Dissertation > Excellent graduate degree dissertation topics show
Theoretical and experimental study of the large dynamic range scan converter tube
Author: LiuHongBo
Tutor: ZhaoBaoSheng
School: Xi'an Optics and Fine Mechanics
Course: Physical Electronics
Keywords: Scan converter tube Dynamic range Time resolution Space charge effect Electro-optical systems
CLC: TN141
Type: Master's thesis
Year: 2004
Downloads: 124
Quote: 0
Read: Download Dissertation
Abstract
|
Dynamic range and temporal resolution of the scanned image converter tube is conflicting , the goal of this thesis is to develop a higher temporal resolution while maintaining at the same time , with a large dynamic range scan converter tubes for inertial confinement fusion the diagnosis of ultrafast processes provide a powerful tool . Analysis of the impact of the image converter tube time response characteristics of a variety of factors , such as photoelectron early energy dispersion ; transit time dispersion , as well as many non-linear factors affect the dynamic range of the image converter tube , such as the space-charge effect on the photoemission ; the photocathode emission electron pulse transition process ; phosphor screen current saturation effects . Fully optimized design guidelines , to determine the time - spatial modulation transfer function for the evaluation of the principle of the design of the Monte-Carlo method for the calculation means route . In the key right the influence time resolution and dynamic range of the common physical mechanisms - the space charge effect based on the analysis , to abandon the usual axially symmetrical electron-optical system , using a special design of the electron optics plane focusing cylindrical lens , shortening the focus region axial dimension, while appropriately increasing the voltage between the photoelectron in the focus region of the transit -time is reduced , thereby suppressing the role of the space-charge effect , thereby improving the dynamic range . The scanned image converter tube significantly characterized by small size , compact structure . Tube full length 190mm, focus area length 65mm deflection sensitivity 40mm/kV , time distortion . The time resolution of the theoretical design 300fs, static spatial resolution than 601p/mm . Electro-optical design based on the completion of a large dynamic range scan converter tube structure design and machining , and developed a large dynamic range scan converter tube . And the static experiments, the ideal experimental results .
|
Related Dissertations
- Study and Evaluation of the Glare for LED Lighting Fixture,TM923.34
- Study on the High Dynamic Range Image Composition Algorithms Based on Davinci Platform,TP391.41
- Volumetric Quantization and Transfer Function Design Based on Feature Enhancements,TP391.41
- Stratification and energy optimization based on the brightness of high dynamic range image tone mapping technology research,TP391.41
- Endoscopic laser confocal fluorescence microscopy imaging technology adaptive,TP391.41
- Continuously adjustable temperature control precision large range of fiber optic delay line,TN929.11
- Research on Digital Video Enhacement Technique Based on Target,TP391.41
- Research on the Approach of HDR Vision and Its Implementation on FPGA,TP391.41
- Spread Spectrum Digital receiver onboard monitoring key technology research,TN914.42
- Ultra-high Frequency RFID Baseband Signal Processing and Phase Estimation,TN911.7
- Wide Dynamic Range CMOS Image Sensor with In-Pixel Double-Exposure and Synthesis,TP212
- High Dynamic Range Image Generated Based on Multi-Exposure Images,TP391.41
- VHF Frequency-hopping Radio Receiver Front-end Research and Implementation,TN924
- Technology on Design and Implementation of Pulsed Coherent Radar Digital Receiver,TN957.5
- Adaptive High Dynamic Range CCD Imaging System,TP391.41
- Large dynamic broadband microwave receiver channel design,TN911.5
- Multiple exposure based image enhancement algorithm,TP391.41
- High dynamic range image tone mapping algorithms and video enhancement technology,TP391.41
- Research on Demodulation Algorithm of PCM/FM with Large Dynamic Range Doppler Frequency Shift,TN911.72
- Chirped pulse amplification system SNR enhancement technology research,TN722
- Simulation of Enhanced Display Based on Visual Perception of Human Eye,TP391.41
CLC: > Industrial Technology > Radio electronics, telecommunications technology > Vacuum Electronics > Electron beam devices,X-ray tube, cathode ray tubes > Display
© 2012 www.DissertationTopic.Net Mobile
|