Dissertation > Excellent graduate degree dissertation topics show

Synthesis Spplication of Multi-Slice CT Three-dimensional Reconstruction in Ear Disease Diagnosis

Author: LiuZuo
Tutor: TianJianMing
School: Second Military Medical University
Course: Medical Imaging and Nuclear Medicine
Keywords: MSCT ear disease 3D reconstruction
CLC: R816.96
Type: Master's thesis
Year: 2008
Downloads: 95
Quote: 0
Read: Download Dissertation

Abstract


Objective:Research the utility of three-dimensional reconstruction of Multi-slice Spiral CT(including MPR,SSD,MIP,VRT) for demonstration and diagnosis of ear pathological change.To tests the normal group and ear disease group by the above method and Multi-slice Spiral CT scanning. Separately carries on the diagnosis with kinds of inspection technology,take the final pathology result as the reference,compare accurate rate and the sensitivity of these diagnosis methods.Discussing its application value in diagnosis,appraising the curative effect after the treatment and the follow-up visit.Method:Collect kinds of cases,normal group has 84ears,inner ear with congenital malformation group has 10ears,chronic tympanitis has 41 ears.All groups have adopted the 64-slice CT scanner axial scan.Subjects are supine, baseline is the canthomeatal line,scanning range from the external auditory foramen lower edge to the os petrosum upper edge,thickness is 0.75mm, collimator width is 0.75mm.After scanning,in 3D control panel,along the long axis of bone in free model,axial images and coronal images are post-processed with MPR,MIP,SSD and VRT.Valuing the advantages and disadvantages of reconstruction method for showing the inner ear disease.Results:1、The correct rate is 100%,which MPR,MIP,SSD,VRT for diagnosis the destroys of head of malleus,the handle of malleus,the body of incus; the correct rate is 100%for diagnosis the destroys of the ossicular chain.2、Demonstration rate of ear hammer,the anvil and the stirrup bone is 100%when MIP is used in no pathological change group,although cannot demonstrate stirrup instep,but the integrity of ossicular chain can be decided.3、SSD can show structure of the middle ear clearly,including roof of tympanum, sigmoid sinus,bone wall,scutal shield and aditus ad antrum.Facial nerve pore, labyrinthus and stirrup are can’t show clearly.4、VRT can show structure of the inner ear clearly,including base of cochlea,vestibule,bulb and common crus of canalis semicirculares,fossula rotunda,fenestra ovalis.Top and center of cochlea are can’t show clearly.Conclusion:Malleus,incus,a hammer,incudomallear articulation, incudostapedial articulation can be demonstrated vividly.Facial nerve can be also show clearly in anteroposterior axes oblique position.A powerful image basis can be provided for surgery.Providing a basis for the diagnosis of tympanitis、inner ear malformation and implanting of artificial cochlea.Three-dimensional reconstruction of Multislice CT has important clinical value in diagnosis and program development of facial paralysis caused by the temporal bone fracture.Three-dimensional reconstruction of Multislice CT can be used as a routine examination of middle ear disease

Related Dissertations

  1. 3D Visualization Research of Medicial Ultrasound Image,TP391.41
  2. The Research of Three-Dimensional Surface Reconstruction Algorithm Based on CT Image,TP391.41
  3. 3D Laser Scanning Technology Application in the Field of Protection for Petroglyph,K854
  4. Variation Study of Pulmonary Vein by Multi-Slice Spiral Computed Tomography,R816.2
  5. The System for Engineering Drawing Vectoring and 3D Reconstruction,TP391.41
  6. Research on the Three-dimensional Reconstruction of Small Size Cavity of Mold,TP391.41
  7. Underwater 3D Reconstruction Based on Binocular Stereo Vision,TP391.41
  8. Application of Geometric Algebra for 3D Reconstruction in Computer Vision,TP391.41
  9. The PRRS Attenuated Vaccine Immunity Effect Appraises and Oderman-1 to Its Immunity Effect Influence,S858.28
  10. The Relationship between the Concentration of Gibberellic Acid in Rice Panicle at the Heading Stage and the Panicle Diseases,S435.11
  11. The Technique of 3D Reconstruction from 2D Frame Sequences,TP391.41
  12. Variations of the Antibody Levels of Pigs after Immunized with CSF、PRRS and FMD Vaccines Singly and Multiplly,S858.28
  13. MSCT cirrhosis quantitative analysis of serum NO, NOS and TNF-α correlation,R575.2
  14. A Research for Algorithm of Three-Dimention Reconstruction,TP391.41
  15. Computer Reconstruction of 3D Microstructure for a P/M Alloy,TF125
  16. The Study of Sex Determination of Sacral Basis in CT 3D Reconstruction,D919.4
  17. Moving Object Detection Research in Dynamic Scenes,TP391.41
  18. MSCT Evaluation the Severity of Acute Pancreatitis with Liver Damage Correlation Study,R576
  19. Pathological Characteristics Studies on Fatal PRRS,S858.28
  20. Diagnostic Value of 18F-FDG PET/CT in the Preoperative Advanced Gastric Carcinoma Comparing with MS Compute Tomography,R735.2
  21. 3D Reconstruction Based on Nonparallel Two-eye System,TP391.41

CLC: > Medicine, health > Of Medical > Radiation Medicine > Each location and course of disease X - ray diagnosis and therapy > Department of Otolaryngology,
© 2012 www.DissertationTopic.Net  Mobile