Dissertation > Excellent graduate degree dissertation topics show

Research on Heat Carrying Capacity of Water in Lake-Water Source Heat Pump System

Author: WuHao
Tutor: FuXiangZuo
School: Chongqing University
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: surface-water source heat pump water temperature distribution thermal stratification water temperature model heat capacity
CLC: TU833
Type: Master's thesis
Year: 2008
Downloads: 242
Quote: 12
Read: Download Dissertation

Abstract


With the economic and technological development as well as energy and environmental issues have become increasingly prominent, the surface-water source heat pump (SWHP) draws more and more public attention. The Yangtze River district and the south of China abound with water resources, the surface-water source heat pump possess great significance. SWHP need appropriate water source, and there are heat load limit for one lake or reservoir. This paper focused on the research that the lake’s or reservoir’s highest heat capacity.The natural water temperature distribution characteristics of the lakes and reservoirs are studied in the paper: the temperature of the lake-water which the depth is greater than 4m is shown clear signs of thermal stratification in late spring, summer, early and mid autumn, but in the winter and early spring, the entire lake and reservoir water temperature distribution is uniform; the temperature of the lake-water which the depth is less than 3m is equally distributed during the whole year, and is non-thermal stratification, meanwhile, the water temperature is impacted by air meteorological parameters.In this paper, mathematical model of the natural water temperature distribution for the thermal stratification lakes and reservoirs is established, and utilized a large number of measured data to test the accuracy of the model and the reasonableness of parameters. On the basis of the natural water temperature model, the water temperature model when loading heat load is established by addition source item into equations, at the same time, the paper uses measured data of lake-water source heat pump air-conditioning system of People’s Hospital in Kai County, Chongqing, to test the correctness of the water temperature model when loading heat load and the water flow model.By solving the water temperature model when loading heat load and the water flow model to calculate water’s highest heat capacity. Takeing Chongqing in the areas cold in winter and hot in summer as an example calculated the lake-water’s highest heat capacity with different temperature and different depth. Based on the data calculated, regressed the relationship between lake-water’s highest heat capacity (w/m2) and lake’s average depth (m) and lake-water’s average temperature (℃). According to this, get the relationship between lake-water’s highest air-conditioning cool load (w/m2), lake’s average depth (m), lake-water’s average temperature (℃) and the units’EER. With regards to drainage, there are two ways, one way is the drainage was drained to the layer which the temperature is as same as drainage’s temperature, and the other way is the drainage was drained to the surface layer. In this paper, the water temperatures at bottom in these two ways was compared, and conclude that the first way is better than the second one. Suggest that the first way is a better approach in practical project.At last, studied the water temperature recovery, concluded that even if the water bears the highest heat load in summer, its temperature can recover to the level under natural conditions before the beginning of heating period.

Related Dissertations

  1. Integrated Design of Residence & Airflow Distribution System Based on the Principles of Underfloor Air Distribution System,TU831
  2. Research on Thermal Physical Parameters of Asphalt Mixture,U414
  3. Thermochemistry on the Coordination Behavior of 2-pyrazinecarboxylic Acid with Metallic Elements.,O621.13
  4. Research on Dynamic Character of Open-loop System Surface Water Source Heat Pump System,TU831.3
  5. The Optimal Study on Operational Control of Surface Water Source Heat Pump,TU831.3
  6. The Analysis of the Ground Source Heat Pump System Based on the Thermo-Economic,TU833
  7. Calorimetrical Measurement of Protein Adsorption on Hydrophobic Interaction Adsorbent,O629.73
  8. The Research of Energy Measurement and Billing of Surface Water Source Heat Pump,TU831.6
  9. Research and Design of the Express Calorimeter,TH81
  10. Thermal properties of thin film materials and testing,O484.4
  11. Research on Preparationand Properties of Phase Change Mortar,TB34
  12. Feasibility Analysis of Using Surface Water Source Heat Pump Used in Public Building Air Condition in Dongguan Area,TU831
  13. Estimation of the Heat Capacity of Supercooled Solute and Related Thermodynamic Properties from Solubility Measurements,TQ013.1
  14. Vertical heat exchanger heat transfer performance of,TU831.4
  15. Effect of Lake-Water Source Heat Pump System on Water Environmental Quality,TU831
  16. Mezzanine indirect heat exchanger tank natural circulation type solar water heater system, Tablet Thermal Performance Study,S214.2
  17. Numerical Study on Hydrodynamic and Water Quality in Liao River Basin,X824
  18. Calculation Analysis of Maximum Cooling Capacity of Small Water Body,TU831.2
  19. Study of Several Key Issues about Surface-Water-Source Heat Pump,TU831
  20. Study on Suitability for Comprehensive Evaluation and Planning about Surface Water Source Heat Pump Systems,TU831
  21. Study on Heat Exchange Performance of Close-loop Surface Water Sources Heat Pump,TU831

CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Heating