Abstract
|
DGA technology is an important means of routine monitoring of oil-filled electrical equipment . In this paper, on the basis of the main advantages and disadvantages of the Summary of the current transformer DGA technology to analyze gas photoacoustic spectroscopy detection technique is applied to the advantage of the transformer DGA system and describes the historical background of the photo-acoustic spectroscopy , development status , and Photoacoustic spectroscopy characteristics . Start from the theory of molecular structure and molecular spectroscopy , this paper discusses the detection principle of photoacoustic spectroscopy gas concentrations , including the absorption of light , source of thermal power density generated photoacoustic signal excited . The correspondence relationship of the relationship of the photoacoustic signal and the light intensity, the concentration of gas molecules , and the derivation of the corresponding relationship of the gas concentration with the microphone output electrical signal , applied to the detection method of the gas concentration of Photoascoustics transformer DGA system provides a theoretical basis . Gas concentration detection based on photoacoustic spectroscopy theory , this paper establishes a theoretical model of the transformer DGA system . The analysis of the infrared absorption lines of the six fault gases , the detection wavelength was chosen to avoid interference in the fault gas spectral lines cross , system light source the work wavelength range ; contrast nonresonant photoacoustic cell resonance light the sound of the advantages and disadvantages of the pool based on the design of a small one for non - resonant transformer DGA system volume photoacoustic cell . In this paper, the research on the theory of weak signal detection and noise suppression methods using cross-correlation detection technology designed phase-locked amplifier circuit to replace the lock-in amplifier instrument microphone output signal detection and processing . The design of the circuit using analog multiplier to achieve the function of the phase-sensitive detector , and by the active integrator circuit and the low pass filter and to reduce fluctuations in the output signal , the simulation results show that the circuit can achieve a higher signal - to - noise ratio . Finally, the design system of the experiment of the gas concentration is detected and verified by experimental data the design of the system part of the feasibility, and fitting of the response curve of the detection system .
|
Related Dissertations
- Liquid crystal tunable filter spectral transmittance Test System,TN713
- Research on Measurement System of Photoacoustic Spectrum Based on LabVIEW,O433.1
- DGA -line device automation control and signal processing algorithms,TP273
- The Study of Near-infrared Photoacoustic Spectroscopy and Trace Detection Technology of CH4,O433.1
- Photoacoustic spectroscopy study of superconducting materials in the liquid nitrogen temperature,O511.4
- Photoacoustic spectroscopy study material in the liquid nitrogen temperature.,O433.1
- Depth Profiling of Polymer Layered Composite Materials Using Rapid-and Step-scan Phase Modulation Fourier Transform Infrared Photoacoustic Spectroscopy,TB332
- Study on Fault Forecast and Diagnosis of Power Transformer Based on Dissolved Gas in Oil Analysis,TM411
- Chaotic Detection Method on Transformer Oil-dissolved Gas Photoacoustic Signal and Analyzing the Influential Factors,TM404
- Flat conductor parts remote field eddy current testing system research and design,TH878
- Exhaled ammonia Photoacoustic Spectroscopy Detection Technology,R692.5
- Preparation of Ordered Porous Structure Nano-TiO2 Thin Filmand Study on Its Optical Properties,TB383.2
- Study of TiO2 and ZnO Nanomaterials Prepared Via Ultrasonic Irradiation,TB383.1
- Based photoacoustic spectroscopy measure the water content in oil technology research,TP274
- Study on Detection Characteristics of Trace Acetylene in Transformer Oil-dissolved Gas Based on Photoacoustic Spectroscopy,TM404
- Photoacoustic spectroscopy based on Power Transformer Fault Detection System,TM41
- The CO2 Laser Based Photoacoustic Spectrometer and It’s biological Application,TH744.1
- Derivative photoacoustic spectroscopy and its application,O433
- Based on embedded digital lock-in amplifier TMS320C6701EVM,TN722
- Vibrating sample magnetometer data acquisition and control system development,TP274.4
CLC: > Industrial Technology > Electrotechnical > Transformers, converters and reactors > General issues
© 2012 www.DissertationTopic.Net Mobile
|