The Location of Rectus Pulley in High Myopia by Dynamic MRI

Author: FanZhaoShan
Tutor: WangLiHua
School: Shandong University
Course: Ophthalmology
Keywords: Axial high myopia Eye movement Extraocular muscles Magnetic resonance imaging Rectus Pulley
CLC: R778.11
Type: Master's thesis
Year: 2005
Downloads: 27
Quote: 0
Read: Download Dissertation

Abstract


Purposes MRI study axial high myopia the four rectus Pulley function position on axial high myopia eye movement disorders secondary cause. The method of axial high myopia in 14 cases ( 22 ) is divided into A, B groups based on eye refraction, axial length , and the presence or absence of eye movement is limited . Eye movement disorders ; Group A and Group B limited eye movement . Eye in primary position and on the turn , the next turn , internal rotation , external rotation bit coronal magnetic resonance scan . To establish a three-dimensional coordinate system for the origin to the center of the eye , using Scion Image medical image measurement software to measure vertical eye rotation at all levels when horizontal rectus eye level rotates vertical rectus cross-section of the center of mass . All levels MRI images before and after the order arranged and connected to the cross-section of the center of mass of each rectus namely the rectus pathway . Establish linear regression equation based on all levels rectus cross-section of the center of mass coordinates value obtained using the statistical software SPSS11.5 eye Tilt , the lateral rectus pathways rotation and eye level when the inferior rectus pathways linear regression curve the largest slope changes , namely rectus Pulley sites , compare group A , group B , normal control group . Results of the A group and the normal control group four rectus pulley sites showed no significant differences ( P gt ; 0.05) ; B group and normal control group rectus (MR), on rectus ( SR ) , inferior rectus ( IR ) sites of the rectus pulley difference no statistically significant difference ( P gt ; 0.05 ) , lateral rectus pulley comparison sites have a very significant difference ( P lt ; 0.01) , lateral rectus ( LR ) pulley sites significantly inferior temporal shift ; A group and B group , rectus , superior rectus , inferior rectus three rectus

Related Dissertations

  1. MRI Guoded Experimental Cryoablation of Rabbit’s Sciatic Nerve for MRI and Pathology Contrast Study,R445.2
  2. The Clinic Value of Diffusion Weighted Whole Body Imaging with Background Body Signal Suppression (DWIBS) Compared with hPET/CT,R445.2
  3. A Volumetric Study of External Capsule, Extreme Capsule and Inferior Frontal Gyrus White Matter in First-Episode Paranoid Schizophrenia,R749.3
  4. Healthy Chinese central olfactory structures related to MRI volume and olfactory function with age correlation,R445.2
  5. 3.0T BOLD MR techniques on acute unilateral ureteral obstruction of renal damage,R693.2
  6. 3.0T high-field magnetic resonance imaging of the central type lung cancer preliminary study,R734.2
  7. MR diffusion weighted imaging in Application Value of osteonecrosis,R681.8
  8. Comparative Study of Clicking Temporomandibular Joint Before and after Being Cured by MRI,R445.2
  9. Synthesis and Characterization of Two Novel Magnetic Resonance Imaging Contrast Agents,R914
  10. The Exploration and Application of MR Imaging in Patients with Lateral Epicondylitis of the Elbow,R681.8
  11. MR Imaging of Brain Glioma in Rat Model Using Transferrin-conjugated SPIONs as a Specific Contrast Agent,R739.4
  12. New Open MRI superconducting main magnet design,R318.6
  13. On the visual center clothing,J523.5
  14. Research on Eye Movement Evaluation of Celebrity Advertising Effect,F713.8
  15. Multi-Class Pattern Analysis on Human Brain MRI Dataset,TP391.41
  16. Artifacts of Magnetic Resonance Imaging Caused by Ni-Cr Alloy and Co-Cr Alloy in Prosthodontics,R783
  17. Imaging Study and Application of Inner Ear with Magnetic Resonance Hydrography Technique,R764
  18. Value of conventional MRI and diffusion-weighted imaging in the diagnosis of cholesteatoma,R764
  19. Diffusion Tensor Imaging Using 3.0T MR Scanner in Rat C6 Glioma Model and the Correlative Study of FA Value in Infiltrated Peritumoral Edema Tissue and AQP1,R739.4
  20. On High b Value DWI to Brain Glioma Marginal Zone,R739.4
  21. Arteriosclerotic leukoencephalopathy diffusion tensor imaging,R445.2

CLC: > Medicine, health > Ophthalmology > Eye dioptrics > Eye application dioptrics > Myopia
© 2012 www.DissertationTopic.Net  Mobile