Abstract
|
Minimal invasive vascular surgery (MIVS) is a kind of new medical technology, which uses catheter to perform operations. Operations like this have many advantages, such as short recovery time; less tissue damages incurred from incisions and so on. In recent years, it is becoming more and more widespread.In traditional methods of catheterization, the catheter is operated by the doctor directly. However, the catheter operated in this way has many disadvantages, such as difficult guiding, steep demand for manipulative skill and injuring blood vessels. For a better catheterization, this paper plans to develop a new transporting system for the catheter used in MIVS to take the place of the traditional catheterization.In the first place, the structural analysis and designing scheme of the transporting system are given according to the system functional demands. Two kinds of designing schemes of transporting devices, the continuous transporting device and the relay transporting devices are given. Three dimensional entity models of the devices are established to detect interference through kinematic analysis. The stress analysis and strength verification are provided for the typical parts of the devices. Subsequently, improvement and optimization of the structure of the continuous transporting devices are carried out according to the parameters.In the next place, this thesis focuses on the structures of the hardware and software in motion controlling system. According to the task characteristics of the MIVS catheter transporting system, Heterogeneous master-slave control scheme is adopted. The hardware platforms which base on motion controller and 3DOF handle are built. The controlling software is designed in VC++ environment to realize the controlling functions.In addition, a tactical sensor is installed in the transporting system to feedback the invasive force. The circuit board is designed, and the hardware platforms which base on Advantech Data Acquisition Card are built in order to process the force signal. Then the software platforms make the master-handle have the feeling of the feedback force. Meanwhile, a force protecting function is settled to insure the safety of the surgery. Finally, the continuous transporting device and the controlling systems are combined to perform the MIVS operation. Meanwhile, the feasibilities of the system are verified through experiments.
|
Related Dissertations
- Hypertensive patients with atrial fibrillation electro-anatomical characteristics on impact,R541.75
- Minimally invasive surgical robotic systems development master manipulator,TP242
- The master-slave control hydraulic excavator Research,TU621
- Overweight Patients with Paroxysmal Atrial Fibrillation Might Benefit from Induction Strategies after Pulmonary Vein Isolation,R541.75
- Break Window exclusion combine cutting seton extended catheter drainage treatment of complex anal fistula security , multi-center clinical study,R657.1
- Design and Control Strategy of A Force-feedback Master Manipulator,TP242
- Research on Shared Control Method of Virtual Guide Oriented to Teleoperation,TP242.2
- Research on Deformation Technique of Human Soft Tissue in Virtual Surgery,TP391.41
- Research on the Movement Control of the Active Catheter Actuated by Shape Memory Alloy,TP242.3
- Researched on Simulation System of Neuron-Vascular Interventional Radiology Procedures,R743.3
- Research on Virtual Grasp Based on Dexterous Hand,TP391.9
- Research of the Assembly Process in Augmented Reality Mechanical Assembly Environment,TP391.41
- Retrospective Study of Idiopathic Ventricular Tachycardia Treated by Radiofrequency Catheter Ablation,R541.7
- Research and Relevant Design of Vibrating Ring MEMS Gyroscope,TN966
- The Impact of Age on the Electroanatomical Characteristics and Clinical Outcome after Catheter Ablation of Patients with Atrial Fibrillation,R541.75
- Clinical Observation of Postoperative Local Anesthetic Analgesia with Ropivacaine,R614
- Pyogenic Ventriculitis Associated with Cerebral Ventricular Empyema: A Case Report,R742.9
- Research of Correlative Factors in Durative Staxis and Phlebitis of Acute Leukemia Patients with PICC,R472
- Preparation and Analysis of the Bacteriostasis Effect of Nano-Ag-SiO2 Anti-infective Catheters,R472
- Acute deep venous thrombosis of central catheter thrombolysis experimental study of contact,R543
CLC: > Industrial Technology > Machinery and Instrument Industry > Instruments, meters > Medical and health devices > Other medical devices
© 2012 www.DissertationTopic.Net Mobile
|