only the temperature of the air, but also the amount of fresh air and the angle of sending it can be adjusted freely. We have studied the equipment farther more, such as the testing that whether the accumulator is reasonable for the water in it and parameter of the fresh air is according with design etc. With the data of test, we can give a conclusion that the equipment achieved the aim improving the indoor air quality completely. We set the equipment in the tollbooth testing the effect result, from this we can give a conclusion that the equipment can not transporting fresh air setting up comfortable environment according with user and also keeping the tollbooth in the state which the air pressure in the tollbooth is a little higher than it out of tollbooth. In this state, the pollution out of the tollbooth can be prevented from entering from the window.The results show that the indoor air quality controlling device in the highway tollbooth can satisfy the design requirements on the temperature control, humidity control, the volume of fresh air control, the comfort of air supply and so on. It can effectively control the indoor air quality and improve the working environment of the staff.
|
Related Dissertations
- Study on the Locomotive Dynamic Supervision System,U284.48
- Research on Temprature Controling Technology of Laser Diode with Thermoelectric Cooler,TN248.4
- Signal Acquisition and Processing Platform Design and Implementation of Trawl Sonar System,S951.2
- Studies on Shoot Treating and Top Grafting Technique for Replacing Cultivar of Pear Tree,S661.2
- Location Assisted Wi-Fi Discovery on Mobile Devices for Energy Saving,TN929.53
- Multi-dimensional charge transport group modify iridium complex design, synthesis and optical properties,O627.8
- Study on the Equity Merger Reform,equity Structure and Cash Dividend Policy of State-owned Listed Company,F276.6
- Study on Properties of Compound Dynamic Damper,TB535.1
- The Research on Distributed Self-Organized Network Based Wide Area Backup Protection,TM774
- Metrological Standard Device of Heavy Direct Current,TM835.2
- Design and Implementation of the NMS park,TP311.52
- MIPS-based wireless communications device driver implementation technology,TP368.1
- Design temperature alarm device using PTCR,TP277
- Recloser based distribution automation system optimization design and research,TM76
- With a small current grounding fault line selection function distribution lines monitoring device design and research,TM862
- XML-based device description communications software development under Linux,TP311.52
- Linux-based distributed switch device virtualization technology research,TP393.05
- Based on infrared thermal image of overhead transmission line fault detection software development,TM755
- Research on Attitude Determination and Magnetic Control for Small Satellites,V448.2
- The Biocompatibility of a Sample of an IUD for the Treatment of IUAs,R318.08
- The RBF-ARX Model-based Nonlinear System Modeling and Predictive Control to Magnetic Levitation System,TP13
CLC: > Environmental science, safety science > Environmental pollution and its prevention > Atmospheric pollution and its control
© 2012 www.DissertationTopic.Net Mobile
|