Lightning is one of phenomena of discharge which is common in nature. In recent years, lightning stroke is one of the important causes of the accidents that occur on trans-mission lines. With the increase of voltage grade of transmission line, incidents caused by backflash can not be ignored. Therefore, exactly evaluating lightning-withstanding level of transmission line is especially important for system service and stable operation.When the first stroke of a flash terminates at the top of a tower, a wave travels down the tower and out on the overhead ground wires, making the waveshapes of the voltage across the insulation significantly differs from the standard 1.2/50μs. Research shows flash-over characteristics of insulation under non-standard waver is different from the standard wave. It’s necessary to build a criterion for insulation flashover under non-standard wave.Several methods of estimating the insulation flashover are in use today. In general, these methods can be divided into those that attempt to model directly the breakdown proc-ess and those that are derived from the breakdown process. Leader progression model which used by CIGRE is one of those methods. A new criterion derived from the leader progression model is introduced here, for it based on the breakdown process. Applying this criterion, the lightning flashover performance of the insulators for 500kV and 1000kV transmission lines are calculated here, the calculation results indicate that the criterion is reasonable under non-standard wave.Also there is a model of numerical calculation of criterion model is presented, which can be easily linked to EMTP by MODELS language. And a 1000kV double-circuit trans-mission line is taken for instance to evaluate the influence of the criterion model for insula-tion flashover proposed in this thesis on the result of the calculation of lightning-withstand ability. It is obtained that the criterion model proposed in this thesis is reasonable to be used in lightning protection calculation.
|
Related Dissertations
- Research on Single-phase to Ground Fault Isolation Method of Distribution Network,TM862
- The Research and Implement of Multi-point MOA on-line Monitoring System Based on Wireless,TM862
- 10kV grounding resistor Thermal Stability,TM862
- New arc and overvoltage protection device developed,TM862
- With a small current grounding fault line selection function distribution lines monitoring device design and research,TM862
- Based on morphological analysis of small current grounding fault identification technology and engineering,TM862
- Protection of 20kV line to ground,TM862
- The Simulation of Single-phase Earthed Fault in Small Current System and Multi-information Line Selection Study,TM862
- Research on Lightning Protection Measures for 35kV Power System of Dexing Copper Mine,TM862
- Distribution Network Fault Data Acquisition and Processing Based on FPGA,TM862
- Design and Application for Jiangxi 200kV Transmission Line Towers Grounding Device,TM862
- Design and Implementation of the lightning protection business management system based on WEB technology,TM862
- Design and implementation of standardized management information system in mine,TM862
- Intelligent method of resonance grounding system fault line selection,TM862
- Transmission line lightning fault identification and location of new methods,TM862
- Grid ground engineering applications,TM862
- The Technology Analysis of Earth Fault Protection in Non-Solid Grounded System,TM862
- Discussion of Four High-Voltage Transmission Lines with the Tower of Lightning Prevention,TM862
- Research on Line Betection for Single-phase Arc’s Earthing Faultin Neutral Point Non-effective Grounded System,TM862
- A Faulty Line Selection Study and the Corresponding Equipment of Non-effectively Grounded System Single-phase-to-ground Fault Based on Integrative Methods,TM862
- Theoretical Study On Impact Impedance Of Grounding Grid,TM862
CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage protection devices
© 2012 www.DissertationTopic.Net Mobile
|