Dissertation > Excellent graduate degree dissertation topics show

A Comparison of the TruviewTM EVO2 Laryngoscope with the Macintosh Laryngoscope in Patients with Cervical Vertebral Diseases

Author: DuJianEr
Tutor: DengXiaoMing;LiJinBao;HouJiong;XiongYuanChang;ZhuWenZhong
School: Second Military Medical University
Course: Anesthesiology
Keywords: equipment TruviewTM EVO2 laryngoscope equipment Macintosh laryngoscope laryngoscopy cervical vertebra ankylosing spondylitis difficult airway
CLC: R614
Type: Master's thesis
Year: 2008
Downloads: 58
Quote: 0
Read: Download Dissertation

Abstract


Part 1:A comparison of the TruviewTM EVO2 laryngoscope with the Macintosh laryngoscope in patients scheduled for cervical vertebral surgeryObjective:The aim of this study was to prospectively compare laryngoscopy and intubation of Truview laryngoscope with that of Macintosh laryngoscope in patients scheduled for cervical vertebral surgery.Methods:One hundred patients scheduled for elective cervical vertebral surgery were enrolled in this randomised crossover study.After induction,the Macintosh laryngoscope and Truview laryngoscope were used in turn for direct laryngoscopy.The order of laryngoscope used was randomized by a random table list.The view of glottis at laryngoscopy was scored according to the Cormack-Lehane(C/L) grading criteria.The trachea was intubated after the second grading at laryngoscopy was completed.Relevant parameters were recorded,including demographics,airway assessment features(BMI, mouth opening,thyromental distance,Mallampati oropharyngeal scale,neck movement), C/L grade,the time to intubation(TTI),difficult laryngoscopy and related complications.Results:Of the 100 patients,34 had the same C/L grade score with both laryngoscopes.Of the remaining patients,64 showed improvement and 2 showed deterioration in C/L grade when the Truview laryngoscope was used compared to the Macintosh laryngoscope (Wilcoxon test,P<0.001).The proportion of difficult laryngoscopy was 5%obtained with the Truview laryngoscope,and was significantly lower than 28%with the Macintosh laryngoscope(McNemar test,P<0.001).Of the 100 patients,only 2 patients in Macintosh group required more than one attempt at intubation(two attempts) and were not included in the final TTI analysis.The TTI(28.6±9.0 s )in Macintosh group was significantly lower than that(33.4±8.6 s) in Truview group(independent-samples t test,P=0.008, 95%CI 1.3~8.3).There were significant association between airway assessment features and C/L grade(Spearman test,P<0.05).2 patients had a small cut on the lips and 3 patients had slight sore throat.Conclusion:The TruviewTM EVO2 laryngoscope could give a better glottic view and easier intubation than those by Macintosh laryngoscope in patients scheduled for cervical vertebral surgery.Part 2:A comparison of the TruviewTM EVO2 laryngoscope with the Macintosh laryngoscope in patients with ankylosing spondylitisObjective:The aim of this study was to prospectively compare laryngoscopy and intubation of Truview laryngoscope with that of Macintosh laryngoscope in patients with ankylosing spondylitis.Methods:32 patients with ankylosing spondylitis who presenting for hip replacement surgery were chosen to undergo tracheal intubation by Truview laryngoscope.Following induction, all patients underwent an intial direct laryngoscopy by Macintosh laryngoscope.After intial laryngoscopy,positive pressure ventilation was continued using a facemask and then laryngoscopy and tracheal intubation was performed by Truview laryngoscope.The tracheal intubation would be performed directly by fibreoptic bronchoscope if the view of glottis with Truview laryngoscopy was C/L gradeⅣor trachea could not be intubated successfully within three intubation attempts by Truview laryngoscope.Recorded relevant parameters included demographics,airway assessment features,C/L grade,difficult laryngoscopy,difficult intubation and related complications.Results:The preoperative airway assessment features of 32 patients included:Mallapati scoreⅢ~Ⅳ71.9%,mouth opening<3.5cm 21.9%,thyromental distance< 6.5cm 53.1%,neck movement<90°100%,neck movement < 30°43.7%.Of the 32 patients,5 patients had the same C/L grade scoreⅣwith both laryngoscopes,and remaining 27 patients showed improvement in C/L grade with Yruview laryngoscope compared to the Macintosh laryngoscope(Wilcoxon test,P<0.001).There was significant statistic difference in difficult laryngoscopy between Macintosh laryngoscope(81.3%) and Truview laryngoscope(37.5%)(McNemar test,P<0.001).There was significant difference in difficult intubation between Macintosh laryngoscope(56.2%) and Truview laryngoscope (25%)(McNemar test,P<0.001).There were significant association between airway assessment features and C/L grade(Spearman test,P<0.001).9 patients(28.1%) suffered slight sore throat and 3 patient(9.4%) suffered slight soft tissue damage,but all healed in next day.Conclusion:The TruviewTM EVO2 laryngoscope could give a better glottic view and easier intubation than those by Macintosh laryngoscope in patients with ankylosing spondylitis who might expect difficult intubation,and might have potential advantages for managing difficult airway.

Related Dissertations

  1. Multi-Objective Regulation and Protection Control for Ship Steam Power Equipment,U664.11
  2. Design and Implementation of the weapons and equipment information management system,TP311.52
  3. Military exercises in the Corps of Engineers engineering equipment maintenance to protect the allocation of resources,E251.2
  4. Design of Testing Equipment for Electronic Products,TN06
  5. Studies on the Process and Facilities of Straw-Excrement Ferment Technology for Biogas and Biological-Organic Compound Fertilizer,S141
  6. Ways and means of military equipment management of cadres training,E251.1
  7. The Workshop Process Design of the Soy Poly-peptides,TS214.2
  8. Research on Safety Production of Shenzhen Power Supply Bureau,TM08
  9. Single-segment Transpedicular Vertebral Osteotomyon the Top of Kyphosis Combined with Screw Internal Fixationfor Correction of Thoracolumbar Spine Kyphosis in Ankylosing Spondylitis,R687.3
  10. The Effectiveness of Dexmedetomidine Infusion in Blind Nasotracheal Intubation,R614
  11. Malawi national table tennis Current Situation and Analysis,G846
  12. China gym fitness equipment status and standardization of terminology of exploration and research,G812.0
  13. Incubation equipment intelligent control system design,TP273.5
  14. Direct laryngoscopy slowing stress response of the cardiovascular system : general anesthesia with fentanyl , lidocaine and placebo controlled study,R614
  15. Study on the Development Strategy of the Western Heavy Industry Co.LTD under the Promoting of the New Energy Equipment Industry,F426.4
  16. Research on Orbit-holding Traveling Mechanism of Pipeline Girth Welds Scanning Equipment,TE973.3
  17. Preliminary Investigation on the Historical Value of the Records of the Border Defense Council of the Joseon Dynasty,K312
  18. Institute & Implement on Chinese Market Strategy of Votech,F426.4
  19. Design and Development of ERP Equipment Manage System of Benxi Iron and Steel Company,TP311.52
  20. Design and Implementation of ERP Production Management System in BXSteel Mining Equipment Plant,TP311.52
  21. Research of Point Check & Periodic Maintenance Equipment Management System in HSM Project Dept. of TongHua Steel Group,TG338

CLC: > Medicine, health > Surgery > Surgical operation > Anesthesiology
© 2012 www.DissertationTopic.Net  Mobile