Abstract
|
The analytical method of ion-selective electrode is direct and nondestructive, it has simple structure, simple handled, wide potentiometric response range, highly sensitive, it can rapidly determine sample continuously, so it has been applied in most departments of industry and agriculture and science technology. Design, synthsis and application of highly selective and sensitive neutral carriers are main research subjects in the ion-selective electrode studies. Recently, study on ion-selective electrodes with anti-Hofmeister selectivity pattern is an important and interesting project in the fields of electrochemistry and electroanalytical chemistry. This thesis focuses on seeking design and synthsis of novel metallic complex and basic studies on solvent polymeric membrane(SPM) anion-selective electrodes containing the novel metallic complex. The electrodes can be applied to practice sample analysis.Part I of this thesis deals with design of neutral carrier for solvent polymeric membrane thiocyanate electrode with high selectivity.1. Bis-[(3-ferrocenyl)-(2-crotonic acid)] metallic complex of copper(II), cobalt(II) and riickel(II) were synthesized. We firstly study the potentiometric response characteristics of the anion-selective PVC membrane electrode based on these ferrocene derivatives as neutral carrier, and found that the electrode based on bis-[(3-ferrocenyl)-(2-crotonic acid)] copper(II) complex [Cu(II)-BFCA] as neutral carrier demonstrates high selectivity towards thiocyanate ion and anti-Hofmeister selectivity sequence in following order: SCN-’> I-> C1O4-> Sal-> Br-> NO3-> Cl-NO2- > SO3- > SO42-. The response mechanism is discussed in view of the UVspectroscopy and the A.C. impedance technique. The electrode was successfully applied to the determination of thiocyanate ion in actual sample.2. Dimethylaminobenzaldehyde-(o-aminobenzoic acid) metallic complexes of Cu(II), Ni(II), Co(II) and Zn(II) were synthesized. We firstly study the potentiometric response characteristics of the anion-selective PVC membrane electrode based on these metallic complexes as neutral carrier, and found that the electrode based on dimethylaminobenzaldehyde-(o-aminobenzoic acid) copper(II) complex [Cu(II)-DMABABA] as neutral carrier demonstrates high selectivity towards thiocyanate ion and anti-Hofmeister selectivity sequence in following order: SCN > r > Sal" > C1O4" > NO2" > Br > Cl" > NO3 > SO32 > SO42 > H2PO4. The response mechanism is discussed in view of the UV spectroscopy and the A.C. impedance technique. The electrode was successfully applied to the determination of thiocyanate ion in actual sample.Part II of this thesis deals with design of neutral carrier for solvent polymeric membrane iodide electrode with high selectivity.1. yV,./V-bis-(acetylferrocene)-ethylenediamine metallic complexes of Hg(II), Cu(II) and Zn(II) were synthesized. We firstly study the potentiometric response characteristics of the anion-selective PVC membrane electrode based on these metallic complexes as neutral carrier, and found that the electrode based on 7V,A^-bis-(acetylferrocene)-ethylenediamine mercury(II) complex [Hg(II)-BAFEDA] as neutral carrier demonstrates high selectivity towards iodide ion and anti-Hofmeister selectivity sequence in following order: I" > Br > SCN > C1O4" > NO2" > Cl" > SO32 > NO3" > SO42". The response mechanism is discussed in view of the UV spectroscopy technique. The electrode was successfully applied to the determination of iodide ion in actual sample.2. #,A^-bis-(dimethylaminobenzaldehyde)-glycine metallic complexes of Co(II), Ni(II) and Cu(II) were synthesized. We firstly study the potentiometric response characteristics of the anion-selective PVC membrane electrode based on these
|
Related Dissertations
- Imidazolium ionic liquids selective electrode and its research activity coefficient,O646
- A Design of Portable Testing System for Inferring of the Time of Death by Detecting the Concentration of Potassium and Sodium Ions in Vitreous Humor,D919
- The Confirmation and Application of the Function of Fluoride ISE after Being Activated Improvement,O657.1
- The Design and Implementation of A Water Hardness Online Detector,O657.1
- New Methods for Determination of Hydrogen Peroxide,R115
- Research on the Detection Sensor for Total Phosphorus in Environment Water,TP212
- Studies on Metal Ion-Selective Electrodes and Carbon Nanotubes Modified Electrodes: Application in Environmental Samples,O657.1
- Laboratory Study on Systemic Fluoride Intake and Urine Fluoride Content of Children in Kunming,R788
- Molecularly imprinted polymer synthesis, characterization and application,O631.3
- Research and Design of Automatic Measuring Device for Boiler Water Hardness,TK223.7
- Electrochemical and Optical Sensors Based on Polymer Composites and Selective Probes,TP212.2
- Research of the Analysis Method for Sixteen Elements in the Rough-wrought and Sintered Import Materials Containing Copper,TF046.4
- Indole -containing BODIPY novel asymmetric synthesis and application of fluorescent probes,O626
- High-performance 16-bit MCU-based Electrolyte Analyzer Design,TH832.2
- Study of the Clinical Electrolyte Analyzer Based on ATmega64,TH832.2
- Chromium Eelectrode Fabrication and Measurement of Cr3+ and H+ Fluxes Along Leersia Hexandra Swartz Roots,O657.1
- Study on Ion-selective Electrode Based on Schiff Bases and Their Complex as Ionophore,O657.1
- Research on Determination Method for the Dissolvable Sulfide in Oilfields Produced Water,X832
- Studies and Application of Metal Ion-Selective Electrodes,O657.1
- Studies on PVC Membrane Ion-Selective Electrodes Based on Neutral Carriers and Amperometric Immunosensors Based on Layer-by-Layer Self-Assembly Technique,TP212.2
- Purification of Dihydromyricetin from Tengcha and Preliminary Study on Its Metallic Complexes,S571.1
CLC: > Mathematical sciences and chemical > Chemistry > Analytical Chemistry > Instrument analysis ( physics and physical chemistry ) > Electrochemical analysis
© 2012 www.DissertationTopic.Net Mobile
|